07 Control Systems Time Response Analysis
07 Control Systems Time Response Analysis
We can analyze the response of the control systems in both the time domain and the frequency domain. We
will discuss frequency response analysis of control systems in later chapters. Let us now discuss about the
time response analysis of control systems.
Transient response
Steady state response
The response of control system in time domain is shown in the following figure.
Here, both the transient and the steady states are indicated in the figure. The responses corresponding to
these states are known as transient and steady state responses.
Where,
Transient Response
After applying input to the control system, output takes certain time to reach steady state. So, the output will
be in transient state till it goes to a steady state. Therefore, the response of the control system during the
transient state is known as transient response.
The transient response will be zero for large values of ‘t’. Ideally, this value of ‘t’ is infinity and practically, it is
five times constant.
The part of the time response that remains even after the transient response has zero value for large values of
‘t’ is known as steady state response. This means, the transient response will be zero even during the
steady state.
Example
Let us find the transient and steady state terms of the time response of the control system c(t) = 10 + 5e −t
Here, the second term 5e will be zero as t denotes infinity. So, this is the transient term. And the first
−t
term 10 remains even as t approaches infinity. So, this is the steady state term.
δ(t) = 0 for t ≠ 0
+
and ∫
0
− δ(t)dt = 1
0
So, the unit impulse signal exists only at ‘t’ is equal to zero. The area of this signal under small interval of time
around ‘t’ is equal to zero is one. The value of unit impulse signal is zero for all other values of ‘t’.
u(t) = 1; t ≥ 0
= 0; t < 0
So, the unit step signal exists for all positive values of ‘t’ including zero. And its value is one during this
interval. The value of the unit step signal is zero for all negative values of ‘t’.
r(t) = t; t ≥ 0
= 0; t < 0
We can write unit ramp signal, r(t) in terms of unit step signal, u(t) as
r(t) = tu(t)
= 0; t < 0
We can write unit parabolic signal, p(t) in terms of the unit step signal, u(t) as,
2
t
p(t) = u(t)
2
So, the unit parabolic signal exists for all the positive values of ‘t’ including zero. And its value increases non-
linearly with respect to ‘t’ during this interval. The value of the unit parabolic signal is zero for all the negative
values of ‘t’.