Column E Logarithmic (Column E)

1. The exchanger duty is 480 kW and the required heater duty is 686 kW to account for losses. 2. Using the properties of Transcal N at 157°C, the mass flow rate required is calculated to be 14612 kg/hr. 3. With a heat capacity of 2.365 kJ/kg°C, inlet temperature of 167°C and outlet of 182°C, the heat load is 518400 kJ/hr, equivalent to 144 kW.

Uploaded by

syamsudin2006
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views7 pages

Column E Logarithmic (Column E)

1. The exchanger duty is 480 kW and the required heater duty is 686 kW to account for losses. 2. Using the properties of Transcal N at 157°C, the mass flow rate required is calculated to be 14612 kg/hr. 3. With a heat capacity of 2.365 kJ/kg°C, inlet temperature of 167°C and outlet of 182°C, the heat load is 518400 kJ/hr, equivalent to 144 kW.

Uploaded by

syamsudin2006
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 7

ln(P)=A+D*ln(T)

T VP ln(VP)
283 2.00E-05 -10.81978
323 4.50E-03 -5.403678
348 7.00E-02 -2.65926 A = -179.93
373 6.20E-01 -0.478036 D = 30.163
423 11.7 2.459589
473 410 6.016157
523 3200 8.070906 10
f(x) = 30.1631606059 ln(x) - 179.928531891
5 R² = 0.9869523237

0 Column E
250 300 350 400 450 500 550 Logarithmic
(Column E)
-5

-10

ln(P)=A+B/T
-15

T VP 1/T ln(VP)
10 283 2.00E-08 0.003534 -17.72753 A = 23.338
50 323 4.50E-06 0.003096 -12.31143 B = -11550
75 348 7.00E-05 0.002874 -9.567015
100 373 6.20E-04 0.002681 -7.385791
150 423 0.0117 0.002364 -4.448166
5
200 473 0.41 0.002114 -0.891598
250 523 3.2 0.001912 1.163151
0 f(x) = - 11550.1836977784x + 23.338394
0.0015 0.002
R² 0.0025 0.003 0.0035 0.004
= 0.9981117881
-5 Col
Line
(Co
-10

-15

-20
179.928531891

Column E
550 Logarithmic
(Column E)

1836977784x + 23.3383945449
3881
0.0035 0.004
Column F
Linear
(Column F)
mass rate= 1 kg/h
MW= 16.14
mol rate= 0.0619579 kmol/h
P= 1 atm standard condition
T= 15 oC standard condition
T (absolute) = 288 K
R= 8.205E-05 m3/atm/K/mol
V= 1.4640892 m3/h --> Sm3/h

V'= 51.664124 scfh = 0.0012 MMSCFD


Transcal N Heat Transfer Oil Property Predictor (Note 1,2,3)

Temperature: 157 C Note: 1. Accurate prediction is limited to temperatures between 180 and 320°C
2. Recommended maximum bulk fluid temperature for this product is 320°C
Predicted Properties: 3. Data Source: BP Lubricants, Transcal N Technical Data Sheet
4 Based on P&ID
Density 786.2 kg/m3 5 Assumption of burner efficiency 70%
Heat Capacity 2.365 kJ/kg.C 6 Refer to Exterran heater datasheet
Thermal Conductivity 0.123 W/m.C
Viscosity 1.836 cSt
1.444 cP
Vapour Pressure is 0.0295 kPa

Required Hot Oil Rate:

Hot oil distribution temperature (°C) 182


Hot oil return temperature (°C) 132

Exchanger duty (kW) 480 (Note 4)

Transcal N mass flow required (kg/hr) 14612 32146.12 lb/hr

Required duty on the heater/furnace (kW) 686 (Note 5)

Fuel gas heating value (kJ/kg) 49605.59 (Note 6)

Fuel gas required (kg/hr) 49.76398

Fuel gas required (MMSCFD) 0.0617


hot oil rate= 18.58633 m3/h

mass rate= 1 kg/h


MW= 16.14
mol rate= 0.0619579 kmol/h
P= 1 atm
T= 15 oC
T (absolute) = 288 K
R= 8.205E-05 m3/atm/K/mol
V= 1.4640892 m3/h --> Sm3/h

V'= 51.664124 scfh = 0.0012 MMSCFD

Fuel gas heating= 910.1 BTU/scf refer to Exterran datasheet


49605.593 kJ/kg
ALT CASE
mass rate 14612 kg/h
heat capacity= 2.365 kJ/kg/C
T in 167 oC
T out 182 oC
Q= 518400 kJ/h
144 kW