Motor Wiring Diagram: D.C. Motor Connections

This document provides wiring diagrams and explanations for connecting DC motors. It explains that motors can have either a single or dual voltage shunt field, and diagrams are provided for both. It also details how to connect the field, thermal sensors, stabilizing series field if present, and armature to achieve either clockwise or counterclockwise rotation. Proper connection of the armature, not the field, determines the direction of motor rotation.

Uploaded by

czds6594
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views1 page

Motor Wiring Diagram: D.C. Motor Connections

This document provides wiring diagrams and explanations for connecting DC motors. It explains that motors can have either a single or dual voltage shunt field, and diagrams are provided for both. It also details how to connect the field, thermal sensors, stabilizing series field if present, and armature to achieve either clockwise or counterclockwise rotation. Proper connection of the armature, not the field, determines the direction of motor rotation.

Uploaded by

czds6594
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A2286

Motor Wiring Diagram


D.C. Motor Connections

Your motor will be internally connected according to one of the diagrams shown below. These connections are in
accordance with NEMA MG-1 and American Standards Publication 06. 1 - 1956. Use figure 1 if your motor has a single
voltage shunt field. Use figure 2 if your motor has a dual voltage shunt field.
Figure 1 Figure 2
Single Voltage Shunt Field Dual Voltage Shunt Field
1/2 Shunt Field 1/2 Shunt Field
Space Heater Shunt Field Space Heater

Arm Interpoles Series Field Arm Interpoles Series Field

H1 H2 F1 A1 P1 P2 A2 S1 S2 F2 H1 H2 F1 F2 A1 P1 P2 A2 S1 S2 F3 F4

Field Connections
Your motor will be supplied with either a single voltage or a dual Dual Voltage Field Schematic
voltage shunt field. Single voltage shunt fields have only two High Voltage Connection
field leads (F1, F2) while dual voltage shunt fields have four F1 to + Field supply
field leads (F1, F2, F3, F4). F4 to - Field supply
F2 & F3 Joined F1 F3 F2 F4
+
F4 -
Single Voltage Field Schematic
Low Voltage Connection F4
F1
F1 to + Field supply F1 & F3 to + Field supply
F2 to - Field supply F3 F2
F2 & F4 to - field supply
+ F1 F2 - + -

Thermal Sensor Connections


Leads P1 and P2, when supplied, are from a thermal sensor element attached to an interpole coil. This contact is
normally closed, opening on motor overtemperature.

Armature Circuit Connections


Some motors are furnished with a stabilizing series field (S1, S2). Check the drive control diagram to see if the series
field should be connected into the armature circuit. Connect the motor as shown below for clockwise or counterclockwise
rotation.
Rotation Facing Commutator
Clockwise Counterclockwise

Stabilized Shunt Wound (with series field)


A2 to + Armature supply A1 to + Armature supply
A1 & S1 Joined A2 & S1 Joined
S2 to - Armature supply S2 to - Armature supply

Straight Shunt Wound (no series field


A2 to + Armature supply A1 to + Armature supply
A1 to - Armature supply A2 to - Armature supply
When A1 and F1 are the same polarity rotation will be counterclockwise when viewed facing the commutator end to the
motor. To reverse the direction of motor rotation always reverse the armature connections, not the field connections.

Connection Drawing: A2286