0% found this document useful (0 votes)
222 views

Tank Calculation

This document provides design specifications for a rectangular storage tank, including: 1. Dimensions and material properties of the tank and stiffeners. 2. Calculations for the required spacing, location and size of stiffeners based on the tank's height. 3. Calculations for load, reaction, moment of inertia, pressure, and required plate thickness at different heights along the tank. The used plate thickness of 6 mm meets or exceeds the requirements.

Uploaded by

Sudjono Bro
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
222 views

Tank Calculation

This document provides design specifications for a rectangular storage tank, including: 1. Dimensions and material properties of the tank and stiffeners. 2. Calculations for the required spacing, location and size of stiffeners based on the tank's height. 3. Calculations for load, reaction, moment of inertia, pressure, and required plate thickness at different heights along the tank. The used plate thickness of 6 mm meets or exceeds the requirements.

Uploaded by

Sudjono Bro
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

DOC. NO.

: DK98-048-010
PROGRAM NAME : S-TANK REV. NO. :
VERSION : 1.0 PAGE : /

RECTANGULAR TANKS
( Ref. per book ; PRESSURE VESSEL HANDBOOK )

** DESIGN DATA **
MATERIAL OF TANK, SA240-304L
MATERIAL OF STIFFENING, SA36
NUMBER OF STIFFENINGS, N = 3 EA.
MODULUS OF ELASTICITY AT STIFFENING, E = 30000000 psi
SPECIFIC GRAVITY OF LIQUID, G = 1
HIGHT OF TANK, H = 118.11 in
LENGTH OF TANK, L = 185.04 in
STRESS VALUE OF PLATE, S = 16356 psi
CORROSION ALLOWABLE, CA = 0 in

R1
H1 h1 h1/2
(h1+h2)/2,R2
H H2 h2
h3 (h2+h3)/2, R3
H3

(FIG. 1)

H (in) 60 ~ 84 84 ~ 120 120 ~ 156 > 156


STIFF. NUMBER(EA) 1 2 3 4

(TABLE 1)

NO. / H H1 H2 H3 H4 H5
1 0.60H 0.4H
2 0.45H 0.3H 0.25H
3 0.37H 0.25H 0.21H 0.17H
4 0.31H 0.21H 0.18H 0.16H 0.14H

(TABLE 2)
1. SPACING OF STIFFENINGS ; H [ in ]

NO. / H H1 H2 H3 H4 H5
1 - -
2 - - -
3 43.701 29.528 24.803 20.079
4 - - - - -

2. LOCATION OF STIFFENINGS AT BASE ; h [ in ]

NO. / h h1 h2 h3 h4 h5
1 - -
2 - - -
3 43.7007 73.2282 98.0313 118.11
4 - - - - -
DOC. NO. : DK98-048-010
PROGRAM NAME : S-TANK REV. NO. :
VERSION : 01 PAGE : /

3. LOAD ω = 0.036·G·h^2 / 2 [ lb/in ]

NO. / ω ω1 ω2 ω3 ω4 ω5
1 - -
2 - - -
3 34.376 96.523 172.982 -
4 - - - - -

4. RECTION WITH SUBSCRIPTS INDICATING THE LOCATION, R = 0.7·ω (lb/in)

NO. / R R1 R2 R3 R4 R5
1 - -
2 - - -
3 24.063 67.566 121.088 -
4 - - - - -

5-1. REQUIRED MOMENT OF INERTIA, Ir = 1.25·R·(L^3/E) [ in^4 ]

L^3 / E = 185.04^3 / 30,000,000.00 = 0.2112

NO. / Ir Ir1 Ir2 Ir3 Ir4 Ir5


1 - -
2 - - -
3 6.352 17.837 31.966 -
4 - - - - -

5-2. USED MOMENT OF INERTIA,; I [ in^4 ]


** STIFFENING SIZE 1) ㄱ175 x 175 x 15
2) ㄱ175 x 175 x 15
3) ㄱ175 x 175 x 15
4)
NO. / I I1 I2 I3 I4 I5
1 - - ( - )
2 - - - ( - )
3 34.596 34.596 34.596 - (O.K !!)
4 - - - - - ( - )

6. PRESSURE OF LIQUID, p = 0.036·G·((hn-1 + hn)/2) [ psi ]

NO. / p p1 p2 p3 p4 p5
1 - -
2 - - -
3 0.787 2.105 3.083 3.891
4 - - - - -

7-1. FACTOR DEPENDING ON RATIO OF LENGTH AND HEIGHT OF TANK, H/L,

NO. / H/L H1/L H2/L H3/L H4/L H5/L


1 - -
2 - - -
3 0.236 0.160 0.134 0.109
4 - - - - -
DOC. NO. : DK98-048-010
PROGRAM NAME : S-TANK REV. NO. :
VERSION : 01 PAGE : /

7-2. FACTOR DEPENDING ON RATIO OF LENGTH AND HEIGHT OF TANK, H/L (α ; SEE TABLE)

NO. / α α1 α2 α3 α4 α5
1 - -
2 - - -
3 0.001 0.001 0.001 0.001
4 - - - - -

8-1. REQUIRED PLATE THICKNESS, t = 2.45·L·(αn·(Pn/S))^0.5 + CA [ mm ]

NO. / t t1 t2 t3 t4 t5
1 - -
2 - - -
3 2.525 4.131 4.999 5.616
4 - - - - -

8-2. USED PLATE THICKNESS, T [ mm ]

NO. / T T1 T2 T3 T4 T5
1 - - ( - )
2 - - - ( - )
3 6.000 6.000 6.000 6.000 (O.K !!)
4 - - - - - ( - )