PR1012365 - Juniper Networks PR Search

This document describes an issue with interface hold-time down behavior on certain MX Series router cards in Junos OS. It does not support sub-second hold-time down configurations. A hidden configuration statement is introduced to ignore tuning state and allow sub-second hold-down times. However, this does not work for two specific cards, so hold-times over 3 seconds are recommended for those. The problem is marked as a major issue and remains open.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
139 views

PR1012365 - Juniper Networks PR Search

This document describes an issue with interface hold-time down behavior on certain MX Series router cards in Junos OS. It does not support sub-second hold-time down configurations. A hidden configuration statement is introduced to ignore tuning state and allow sub-second hold-down times. However, this does not work for two specific cards, so hold-times over 3 seconds are recommended for those. The problem is marked as a major issue and remains open.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Products & Services Support Training How to Buy

Downloads  Cases  Contracts & Licenses  Documentation & Tools  Account Assistance  MyJuniper

Welcome DAT NGO | My Subscriptions | Logout PR Search Feedback | Help


ARTICLE FEEDBACK
Quality of PR content
PR Search Subscribe Good
OK
Bad
Problem Report
How can we improve this PR content?

Number PR1012365

Title Improve interface hold-time down behavior on MPC3E, MPC4E, MPC5E, MPC6E cards

Release Note On MX Series routers with MPC3E, MPC4E, MPC5E, and MPC6E, Junos OS does not
support short (sub-second) interface hold-time down configuration. A hidden
configuration statement is introduced to ignore DFE tuning state during the
hold-down timer period. This configuration statement allows sub-second hold-
down timer on MPC3E, MPC4E, MPC5E, and MPC6E: set interfaces <intf name> hold- Your response will be used to improve
time up <U ms> down <D ms> alternative our document content.
Submit
The configuration statement does not work on or support 'MPC5E 3D Q 2CGE+4XGE'
and 'MIC6 2X100GE CFP2 OTN', and therefore we recommend configuring hold-time
down of more than 3 seconds for these two cards.

Severity Major

Status Open

Last Modified 2018-03-20 21:35:08 EDT

Resolved In
Release junos
15.1X49-D40 x
15.1R3 x
15.1F6 x
16.1R1 x

Product MX-series

Functional Area software

Triggers This issue might be seen if the following conditions are met:
** Sub-second hold down timer is configured on ethernet interfaces.
** MPC3E, MPC4E, MPC5E, MPC6E are used.