This document contains 6 questions related to electrical power systems topics like insulators, corona, and inductance. Question 4 asks to calculate the critical distributive voltage and critical voltage on a 3-phase transmission line. Question 5 asks if corona is a problem for a 3-phase line operating at 110kV with 1.25cm conductors spaced 3.05m apart. Question 6 asks to calculate the mutual inductance and induced voltage on a telephone line below a power line.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
130 views1 page
05 Worksheet PDF
This document contains 6 questions related to electrical power systems topics like insulators, corona, and inductance. Question 4 asks to calculate the critical distributive voltage and critical voltage on a 3-phase transmission line. Question 5 asks if corona is a problem for a 3-phase line operating at 110kV with 1.25cm conductors spaced 3.05m apart. Question 6 asks to calculate the mutual inductance and induced voltage on a telephone line below a power line.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Addis Ababa University 4.
Find the critical distributive voltage and the visual
Addis Ababa Institute of Technology critical voltage (general and local) on a 3-phase School of Electrical and Computer Engineering overhead transmission line, consisting of three stranded copper conductors spaced 2.5m apart at ECEG-3176: Introduction to Electrical Power Systems the corners of an equilateral triangle. Air Worksheet 05 Friday June 14, 2019 temperature and pressure are 21oC and 73.6mmHg By Heyab, Office N141 respectively. The conductor diameter=10.4cm, Objective: To understand insulators and corona irregularity factor=0.85, surface factor=0.7(local), 0.8(general) 1. A string insulator 4-units and each unit is having 5. Is corona a problem for a 3-phase line operating at capacitance C. The pin to earth capacitance is 0.1C. 110KV which has conductor of 1.25cm diameter Find the voltage across each unit of string and the arranged in equilateral triangle with 3.05m string efficiency. The line operates at 33KV. spacing. Assume air density factor δ=1.07 and dielectric strength of air 21KV/cm. 2. A string of eight insulators is to be graded to obtain uniform voltage distribution across the string. If 6. A single phase 50Hz power line is supported in a the capacitance of the top unit is 10 times the horizontal cross-arm. A telephone line is capacitance to ground of each unit, determine the supported symmetrically below the power line as capacitance of the remaining seven units. shown. Find the mutual inductance between the two circuit and the voltage induced per km in the 3. Determine the voltage across each disc of telephone line if the current in the power line is suspension insulators as percentage of the line 120A. d1=2.5m, d2=3.2m voltage to earth. The self and capacitance to ground of each disk is C and 0.2C respectively. The capacitance between the link pin and the guard ring is 0.1C and also find the efficiency of the string.