Two-Phase Gas/Liquid Pipe Flow
Ron Darby PhD, PE
Professor Emeritus, Chemical Engineering
Texas A&M University
Types of Two-Phase Flow
»Solid-Gas
»Solid-Liquid
»Gas-Liquid
»Liquid-Liquid
Gas-Liquid Flow Regimes
Homogeneous
Highly Mixed
“Pseudo Single-Phase”
High Reynolds Number
Dispersed –Many Possibilities
Horizontal Pipe Flow
Vertical Pipe Flow
Horizontal Dispersed Flow Regimes
Vertical Pipe Flow Regimes
Horizontal Pipe Flow Regime Map
1/ 2
G L
A W
1/ 2
W 2
L
W
L W L
Vertical Pipe Flow Regime Map
DEFINITIONS
Mass Flow Rate m , Volume Flow Rate (Q)
m m L mG LQL G QG
Mass Flux (G):
m m L mG
G GL GG
A A A
Volume Flux (J):
G GL GG
J J L JG
m L G
QL QG
Vm
A
Volume Fraction Gas: ε
Vol. Fraction Liquid: 1-ε
Phase Velocity:
JL JG
VL , VG
1
Slip Ratio (S): Mass Fraction Gas (Quality x):
VG mG
S x
VL mG m L
Mass Flow Ratio Gas/Liquid:
mG x G
S
mL 1 - x L 1 -
Density of Two-Phase Mixture:
m G 1 L
where
x
ε
x S 1 x ρG / ρL
is the volume fraction of gas in the mixture
Holdup (Volume Fraction Liquid):
S 1 x ρG / ρL
φ 1 ε
x S 1 x ρG / ρL
Slip (S)
Occurs because the gas expands
and speeds up relative to the liquid.
It depends upon fluid properties and
flow conditions.
There are many “models” for slip
(or holdup) in the literature.
Hughmark (1962) slip correlation
Either horizontal or vertical flow:
1 K 1 x / x ρG / ρL
S
K 1 x / x ρG / ρL
where
K 1 0.12 / Z
19
0.95
/ 1 ε
1/ 4
ZN 1/ 6
Re N 1/ 8
Fr
HOMOGENEOUS GAS-LIQUID PIPE
FLOW
Energy Balance (Eng’q Bernoulli Eqn)
2
2 f mG dx dz
G νGL
2
ρm g
dP ρm D dL dL
dL 2 dνG
1 xG
dP
where
ν GL ν G ν L 1 / ρG 1 / ρ L
For “frozen” flow (no phase change):
dx
0
dL
If xG 2 dνG 1 flow is choked.
dP
For ideal gas:
νG νG
1/ k
1 P
P ρP 1
, 1 k / k
T P s ρ1 kP
For frozen ideal gas/liquid choked flow:
ρm kP
G cρm
ε
For flashing flow (Clausius-Clapeyron eqn):
νG ν cT 2
P λ
GL p
T
2
GL
Homogeneous Horizontal Flow
2 fm
2
G dL νGLdx ρm dz
ρm D
dP
1 xG dνG / dP
2
Flashing Flow - Determine x from (adiabatic)
energy balance (or thermo properties database):
c p To Ts
x
λGL
Finite Difference Solution – solve for L
D
ΔL -
4 fm
ΔP G 2
Δν gΔZ / ν 2
νG 2
ΣK fit
Dimensionless
4 f m ΔL 2
ΣK fit - Δη G Δε gΔZ / Po νo ε *2
*2
D εG
where
Δη ΔP / Po
G* G / Po ρo G νo / Po
ε ν / νo ρo / ρ
L= ΔL i
i
the pipe inclination angle
Using Z Lcos , where θ is
with the vertical
for horizontal cos = 0
for vertical up flow cos = 1
for vertical down flow cos = -1
4 f m ΔL
2 Δη G *2
Δε / εG *2
ΣK
fit
-
D 1 gD cos θ / 4 fPo νo ε
Procedure: Find G, Given L, Po and Pe
Select desired ΔP and determine at each
pressure step from Po to Pe
Assume a value for G*
Calculate ΔL at each pressure step.
At choke point, ΔL 0
Adjust until ΣΔL L
Ex: Flashing Water in Pipe
Given: G , Po ,To , xo , so .ρGo , ρLo
Calculate: Pressure Drop over L
1. Assume a value for dL ΔL;
2. Est. f m fn DG / μm (Moody, Churchill, ~0.005)
3.
ΔP1 G 2 2 f m ΔL / ρm D ρm fn ρL , ρG , x , S
,
1 1
4. P1 Po ΔP1 x1 ,Ts1 , ρG 1 , ρL1 s Δx1 ,νGL
1
ρG1 ρL1
5. ΔP2 P2 P1 ΔP2
Choked if ΔP
Separated Pipe Flows
Each Phase Occupies a Specific Fraction of
the Flow Area
“Two-Phase Multiplier” for friction loss:
P 2 P
L ΦR L
fm fR
Reference Single-Phase Flow:
R = L Total flow is liquid: GL mm / A G
R = G Total flow is gas: GG mm / A G
R = LGmTotal flow is liquid in mixture:
GLm 1 x G
R = GGm Total flow is gas in the mixture
GGm xG
Lockhart-Martinelli (1949)
P 2 P
L ΦLm L
f fLm
or:
P 2 P
L ΦGm L
f fGm
L-M Two-Phase Multipliers
C 1
Φ 2
Lm 1 2
χ χ
Φ 2
Gm 1 Cχ χ 2
State Liquid Gas C
tt turbulent turbulent 20
vt laminar turbulent 12
tv turbulent laminar 10
vv laminar laminar 5
L-M Correlating Parameter
P P
χ
2
L f Lm L fGm
2 f Lm 1 x G
2
P
2
L fLm ρL D
P
2 2
2 fGm x G
L fGm ρG D
Friction Factors
f Lm is based on “liquid only” Reynolds No.
1 x GD
N ReLm
μL
f Gm is based on “gas-only” Reynolds No.
xGD
N ReGm =
mG
Duckler et al. (1964)
ρL
Φ 2
Lm α φ β φ
ρ
and
ρG
Φ 2
Gm α φ β φ
ρ
where
φ 1 ε , ρ are “no slip” values
and
lnφ
α φ 1
1.281 0.478 lnφ 0.444 lnφ
2
0.094 lnφ 0.00843 lnφ
3 4
ρG 1 φ
2
ρL φ 2
β φ
ρ φm ρ 1 φm
The Reynolds Number is based on mixture
properties:
DG
N Rem β φ
μm
Sizing Relief Valves
for Two-Phase Flow
m
A
Gvalve
Gvalve K d Gidea l nozzzle
Assume Homogeneous Gas-Liquid
Mixture in an Isentropic Nozzle
1/ 2
Pn
dP
G K d ρn 2
P ρ
o
Discharge Coefficient ( K d )
Values given by manufacturer, or in the “Red Book”
If flow is choked (critical) use :
K d ,gas
If flow is not choked (sub-critical) use :
K d ,liquid
TWO-PHASE DENSITY
ρ ερG 1 ε ρL
Where ε is the volume fraction of gas:
x
ε
x S 1 x ρG / ρL
x = mass fraction of gas phase (quality).
S = slip ratio = vG / vL = (fn(x, ρL/ ρG, …etc)
Flashing Flow
Non-Equilibrium If L 10 cm
Flashing is not complete if L 10 cm
In this case, use
L
x xo xe xo
10
L = nozzle length (cm)
xo = initial quality entering nozzle
x e = local quality assuming equilibrium
If xo > 0.05, x = xe
Determine Quality, xe fn( P )
• The quality is determined as a function
of pressure by an energy balance on
the fluid along the flow path.
• The path is usually assumed to be
isentropic.
HDI – Homogeneous Direct Integration
Exact Solution – Based on Numerical Finite
Difference Equivalent of Nozzle Equation
1/ 2 1/ 2
Pn
dP j n-1 Pj 1 - Pj
Gn ρn K d -2
P ρ
ρn K d -4
o j o ρj1 ρj
Required Information:
ρ vs P at constant s from Po to Pn in increments of
Pj to Pj+1 .
Can be generated from an EOS or from a
database (e.g. steam tables).
(If choked, Gn Gmax at Pn=Pc)
Experimental Data
TABLE I
VALVE SPECIFICATIONS
(Lenzing, et al, 1997, 1998)
Valve KdG KdL Orifice Dia. Orifice Area
(mm)
B&R DN25/40 0.86 0.66 20 0.4869
(Bopp &
Reuther Si63)
ARI DN25/40 0.81 0.59 22.5 0.6163
(Albert Richter
901/902)
1 x 2 “E” 0.962 0.729 13.5 0.2219
(Crosby
JLT/JBS)
Leser DN25/40 0.77 0.51 23 0.6440
(441)
TABLE II
FLOW CONDITIONS
(Lenzing, et al, 1997, 1998)
Fluid Nom. Pressure Po Pb
(bar) (psia) (psia)
Air/Water 5 72.495 14.644
Air/Water 8 115.993 14.644
Air/Water 10 144.991 14.644
Steam/Water 5.4 78.295 14.644
Steam/Water 6.8 98.594 14.644
Steam/Water 8 115.993 14.644
Steam/Water 10.6 153.690 14.644
Air-Water (Frozen) Flow
Four Different Valves
Three Different Pressures
ARI DN25/40, Air/Water Calc 5 bar
Data 5 bar
25000
Calc 8 bar
20000 Data 8 bar
K dG (kg/s m2)
15000
10000
5000
0
0.0001 0.001 0.01 0.1 1
xo
Calc 5 bar
LESER DN25/40, Air/Water
Data 5 bar
25000 Calc 8 bar
Data 8 bar
20000 Calc 10 bar
K dG (kg/s m 2)
Data 10 bar
15000
10000
5000
0
0.0001 0.001 0.01 0.1 1
xo
Calc 5 bar
B&R DN25/40, Air/Water
Data 5 bar
Calc 8 bar
35000
Data 8 bar
30000 Calc 10 bar
Data 10 bar
25000
K dG (kg/s m2)
20000
15000
10000
5000
0
0.0001 0.001 0.01 0.1 1
xo
Crosby 1x2 E, Air/Water Calc 5 bar
Data 5 bar
25000
20000
K dG (kg/s m 2)
15000
10000
5000
0
0.0001 0.001 0.01 0.1 1
xo
HNDI – Homogeneous Non-Equilibrium
Direct Integration
For flashing flows, equilibrium is not reached
until flow path length reaches 10 cm or more.
For L<10 cm, quality (x = gas mass
fraction) is lower than it would be at
equilibrium (xe).
For L < 10 cm, quality is estimated from
x = xo + xe - xo L / 10
where xo is the initial (L = 0) quality (L in cm)
If xo > 0.05, x = xe
Steam-Water Flashing
(non-Equilibrium) Flow
One Valve - Leser 25/40
Four Different Pressures
Leser DN25/40 Valve, Steam/Water, 5.4 bar
5000
Data
4500 HDI
4000 HNDI L=40mm
KdG(kg/sm2)
3500
3000
2500
2000
1500
1000
500
0
0.001 0.01 0.1 1
xo
Leser Valve DN25/40, Steam/Water, 6.8 bar
7000
Data
6000 HDI
HNDI L=40mm
KdG(kg/sm2)
5000
4000
3000
2000
1000
0
0.001 0.01 0.1 1
xo
Leser Valve DN25/40, Steam/Water, 8 bar
8000
Data
7000 HDI
HNDI L=40mm
6000
KdG (kg/sm2)
5000
4000
3000
2000
1000
0
0.001 0.01 0.1 1
xo
Leser Valve DN25/40, Steam/Water, 10.6 bar
9000
Data
8000 HDI
7000 HNDI L=40mm
K dG (kg/sm 2)
6000
5000
4000
3000
2000
1000
0
0.001 0.01 0.1 1
xo
SUMMARY/MORAL
Two-Phase Flow is much more complex
than single –phase flow, because of the
wide variety of possible flow regimes,
phase distributions, thermo/mechanical
equilibrium/non-equilibrium, etc.
Correlations are complex and limited in
scope.
Analysis requires good understanding of
flow mechanism.
References
Baker, O., “Simultaneous Flow of Oil and Gas”, Oil & Gas J.,
53:185-195, 1954
Darby, R., “Fluid Mechanics for Chemical Engineers”, 2nd Ed.,
Ch. 15, Marcel Dekker, 2001
Darby, R., F.E. Self and V.H. Edwards, “Properly Size Pressure
Relief Valves for Two-Phase Gas/Liquid Flow”, Chemical
Engineering, 109, no. 6, pp 68-74, June, (2002)
Darby, R., “On Two-Phase Frozen and Flashing Flows in Safety
Relief Valves”, Journal of Loss Prevention in the Process
Industries, v. 17, pp 255-259, (2004)
Refs (cont’d)
Darby,R, F.E. Self and V.H. Edwards, “Methodology for Sizing Relief Valves
for Two-Phase Gas/Liquid Flow”, Proceedings of the Process Plant
Safety Symposium, 2001, AIChE National Meeting, Houston, TX, April
2001
Duckler, A.E, M. Wicks III and R.G. Cleveland, “Frictional Pressure Drop
in Two-Phase Flow: A Comparison of Existing Correlations for Pressure
Loss and Holdup, AIChE J., 10:38-43, 1964
Govier, G.W. and K. Aziz, “The Flow of Complex Mixtures in Pipes”, Van
Nostrand Reinhold Co., 1972
Hughmark, G.A., “Holdup in Gas-Liquid Flow”, CEP, 58(4), 62-65, l962
Lockhart, R.W., and R.C. Martinelli, “Proposed Correlation of Data for
Isothermal Two-Phase, Two-Component Flow in Pipes”, CEP, 45(1), 39-
48, 1949
Questions??