0% found this document useful (0 votes)
150 views

Bop (Balance of Plant)

The document discusses the balance of plant (BOP) systems that support power plant operations. It describes 14 key BOP systems including: 1) water intake and treatment systems, 2) firefighting systems, 3) condenser systems, 4) cooling water systems, 5) circulating water pipes, and 6) fuel oil systems. For each system it outlines the main components and functions such as pumps, pipes, tanks, and treatment equipment used to intake, treat, circulate, and distribute water and fuel throughout the plant.

Uploaded by

hendiaviano
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
150 views

Bop (Balance of Plant)

The document discusses the balance of plant (BOP) systems that support power plant operations. It describes 14 key BOP systems including: 1) water intake and treatment systems, 2) firefighting systems, 3) condenser systems, 4) cooling water systems, 5) circulating water pipes, and 6) fuel oil systems. For each system it outlines the main components and functions such as pumps, pipes, tanks, and treatment equipment used to intake, treat, circulate, and distribute water and fuel throughout the plant.

Uploaded by

hendiaviano
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 4

BOP (BALANCE OF PLANT)

Suatu system penunjang dalam pengoperasian suatu Plant

System yang ada didalamnya antara lain :

1. Water Intake System


2. Chlorination System
3. Desalination Plant System
4. Water Treatment Plant (WTP)
5. Demineralisation Plant
6. Waster Water Treatment Plant
7. Fire Fighting System
8. Cooling Water System (Cooling Tower)
9. Circulating Water Pump & Pipe (CWP)
10.Fuel Oil System
11. HVAC, CO2, Fire Alarm System
12.Circulating Water Pipe
13.Circulating Water Pump

Kita Bahas satu persatu :


1. Water Treatment Plant System adalah System pengolahan air Air yang dimaksud bisa untuk air
service, Air untuk Cooling System, Air Demin untuk Kebutuhan Boiler & Untuk Pemadam Kebakaran.
Didalam system ini terdiri dari : Raw Water Intake (RWI), Raw Water Treatment Plant (RWTP), Reverse
Osmosis Plant (ROP), Demin Plant, Desalination Plant.
Di system ini equipmentnya antara lain :
- Pump (Water Intake Pump, Demin Pump, ROP Pump dll.)
- Piping System
- Filter (SWRO & BWRO) System
- Water Storage Tank (Demin Tank, Desalination Tank, Ultrafiltration Tank, dll)
 RIVER WATER INTAKE (RWI)

 RAW WATER TREATMENT PLANT (RWTP)


 Untuk pekerjaan di RWTP yang antara lain :
 Sodium Hypochlorite Dosing Tank
 Sodium Hypochlorite Drum Pump
 Sodium Hypochlorite Control Cupboard
 Sodium Hypochlorite Dosing Pump
 Sodium Hypochlorite Piping Work Installation
 Coagulant Aid Dosing Tank
 Coagulant Aid Control Cupboard
 Coagulant Aid Dosing Pump
 Coagulant Aid Dosing Piping Work Installation
 Floculant Dosing Tank
 Floculant Dosing Pump
 Floculant Dosing Control Cupboard
 Floculant Dosing Piping Work Installation
 Lime Dosing Tank
 Lime Dosing Pump
 Lime Dosing Control Cupboard
 Lime Dosing Piping Work Installation
 Sludge Pump

 ROP & DEMINERALIZE WATER TANK


 Reverse Osmosis Plant SWRO Module .
 Reverse Osmosis Plant BWRO Module
 Reverse Osmosis Plant Dual Media Filter
 Reverse Osmosis Plant Activated Carbon Filter
 Reverse Osmosis Plant High Pressure Pump.
 Reverse Osmosis Plant Flushing Tank
 Reverse Osmosis Plant Cleaning Tank
 Reverse Osmosis Plant BufferTank
 DP Cation Exchanger
 DP Anion Exchanger
 DP Mixed Bed Exchanger
 Hydrochloric Acid Storage Tank
 Caustic Soda Storage Tank
 Hydrochloric Acid & Caustic Soda Metering Equipment
 ROP Feed Pump.
 Demin Water Pump
 Dual Media Filter Facepipe
 Activity Carbon Filter Facepipe
 Cation/Anion/Mixed Bed Facepipe
 BWRO Pump.
 SWRO HP Pump with Motor
 DP. Pump.
 Cleaning Pump.
 Flushing Pump

2. Fire Fighting System


System Pemadam Kebakaran
Didalam system ini terdiri dari :

 Main Line Piping


 Pump
 Vessel
 Sprinkler
 Hydrant
3. Condenser System

Berfungsi untuk mengkondensasikan Uap Panas hasil dari Turbine menjadi Air yang selanjutnya dialirkan lagi
ke Boiler.
System yang ada didalamnya dalah : Vacuum Pump, Condenser Extraction Pump, Condenser.

4. Cooling Water System


Berfungsi untuk mendinginkan Air hasil dari Condensasi di Cooling Tower
 Piping System

 Pump System

 Fan & Motor System

 Dosing System
 Drainage System
 Drift Eliminator

5. Circulating Water Pipe


Berfungsi mendistribusikan air dari Water Intake ke Condenser (Inlet Pipe & Outlet Pipe)
Di System ini equipmentnya ada : CW Pump, Piping, Filter dll.
CWP ada 3 macam bahan pembuatannya : Steel plus Rubber Lining, FRP/GRP, Bona Pipe (Steel with
Concrete).

6. Fuel Oil System


Berfungsi untuk mendistribusikan Minyak untuk bahan bakar di Boiler.
Equipmentnya antara lain :
 LFO Pump & LFO HP Pump
 LFO Forwarding Pump (A)
 LFO Forwarding Pump (B)
 LFO Transfer Pump (A)
 LFO Transfer Pump (B)
 LFO Unloading Pump
 LFO HP Pump (diarea Boiler)