0% found this document useful (0 votes)
735 views11 pages

Epa Calculation For Towers

This document contains calculations for designing various structural components to withstand wind forces: 1) It first calculates wind forces on a tubular pole and appurtenances like antennas based on wind speed, height, and structure dimensions. 2) It then checks the strength of the tubular pole by calculating its compressive, flexural, shear, and torsional capacities. 3) Additional calculations determine the compressive strength of tubular leg members for latticed structures and the interaction of axial compression and bending forces. 4) Minimum bracing resistance is also checked for a supported member.

Uploaded by

fadil3m2422
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
735 views11 pages

Epa Calculation For Towers

This document contains calculations for designing various structural components to withstand wind forces: 1) It first calculates wind forces on a tubular pole and appurtenances like antennas based on wind speed, height, and structure dimensions. 2) It then checks the strength of the tubular pole by calculating its compressive, flexural, shear, and torsional capacities. 3) Additional calculations determine the compressive strength of tubular leg members for latticed structures and the interaction of axial compression and bending forces. 4) Minimum bracing resistance is also checked for a supported member.

Uploaded by

fadil3m2422
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Design Wind Force Calculation

Design Wind Speed 160 KPh


Height above Ground Level, z 26 m
Exposure Category C
Velocity Pressure coefficient, Kz 1.22
Structure Class II
Topographic Category 1
Crest height , H 0 m
Topographic Factor, Kzt 1.00
Directionality Factor, Kd 0.85
Importance Factor 1
Velocity Pressure, qz 1.26 Kpa
EPA Calculation of Tubular Pole

Gust Effect Factor 0.85


Structure Height 6 m
Pole Outside diameter, D 0.088 m
C value 4.33
Force Coefficient, Cf 1.20
Area of Pole, Ap 0.528 m2
EPA 0.63 m2
Design Wind Force, Fst 0.68 kN
Design Wind Force/m run 0.11 KN/m

EPA Calculation of Appurtances (Flat Panel)


Antenna Name GSM 2G
Wind Angle 0 Deg 0.00 Radians
Antenna Dimensions
Length ,L 2.45 m
Width, w 0.37 m
Depth, d 0.106 m
EPA Calculation
Ka 1
Aspect Ratio, (L/w) 6.62
Aspect Ratio, (L/d) 23.11
(Ca)n 1.38
(Ca)t 1.94
(EPA)n 1.25 m2
(EPA)t 0.50 m2
(EPA)a 1.254 m2
Design Wind Force, Fa 1.34 KN

EPA Calculation of Microwave Antennas

Antenna Name MW0.6


Outside Diameter of Microwave 0.675 m
Area of Aperture, A 0.358 m2
Wind Angle 0 Deg
Ca 1.5508 * Input Ca, Cs and Cm based on type of Antenna
Cs 0 and wind angle From Table C1 -C4, TIA 222G
Cm 0
Design Wind Force
FAM 0.59 kN
FSM 0 kN
MM 0 KNm

EPA Calculation of Feeder Cables

Wind Angle 0 Deg 0.00 Radians


Ka 1
Cable Diameter 30 mm
Total No Cables 18
No of Rows 3
Cables/ row 6
Clear spacing between cables 30 mm
Clear spacing between rows 30 mm
EPA considering Individual lines/m run 0.648 m2
(EPA)n considering Equ. Rect Appurtenance/m run 0.33 m2
(EPA)t considering Equ. Rect Appurtenance/m run 0.15 m2
(EPA)a 0.33
EPA Cables 0.33
Design Wind force/m run, Fs 0.35 KN/m
Exposure Category Zg α Kzmin Ke
B 366 7 0.7 0.9
C 274 9.5 0.85 1
D 213 11.5 1.03 1.1

Topographic Category Kt f Kh Kzt


1 1
2 0.43 1.25 #DIV/0! #DIV/0!
3 0.53 2 #DIV/0! #DIV/0!
4 0.72 1.5 #DIV/0! #DIV/0!

Structure Class Importance Factor


Wind
I 0.87
II 1
III 1.15

1.2
d on type of Antenna
le C1 -C4, TIA 222G
1.224262
1.224262
1.224262
Design of Tubular Pole structures Subjected to Axial, Moment, Shear and Torsion

Input Loads
Factored Axial Load, Pu 19 KN
Factored Moment, Mu 16 KNm
Factored Shear, Vu 20 KN
Factored Torsion, Tu 2 KNm

Properties of Section
Outer Diameter of Pole, D 42 mm
Thickness, t 5 mm
Inner Diameter, d 32
Modulus of Elasticity, E 2.00E+05 MPa
Yield Strength, Fy 275 Mpa
Area, A 580.9 mm2
Elastic Section modulus, S 4822.53 mm3
Plastic Section modulus, Z 6886.67 mm3
Polar Moment of Inertia, J 202546.3324

Calculation for Compressive Strength


D/t 8.40
Effective yield strength 275.00 Mpa
Compressive Strength, Pn 135.79 kN

Calculation for Flexural Strength


Moment Strength, Mn 1.70 kNm

Calculation for Shear Strength


Shear Strength, Vn 71.89 KN

Calculation for Torsional Strength


Torsional Strength, Tn 2.39 KNm

Check For Interaction

10.64 Unsafe
Design of Tubular leg members subjected to compression for latticed structures
Input Data
Factored Axial Compression 200 kN
Unsupported Length 400 mm
Properties of Section
Outer Diameter of Pole, D 42 mm
Thickness, t 5 mm
Inner Diameter, d 32 mm
Modulus of Elasticity, E 200000 Mpa
Yield Strength, Fy 275 Mpa
Calculation
Area, A 581.19 mm2
D/t 8.4
Effective yield strength 275.00 Mpa
K 1
Moment of Inertia, I 101273.17 mm4
Radius of Gyration, r 13.20 mm
Slenderness ratio, KL/r 30.30
λc 0.36
Fcr 260.66 Mpa
Allowable Compressive Strength 128.77 kN
Ratio 1.55 Unsafe, Revise section
Design of Tubular members subjected to axial compression and bending forces for Latticed Structures
Input Data
Factored Axial Compression 100 kN
Factored Moment 0.1 KNm
Unsupported Length 200 mm
Member Type Leg
P-Delta Effects Considered No
Properties of Section
Outer Diameter of Pole, D 42 mm
Thickness, t 5 mm
Inner Diameter, d 32 mm
Modulus of Elasticity, E 200000 Mpa
Yield Strength, Fy 248 Mpa
Elastic Section modulus, S 4822.53 mm3
Plastic Section modulus, Z 6886.67 mm3
Moment of Inertia, I 101273.17 mm4
Radius of Gyration, r 13.20 mm
Calculation
Area, A 581.19 mm2
D/t 8.40
Effective yield strength 248.00 Mpa
K 1 * Input K value from Table 4.3 to Table 4.5 based on
Slenderness ratio, KL/r 15.15 Member type and End conditions.
λc 0.17
Fcr 245.02 Mpa
Allowable Compressive Strength 121.05 kN
Allowable Moment Strength 1.54 kNm
Check for Interaction
Pu/φPn 0.83
B1 0.87
Amplified Factored Moment, Mu 0.09
Interaction 0.78 Safe
Minimum Bracing Resistance Check

Unsupported Length 515 mm


K value 0.7
radius of gyration 3 mm
Axial Design compressive force in
100 KN
supported member
Slenderness ratio, KL/r 120.17
Minimum Bracing resistance, Ps 2.50 kN
2.50