ACS800 Democase Default Parameters

This document contains default parameter values for an ACS800 demo case. It lists 51 actual signal values such as speed, current, temperature and status values. It also lists parameters for start/stop/direction signals, reference selection, constant speeds, analog inputs and more. The parameters are organized into numbered sections for easy reference.

Uploaded by

Remigio Mendoza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
372 views

ACS800 Democase Default Parameters

This document contains default parameter values for an ACS800 demo case. It lists 51 actual signal values such as speed, current, temperature and status values. It also lists parameters for start/stop/direction signals, reference selection, constant speeds, analog inputs and more. The parameters are organized into numbered sections for easy reference.

Uploaded by

Remigio Mendoza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

Parameters Page 1 of 14

Parameters and Signals


ACS800 democase default parameters

File:
ACS800_democase_default_parameters
Properties

Control Board Type RMIO


Kind ACS800
Name ACS 800 DEMO
Product Family ACS 800 DEMO
System software version 4.200

Application

Base library FFFFF.002


Name ASARF018
Version 11-06-14 12:34:48:546

Parameters and Signals


01: ACTUAL SIGNALS

Name Value
01.01: PROCESS VARIABLE [%] 0.0
01.02: SPEED [rpm] 0.0
01.03: FREQUENCY [Hz] 0.00
01.04: CURRENT [A] 0.00
01.05: TORQUE [%] 0.00
01.06: POWER [%] 0.00
01.07: DC BUS VOLTAGE V [V] 652.1
01.08: MAINS VOLTAGE [V] 415.0
01.09: OUTPUT VOLTAGE [V] 0.0
01.10: ACS800 TEMP [%] 32.7
01.11: EXTERNAL REF 1 [rpm] 0.0
01.12: EXTERNAL REF 2 [%] 0.0
01.13: CTRL LOCATION LOCAL
01.14: OP HOUR COUNTER [h] 9.57
01.15: KILOWATT HOURS [kWh] 0.0
01.16: APPL BLOCK OUTPUT [%] 0.0
01.17: DI6-1 STATUS 0000000b
01.18: AI1 [V] -3.9
01.19: AI2 [mA] 15.6
01.20: AI3 [mA] 11.2
01.21: RO3-1 STATUS 0000101b
01.22: AO1 [mA] 0.0
01.23: AO2 [mA] 0.0
01.24: ACTUAL VALUE 1 [%] 0.0
01.25: ACTUAL VALUE 2 [%] 0.0

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 2 of 14

01.26: CONTROL DEVIATION [%] 0.0


01.27: APPLICATION MACRO FACTORY
01.28: EXT AO1 [mA] 0.0
01.29: EXT AO2 [mA] 0.0
01.30: PP 1 TEMP [C] 30.9
01.31: PP 2 TEMP [C] 0.0
01.32: PP 3 TEMP [C] 0.0
01.33: PP 4 TEMP [C] 0.0
01.34: ACTUAL VALUE [%] 0.0
01.35: MOTOR 1 TEMP [C] 0.0
01.36: MOTOR 2 TEMP [C] 0.0
01.37: MOTOR TEMP EST [C] 30.0
01.38: AI5 [mA] 0.0
01.39: AI6 [mA] 0.0
01.40: DI7-12 STATUS 0000000b
01.41: EXT RO STATUS 0000001b
01.42: PROCESS SPEED REL [%] 0.0
01.43: MOTOR RUN TIME [h] 0.80
01.44: FAN ON-TIME [h] 2.67
01.45: CTRL BOARD TEMP [C] 40
01.46: SAVED KWH [kWh] 0.1
01.47: SAVED GWH [GWh] 0
01.48: SAVED AMOUNT [EUR] 0.0
01.49: SAVED AMOUNT M [MEU] 0
01.50: SAVED CO2 [kg] 0.0
01.51: SAVED CO2 KTON [kt] 0

02: ACTUAL SIGNALS

Name Value
02.01: SPEED REF 2 [rpm] 0
02.02: SPEED REF 3 [rpm] 0
02.09: TORQUE REF 2 [%] 0.00
02.10: TORQUE REF 3 [%] 0.00
02.13: TORQ USED REF [%] 0.00
02.14: FLUX REF [%] 100
02.17: SPEED ESTIMATED [rpm] 0.0
02.18: SPEED MEASURED [rpm] 0.00
02.19: MOTOR ACCELERATIO [rpm/s] 0.0
02.20: USER CURRENT [%] 0.0

03: ACTUAL SIGNALS

Name Value
03.01: MAIN CTRL WORD 477h
03.02: MAIN STATUS WORD 1033h
03.03: AUX STATUS WORD 1880h
03.04: LIMIT WORD 1 0h
03.05: FAULT WORD 1 0h
03.06: FAULT WORD 2 0h
03.07: SYSTEM FAULT 0h
03.08: ALARM WORD 1 0h
03.09: ALARM WORD 2 0h
03.11: FOLLOWER MCW 0h
03.13: AUX STATUS WORD 3 700h

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 3 of 14

03.14: AUX STATUS WORD 4 0h


03.15: FAULT WORD 4 0h
03.16: ALARM WORD 4 0h
03.17: FAULT WORD 5 0h
03.18: ALARM WORD 5 0h
03.19: INT INIT FAULT 0h
03.20: LATEST FAULT 5300h
03.21: 2.LATEST FAULT 0h
03.22: 3.LATEST FAULT 0h
03.23: 4.LATEST FAULT 0h
03.24: 5.LATEST FAULT 0h
03.25: LATEST WARNING FF69h
03.26: 2.LATEST WARNING FF33h
03.27: 3.LATEST WARNING FF32h
03.28: 4.LATEST WARNING 0h
03.29: 5.LATEST WARNING FF34h
03.30: LIMIT WORD INV 0h
03.31: ALARM WORD 6 0h
03.32: EXT IO STATUS 0h
03.33: FAULT WORD 6 0h

04: ACTUAL SIGNALS

Name Value
04.01: FAULTED INT INFO 0h
04.02: INT SC INFO 0h

09: ACTUAL SIGNALS

Name Value
09.01: AI1 SCALED -7800
09.02: AI2 SCALED 15616
09.03: AI3 SCALED 11193
09.04: AI5 SCALED 0
09.05: AI6 SCALED 0
09.06: DS MCW 0h
09.07: MASTER REF1 0
09.08: MASTER REF2 0
09.09: AUX DS VAL1 0
09.10: AUX DS VAL2 0
09.11: AUX DS VAL3 0
09.12: LCU ACT SIGNAL1 0
09.13: LCU ACT SIGNAL2 0

10: START/STOP/DIR

Name Value
10.01: EXT1 STRT/STP/DIR DI1,2
10.02: EXT2 STRT/STP/DIR NOT SEL
10.03: REF DIRECTION FORWARD
10.04: EXT 1 STRT PTR +.000.000.00
10.05: EXT 2 STRT PTR +.000.000.00
10.06: JOG SPEED SELECT NOT SEL
10.07: NET CONTROL <Read-protected>
10.08: NET REFERENCE <Read-protected>

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 4 of 14

10.09: SLS ACTIVE NO

11: REFERENCE SELECT

Name Value
11.01: KEYPAD REF SEL REF1 (rpm)
11.02: EXT1/EXT2 SELECT EXT1
11.03: EXT REF1 SELECT AI1
11.04: EXT REF1 MINIMUM [rpm] 0
11.05: EXT REF1 MAXIMUM [rpm] 1500
11.06: EXT REF2 SELECT KEYPAD
11.07: EXT REF2 MINIMUM [%] 0
11.08: EXT REF2 MAXIMUM [%] 100
11.09: EXT 1/2 SEL PTR +.000.000.00
11.10: EXT 1 REF PTR +.000.000.00
11.11: EXT 2 REF PTR +.000.000.00

12: CONSTANT SPEEDS

Name Value
12.01: CONST SPEED SEL DI5,6
12.02: CONST SPEED 1 [rpm] 300
12.03: CONST SPEED 2 [rpm] 600
12.04: CONST SPEED 3 [rpm] 900
12.05: CONST SPEED 4 [rpm] 300
12.06: CONST SPEED 5 [rpm] 0
12.07: CONST SPEED 6 [rpm] 0
12.08: CONST SPEED 7 [rpm] 0
12.09: CONST SPEED 8 [rpm] 0
12.10: CONST SPEED 9 [rpm] 0
12.11: CONST SPEED 10 [rpm] 0
12.12: CONST SPEED 11 [rpm] 0
12.13: CONST SPEED 12 [rpm] 0
12.14: CONST SPEED 13 [rpm] 0
12.15: CONST SPEED 14 [rpm] 0
12.16: CONST SPEED 15 [rpm] 0

13: ANALOGUE INPUTS

Name Value
13.01: MINIMUM AI1 0V
13.02: MAXIMUM AI1 10 V
13.03: SCALE AI1 [%] 100.0
13.04: FILTER AI1 [s] 0.10
13.05: INVERT AI1 NO
13.06: MINIMUM AI2 0 mA
13.07: MAXIMUM AI2 20 mA
13.08: SCALE AI2 [%] 100.0
13.09: FILTER AI2 [s] 0.10
13.10: INVERT AI2 NO
13.11: MINIMUM AI3 0 mA
13.12: MAXIMUM AI3 20 mA
13.13: SCALE AI3 [%] 100.0
13.14: FILTER AI3 [s] 0.10
13.15: INVERT AI3 NO

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 5 of 14

13.16: MINIMUM AI5 0 mA


13.17: MAXIMUM AI5 20 mA
13.18: SCALE AI5 [%] 100.0
13.19: FILTER AI5 [s] 0.10
13.20: INVERT AI5 NO
13.21: MINIMUM AI6 0 mA
13.22: MAXIMUM AI6 20 mA
13.23: SCALE AI6 [%] 100.0
13.24: FILTER AI6 [s] 0.10
13.25: INVERT AI6 NO

14: RELAY OUTPUTS

Name Value
14.01: RELAY RO1 OUTPUT READY
14.02: RELAY RO2 OUTPUT RUNNING
14.03: RELAY RO3 OUTPUT FAULT(-1)
14.04: RO1 TON DELAY [s] 0.0
14.05: RO1 TOFF DELAY [s] 0.0
14.06: RO2 TON DELAY [s] 0.0
14.07: RO2 TOFF DELAY [s] 0.0
14.08: RO3 TON DELAY [s] 0.0
14.09: RO3 TOFF DELAY [s] 0.0
14.10: DIO MOD1 RO1 READY
14.11: DIO MOD1 RO2 RUNNING
14.12: DIO MOD2 RO1 FAULT
14.13: DIO MOD2 RO2 WARNING
14.14: DIO MOD3 RO1 REF 2 SEL
14.15: DIO MOD3 RO2 AT SPEED
14.16: RO PTR1 +.000.000.00
14.17: RO PTR2 +.000.000.00
14.18: RO PTR3 +.000.000.00
14.19: RO PTR4 +.000.000.00
14.20: RO PTR5 +.000.000.00
14.21: RO PTR6 +.000.000.00
14.22: RO PTR7 +.000.000.00
14.23: RO PTR8 +.000.000.00
14.24: RO PTR9 +.000.000.00

15: ANALOGUE OUTPUTS

Name Value
15.01: ANALOGUE OUTPUT1 SPEED
15.02: INVERT AO1 NO
15.03: MINIMUM AO1 0 mA
15.04: FILTER AO1 [s] 0.10
15.05: SCALE AO1 [%] 100
15.06: ANALOGUE OUTPUT2 CURRENT
15.07: INVERT AO2 NO
15.08: MINIMUM AO2 0 mA
15.09: FILTER AO2 [s] 2.00
15.10: SCALE AO2 [%] 100
15.11: AO1 PTR +.000.000.00
15.12: AO2 PTR +.000.000.00

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 6 of 14

16: SYST CTRL INPUTS

Name Value
16.01: RUN ENABLE YES
16.02: PARAMETER LOCK OPEN
16.03: PASS CODE 0
16.04: FAULT RESET SEL NOT SEL
16.05: USER MACRO IO CHG NOT SEL
16.06: LOCAL LOCK OFF
16.07: PARAMETER SAVE DONE
16.08: RUN ENA PTR +.000.000.00
16.09: CTRL BOARD SUPPLY INTERNAL 24V
16.10: ASSISTANT SEL ON
16.11: FAULT RESET PTR +.000.000.00
16.12: RESET COUNTER NO

20: LIMITS

Name Value
20.01: MINIMUM SPEED [rpm] -1500
20.02: MAXIMUM SPEED [rpm] 1500
20.03: MAXIMUM CURRENT [A] 2.2
20.04: TORQ MAX LIM1 [%] 300.0
20.05: OVERVOLTAGE CTRL ON
20.06: UNDERVOLTAGE CTRL ON
20.07: MINIMUM FREQ [Hz] <Read-protected>
20.08: MAXIMUM FREQ [Hz] <Read-protected>
20.11: P MOTORING LIM [%] 300.0
20.12: P GENERATING LIM [%] -300.0
20.13: MIN TORQ SEL NEG MAX TORQ
20.14: MAX TORQ SEL MAX LIM1
20.15: TORQ MIN LIM1 [%] 0.0
20.16: TORQ MIN LIM2 [%] 0.0
20.17: TORQ MAX LIM2 [%] 300.0
20.18: TORQ MIN PTR +.000.000.00
20.19: TORQ MAX PTR +.000.000.00
20.20: MIN AI SCALE [%] 0.0
20.21: MAX AI SCALE [%] 300.0
20.22: SLS SPEED LIMIT [rpm] 0

21: START/STOP

Name Value
21.01: START FUNCTION AUTO
21.02: CONST MAGN TIME [ms] 500.0
21.03: STOP FUNCTION COAST
21.04: DC HOLD NO
21.05: DC HOLD SPEED [rpm] 5
21.06: DC HOLD CURR [%] 30.0
21.07: RUN ENABLE FUNC COAST STOP
21.08: SCALAR FLYSTART <Read-protected>
21.09: START INTRL FUNC OFF2 STOP
21.10: ZERO SPEED DELAY [s] 0.50

22: ACCEL/DECEL

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 7 of 14

Name Value
22.01: ACC/DEC SEL DI4
22.02: ACCEL TIME 1 [s] 20.00
22.03: DECEL TIME 1 [s] 20.00
22.04: ACCEL TIME 2 [s] 60.00
22.05: DECEL TIME 2 [s] 60.00
22.06: ACC/DEC RAMP SHPE [s] 0.00
22.07: EM STOP RAMP TIME [s] 3.00
22.08: ACC PTR +.000.000.00
22.09: DEC PTR +.000.000.00
22.10: SLS ACCELER TIME [s] 20.00
22.11: SLS DECELER TIME [s] 20.00

23: SPEED CTRL

Name Value
23.01: GAIN 10.0
23.02: INTEGRATION TIME [s] 2.50
23.03: DERIVATION TIME [ms] 0.0
23.04: ACC COMPENSATION [s] 0.00
23.05: SLIP GAIN [%] 100.0
23.06: AUTOTUNE RUN NO
23.07: SP ACT FILT TIME [ms] 8.0

25: CRITICAL SPEEDS

Name Value
25.01: CRIT SPEED SELECT OFF
25.02: CRIT SPEED 1 LOW [rpm] 0
25.03: CRIT SPEED 1 HIGH [rpm] 0
25.04: CRIT SPEED 2 LOW [rpm] 0
25.05: CRIT SPEED 2 HIGH [rpm] 0
25.06: CRIT SPEED 3 LOW [rpm] 0
25.07: CRIT SPEED 3 HIGH [rpm] 0

26: MOTOR CONTROL

Name Value
26.01: FLUX OPTIMIZATION NO
26.02: FLUX BRAKING YES
26.03: IR-COMPENSATION [%] <Read-protected>
26.04: IR STEP UP FREQ [Hz] <Read-protected>
26.05: HEX FIELD WEAKEN OFF
26.06: FLUX REF PTR C. 10000
26.07: FLYSTART CUR REF [%] 50
26.08: FLYSTART INIT DLY 25
26.09: FS METHOD OFF

27: BRAKE CHOPPER

Name Value
27.01: BRAKE CHOPPER CTL OFF
27.02: BR OVERLOAD FUNC NO
27.03: BR RESISTANCE [Ohm] 100.00

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 8 of 14

27.04: BR THERM T CONST [s] 0.000


27.05: MAX CONT BR POWER [kW] 0.00
27.06: BC CTRL MODE COMMON DC

30: FAULT FUNCTIONS

Name Value
30.01: AI<MIN FUNCTION FAULT
30.02: PANEL LOSS FAULT
30.03: EXTERNAL FAULT NOT SEL
30.04: MOTOR THERM PROT NO
30.05: MOT THERM P MODE DTC
30.06: MOTOR THERM TIME [s] 1258.9
30.07: MOTOR LOAD CURVE [%] 100.0
30.08: ZERO SPEED LOAD [%] 74.0
30.09: BREAK POINT [Hz] 45.0
30.10: STALL FUNCTION FAULT
30.11: STALL FREQ HI [Hz] 20.0
30.12: STALL TIME [s] 20.00
30.13: UNDERLOAD FUNC NO
30.14: UNDERLOAD TIME [s] 600
30.15: UNDERLOAD CURVE 1
30.16: MOTOR PHASE LOSS NO
30.17: EARTH FAULT FAULT
30.18: COMM FLT FUNC FAULT
30.19: MAIN REF DS T-OUT [s] 3.00
30.20: COMM FLT RO/AO ZERO
30.21: AUX DS T-OUT [s] 3.00
30.22: IO CONFIG FUNC WARNING
30.23: LIMIT WARNING 0000000b

31: AUTOMATIC RESET

Name Value
31.01: NUMBER OF TRIALS 0
31.02: TRIAL TIME [s] 30.0
31.03: DELAY TIME [s] 0.0
31.04: OVERCURRENT NO
31.05: OVERVOLTAGE NO
31.06: UNDERVOLTAGE NO
31.07: AI SIGNAL<MIN NO
31.08: LINE CONV NO

32: SUPERVISION

Name Value
32.01: SPEED1 FUNCTION NO
32.02: SPEED1 LIMIT [rpm] 0
32.03: SPEED2 FUNCTION NO
32.04: SPEED2 LIMIT [rpm] 0
32.05: CURRENT FUNCTION NO
32.06: CURRENT LIMIT [A] 0
32.07: TORQUE1 FUNCTION NO
32.08: TORQUE1 LIMIT [%] 0
32.09: TORQUE2 FUNCTION NO

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 9 of 14

32.10: TORQUE2 LIMIT [%] 0


32.11: REF1 FUNCTION NO
32.12: REF1 LIMIT [rpm] 0
32.13: REF2 FUNCTION NO
32.14: REF2 LIMIT [%] 0
32.15: ACT1 FUNCTION NO
32.16: ACT1 LIMIT [%] 0
32.17: ACT2 FUNCTION NO
32.18: ACT2 LIMIT [%] 0

33: INFORMATION

Name Value
33.01: SOFTWARE VERSION AS7R7365
33.02: APPL SW VERSION ASARF018
33.03: TEST DATE 0h
33.04: BOARD TYPE RMIO - 0X

34: PROCESS VARIABLE

Name Value
34.01: SCALE 100.00
34.02: P VAR UNIT %
34.03: SELECT P VAR 142
34.04: MOTOR SP FILT TIM [ms] 500
34.05: TORQ ACT FILT TIM [ms] 100
34.06: RESET RUN TIME NO

35: MOT TEMP MEAS

Name Value
35.01: MOT1 TEMP AI1 SEL NOT IN USE
35.02: MOT 1 TEMP ALM L [C] 110
35.03: MOT 1 TEMP FLT L [C] 130
35.04: MOT2 TEMP AI2 SEL NOT IN USE
35.05: MOT 2 TEMP ALM L [C] 110
35.06: MOT 2 TEMP FLT L [C] 130
35.07: MOT MOD COMPENSAT YES
35.08: MOT MOD COMP PTR +.000.000.00

40: PID CONTROL

Name Value
40.01: PID GAIN 1.0
40.02: PID INTEG TIME [s] 60.00
40.03: PID DERIV TIME [s] 0.00
40.04: PID DERIV FILTER [s] 1.00
40.05: ERROR VALUE INV NO
40.06: ACTUAL VALUE SEL ACT1
40.07: ACTUAL1 INPUT SEL AI2
40.08: ACTUAL2 INPUT SEL AI2
40.09: ACT1 MINIMUM [%] 0
40.10: ACT1 MAXIMUM [%] 100
40.11: ACT2 MINIMUM [%] 0

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 10 of 14

40.12: ACT2 MAXIMUM [%] 100


40.13: PID INTEGRATION ON
40.14: TRIM MODE OFF
40.15: TRIM REF SEL AI1
40.16: TRIM REFERENCE [%] 0.0
40.17: TRIM RANGE ADJUST [%] 100.0
40.18: TRIM SELECTION SPEED TRIM
40.19: ACTUAL FILT TIME [s] 0.04
40.20: SLEEP SELECTION <Read-protected>
40.21: SLEEP LEVEL [rpm] <Read-protected>
40.22: SLEEP DELAY [s] <Read-protected>
40.23: WAKE UP LEVEL [%] <Read-protected>
40.24: WAKE UP DELAY [s] <Read-protected>
40.25: ACTUAL1 PTR +.000.000.00
40.26: PID MINIMUM [%] -100.0
40.27: PID MAXIMUM [%] 100.0
40.28: TRIM REF PTR +.000.000.00

42: BRAKE CONTROL

Name Value
42.01: BRAKE CTRL OFF
42.02: BRAKE ACKNOWLEDGE OFF
42.03: BRAKE OPEN DELAY [s] 0.0
42.04: BRAKE CLOSE DELAY [s] 0.0
42.05: ABS BRAKE CLS SPD [RPM] 10
42.06: BRAKE FAULT FUNC FAULT
42.07: STRT TORQ REF SEL NO
42.08: START TORQ REF [%] 0.0
42.09: EXTEND RUN T [s] 0.0
42.10: LOW REF BRK HOLD [s] 0.0

45: ENERGY OPT

Name Value
45.02: ENERGY TARIFF1 [c/E] 0.000
45.06: E TARIFF UNIT EUR
45.08: PUMP REF POWER [%] 100.00
45.09: ENERGY RESET DONE

52: STANDARD MODBUS

Name Value
52.01: STATION NUMBER 1
52.02: BAUDRATE 9600
52.03: PARITY ODD

60: MASTER/FOLLOWER

Name Value
60.01: MASTER LINK MODE NOT IN USE
60.02: TORQUE SELECTOR <Read-protected>
60.03: WINDOW SEL ON <Read-protected>
60.04: WINDOW WIDTH POS [rpm] <Read-protected>

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 11 of 14

60.05: WINDOW WIDTH NEG [rpm] <Read-protected>


60.06: DROOP RATE [%] 0.0
60.07: MASTER SIGNAL 2 202
60.08: MASTER SIGNAL 3 213

70: DDCS CONTROL

Name Value
70.01: CHANNEL 0 ADDR 1
70.02: CHANNEL 3 ADDR 1
70.03: CH1 BAUD RATE 4 Mbit/s
70.04: CH0 DDCS HW CONN RING
70.05: CH2 DDCS HW CONN RING

72: USER LOAD CURVE

Name Value
72.01: OVERLOAD FUNCTION NO
72.02: LOAD CURRENT1 [%] 500.0
72.03: LOAD CURRENT2 [%] 500.0
72.04: LOAD CURRENT3 [%] 500.0
72.05: LOAD CURRENT4 [%] 500.0
72.06: LOAD CURRENT5 [%] 500.0
72.07: LOAD CURRENT6 [%] 500.0
72.08: LOAD CURRENT7 [%] 500.0
72.09: LOAD CURRENT8 [%] 500.0
72.10: LOAD FREQ1 [%] 0.0
72.11: LOAD FREQ2 [%] 20.0
72.12: LOAD FREQ3 [%] 40.0
72.13: LOAD FREQ4 [%] 60.0
72.14: LOAD FREQ5 [%] 80.0
72.15: LOAD FREQ6 [%] 100.0
72.16: LOAD FREQ7 [%] 130.0
72.17: LOAD FREQ8 [%] 150.0
72.18: LOAD CURRENT LIM [%] 500.0
72.19: LOAD THERMAL TIME [s] 1.0
72.20: LOAD COOLING TIME [s] 1

83: ADAPT PROG CTRL

Name Value
83.01: ADAPT PROG CMD EDIT
83.02: EDIT COMMAND NO
83.03: EDIT BLOCK 0
83.04: TIMELEVEL SEL 100 ms
83.05: PASSCODE 0

84: ADAPTIVE PROGRAM

Name Value
84.01: STATUS 8h
84.02: FAULTED PAR +.000.000.00
84.05: BLOCK1 NO
84.06: INPUT1 +.000.000.00

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 12 of 14

84.07: INPUT2 +.000.000.00


84.08: INPUT3 +.000.000.00
84.09: OUTPUT 0
84.10: BLOCK2 NO
84.11: INPUT1 +.000.000.00
84.12: INPUT2 +.000.000.00
84.13: INPUT3 +.000.000.00
84.14: OUTPUT 0
84.15: BLOCK3 NO
84.16: INPUT1 +.000.000.00
84.17: INPUT2 +.000.000.00
84.18: INPUT3 +.000.000.00
84.19: OUTPUT 0
84.20: BLOCK4 NO
84.21: INPUT1 +.000.000.00
84.22: INPUT2 +.000.000.00
84.23: INPUT3 +.000.000.00
84.24: OUTPUT 0
84.25: BLOCK5 NO
84.26: INPUT1 +.000.000.00
84.27: INPUT2 +.000.000.00
84.28: INPUT3 +.000.000.00
84.29: OUTPUT 0
84.30: BLOCK6 NO
84.31: INPUT1 +.000.000.00
84.32: INPUT2 +.000.000.00
84.33: INPUT3 +.000.000.00
84.34: OUTPUT 0
84.35: BLOCK7 NO
84.36: INPUT1 +.000.000.00
84.37: INPUT2 +.000.000.00
84.38: INPUT3 +.000.000.00
84.39: OUTPUT 0
84.40: BLOCK8 NO
84.41: INPUT1 +.000.000.00
84.42: INPUT2 +.000.000.00
84.43: INPUT3 +.000.000.00
84.44: OUTPUT 0
84.45: BLOCK9 NO
84.46: INPUT1 +.000.000.00
84.47: INPUT2 +.000.000.00
84.48: INPUT3 +.000.000.00
84.49: OUTPUT 0
84.50: BLOCK10 NO
84.51: INPUT1 +.000.000.00
84.52: INPUT2 +.000.000.00
84.53: INPUT3 +.000.000.00
84.54: OUTPUT 0
84.55: BLOCK11 NO
84.56: INPUT1 +.000.000.00
84.57: INPUT2 +.000.000.00
84.58: INPUT3 +.000.000.00
84.59: OUTPUT 0
84.60: BLOCK12 NO
84.61: INPUT1 +.000.000.00
84.62: INPUT2 +.000.000.00

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 13 of 14

+.000.000.00
84.64: OUTPUT 0
84.65: BLOCK13 NO
84.66: INPUT1 +.000.000.00
84.67: INPUT2 +.000.000.00
84.68: INPUT3 +.000.000.00
84.69: OUTPUT 0
84.70: BLOCK14 NO
84.71: INPUT1 +.000.000.00
84.72: INPUT2 +.000.000.00
84.73: INPUT3 +.000.000.00
84.74: OUTPUT 0
84.75: BLOCK15 NO
84.76: INPUT1 +.000.000.00
84.77: INPUT2 +.000.000.00
84.78: INPUT3 +.000.000.00
84.79: OUTPUT 0

85: USER CONSTANTS

Name Value
85.01: CONSTANT1 0
85.02: CONSTANT2 0
85.03: CONSTANT3 0
85.04: CONSTANT4 0
85.05: CONSTANT5 0
85.06: CONSTANT6 0
85.07: CONSTANT7 0
85.08: CONSTANT8 0
85.09: CONSTANT9 0
85.10: CONSTANT10 0
85.11: STRING1 MESSAGE1
85.12: STRING2 MESSAGE2
85.13: STRING3 MESSAGE3
85.14: STRING4 MESSAGE4
85.15: STRING5 MESSAGE5

90: D SET REC ADDR

Name Value
90.01: AUX DS REF3 0
90.02: AUX DS REF4 0
90.03: AUX DS REF5 0
90.04: MAIN DS SOURCE 1
90.05: AUX DS SOURCE 3

92: D SET TR ADDR

Name Value
92.02: MAIN DS ACT1 102
92.03: MAIN DS ACT2 105
92.04: AUX DS ACT3 305
92.05: AUX DS ACT4 308
92.06: AUX DS ACT5 306
92.07: MSW B10 PTR +.003.014.09

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012
Parameters Page 14 of 14

92.08: MSW B13 PTR +.000.000.00


92.09: MSW B14 PTR +.000.000.00

95: HARDWARE SPECIF

Name Value
95.01: FAN SPD CTRL MODE CONTROLLED
95.02: FUSE SWITCH CTRL OFF
95.03: INT CONFIG USER 1
95.04: EX/SIN REQUEST NO
95.05: ENA INC SW FREQ <Read-protected>
95.06: LCU Q PW REF 0
95.07: LCU DC REF 0
95.08: LCU PAR1 SEL 106
95.09: LCU PAR2 SEL 110
95.10: TEMP INV AMBIENT [C] 40.0
95.11: SUPPLY CTRL MODE NONE
95.12: LCU RUN PTR +.000.000.00

98: OPTION MODULES

Name Value
98.01: ENCODER MODULE NO
98.02: COMM. MODULE LINK NO
98.03: DI/O EXT MODULE 1 NO
98.04: DI/O EXT MODULE 2 NO
98.05: DI/O EXT MODULE 3 NO
98.06: AI/O EXT MODULE NO
98.07: COMM PROFILE ABB DRIVES
98.09: DI/O EXT1 DI FUNC DI7,8,9
98.10: DI/O EXT2 DI FUNC DI10,11,12
98.11: DI/O EXT3 DI FUNC DI11,12
98.12: AI/O MOTOR TEMP NO
98.13: AI/O EXT AI1 FUNC UNIPOLAR AI5
98.14: AI/O EXT AI2 FUNC UNIPOLAR AI6
98.16: SIN FILT SUPERV <Read-protected>

99: START-UP DATA

Name Value
99.01: LANGUAGE ENGLISH
99.02: APPLICATION MACRO FACTORY
99.03: APPLIC RESTORE NO
99.04: MOTOR CTRL MODE DTC
99.05: MOTOR NOM VOLTAGE [V] 220
99.06: MOTOR NOM CURRENT [A] 1.3
99.07: MOTOR NOM FREQ [Hz] 50.00
99.08: MOTOR NOM SPEED [rpm] 1380
99.09: MOTOR NOM POWER [kW] 0.2
99.10: MOTOR ID RUN MODE ID MAGN
99.11: DEVICE NAME

file://C:\Users\fitehei\AppData\Local\Temp\Parameters.xml 17.10.2012