Water Solutions

Hydrocell® Induced Gas


Flotation Separators
Innovative, Energy-Efficient Oil/Solids Separation The Hydrocell® separator has been engineered to provide
the most efficient means of removing oil and suspended
Hydrocell® separators are used in many applications, both
solids from water in large volumes. Combining 95 percent
on- and off-shore, including:
efficiency with high throughput, these units can process
processing oil field produced water solids and oils from 50 ppm to several hundred ppm, with
processing plant wastewater effluents prior to biological product effluents containing less than 5 ppm.
treatment or discharge to public waterways The choice for a wide range of industries, our induced air
tank and drum reconditioning plant applications flotation (IAF), or induced gas floatation (IGF) separators are
innovative, adaptable and affordable.
ballast/bilge water processing
The Hydrocell® separator is ideal for use where oil/water
latex emulsions
separation is required in large volumes, or where other
pulp and paper white water organic matter must be removed from water or industrial
de-inking wastewater effluents. For the removal of volatile organic compounds
(VOCs) from wastewater streams, we also offer gas-tight
vegetable oil and tail oil processing and pressurized designs.
food plant wastes As complete, self-contained units, these separators
coke processing occupy minimum space and can be easily installed for
fixed or portable operation.

siemens.com/energy/water-solutions
Design Capacity Engineering Dimensions Weight
Model GPM (LPM) B/D Length Ft.-in. Width Height Dry Operating
(m) Ft.-in. (m) Ft.-in. (m) lbs. (kg) lbs. (kg)
H-3 1/2D 102 (386) 3,500 12‘-10“ (3.9) 7‘-0“ (2.1) 5‘-6“ (1.7) 4,100 (1,860) 8200 (3,719)
H-5D 146 (553) 5,000 16‘-0“ (4.9) 7‘-0“ (2.1) 4‘-7“ (1.4) 5,700 (2,585) 11300 ( 5,126)
H-7 1/2D 219 (829) 7,500 16‘-2“ (4.9) 7‘-0“ (2.1) 5‘-8“ (1.7) 6,500 (2,948) 15500 (7,031)
H-10D 292 (1,105) 10,000 18‘-4“ (5.6) 8‘-0“ (2.4) 7‘-0“ (2.1) 8,500 (3,856) 19000 (8,618)
H-15D 438 (1,658) 15,000 18‘-4“ (5.6) 8‘-0“ (2.4) 7‘-0“ (2.1) 10,000 (4,536) 26100 (11,839)
H-20D 538 (2,037) 20,000 22‘-0“ (6.7) 9‘-0“ (2.7) 7‘-0“ (2.1) 13,300 (6,033) 35000 (15,876)
H-30D 875 (3,312) 30,000 27‘-3“ (8.3) 9‘-0“ (2.7) 7‘-0“ (2.2) 16,300 (7,394) 39400 (17,872)
H-35D 1021 (3,865) 35,000 32‘-0“ (9.5) 9‘-5“ (2.9) 8‘-0“ (2.4) 17,300 (7,847) 41600 (18,869)
H-40D 1167 (4,418) 40,000 32‘-0“ (9.5) 10‘-3“ (3.2) 7‘-0“ (2.1) 21,300 (9,662) 66800 (30,300)
H-50D 1458 (5,519) 50,000 32‘-0“ (9.5) 10‘-4“ (3.2) 8‘-0“ (2.4) 23,350 (10,591) 80000 (36,287)
H-70D 2042 (7,730) 70,000 37‘-6“ (11.4) 11‘-0“ (3.4) 8‘-0“ (2.4) 27,300 (12,383) 97200 (44,089)
H-1000D 2917 (11,042) 100,000 42‘-0“ (12.8) 11‘-6“ (3.5) 9‘-1“ (2.8) 37,100 (16,828) 130000 (58,967)

Flotation Separation Technology Expert Planning


Induced air (gas) flotation separators operate by inducing To help you plan the best system for your application,
air bubbles into a chemically treated water stream. The Siemens provides an experienced team of application and
chemicals cause the contaminants to attach themselves engineering specialists, trained to help you design, build
to the air bubbles, which then rise to the surface and are and install your system to be operational as soon as possible.
skimmed off. And to keep you up and running, the same team is available
for field support, should the need arise.
Induced air flotation technology offers exceptional efficiency
because the contaminants have eight to 12 opportunities to
come in contact with the bubbles, compared to a single
chance in a dissolved air unit.
Hydrocell® Separator Operation
The Hydrocell® separator operates on a low energy, low
capital cost, hydraulic gas induction principle to process
streams that are characterized by the presence of mostly
free oil, non-dissolved solids, and the absence of any
emulsifying agents such as soaps and caustics.
In the Hydrocell® system design, a single pump is used to
drive four patented air (gas) eductors, rather than having
separate motor-driven impellers for each cell. With no
Siemens AG
moving parts, each eductor efficiently saturates the Freyeslebenstrasse 1
entire volume of each separation cell with fine bubbles. 91058 Erlangen
Germany
Systems Innovation
The Hydrocell® separator uses less power, is substantially Siemens AG
lighter, and has fewer moving parts than standard Energy Sector
Oil & Gas Division
impeller driven systems. It generally costs less, too, which
Wolfgang-Reuter-Platz
adds up to more treatment capacity for less money. 47053 Duisburg
Hydrocell® separator models fit applications up to 100,000 Germany
BPD, and are available in rectangular or pressurized cylindri-
Siemens Energy Inc.
cal designs. The cylindrical design offers a unique backpulse 411 Commercial Parkway
method for skimming, eliminating the need for mechanical Broussard, LA 70518
skimmers and minimizing the number of moving parts. USA
The cylindrical design is also ideal for controlling benzene Phone: +1.337.837.3071
and other gas emissions, as well as for use in pressure E-mail: [email protected]
applications.
Order No. E50001-E450-A132-X-7600 | © 12.2013 Siemens AG