Switchboard Instruments: Types DQ, VDQ, DPR, DSM, Eq

The document provides information about switchboard instruments, including types DQ, VDQ, DPR, DSM, and EQ. Standard sizes include quadratic instruments from 48x48mm to 144x144mm and edgewise instruments from 48x24mm to 144x72mm. Slim edgewise instruments are also listed from 72x24mm to 144x36mm. Accuracy class is specified as 1.5 and scales are exchangeable on quadratic instruments.

Uploaded by

Ammar Raman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
237 views8 pages

Switchboard Instruments: Types DQ, VDQ, DPR, DSM, Eq

The document provides information about switchboard instruments, including types DQ, VDQ, DPR, DSM, and EQ. Standard sizes include quadratic instruments from 48x48mm to 144x144mm and edgewise instruments from 48x24mm to 144x72mm. Slim edgewise instruments are also listed from 72x24mm to 144x36mm. Accuracy class is specified as 1.5 and scales are exchangeable on quadratic instruments.

Uploaded by

Ammar Raman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Switchboard instruments

Types DQ, VDQ, DPR, DSM, EQ


4921210012J

• Standard DIN sizes

Quadratic instruments: Q48…Q144


DEIF A/S

Edgewise instruments: 48 x 24…144 x 72 mm

Slim edgewise instruments: 72 x 24…144 x 36 mm

• Accuracy class 1.5

• Exchangeable scale (quadratic instruments)


Contents
Special versions ...................................................................................................................................................... page 02
General technical specifications .............................................................................................................................. page 03
Quadratic moving coil instruments with/without rectifier .......................................................................................... page 04
Quadratic moving iron instruments........................................................................................................................... page 05
Edgewise moving coil instruments ........................................................................................................................... page 06
Slim edgewise moving coil instruments.................................................................................................................... page 07
Dimensional details .................................................................................................................................................. page 08

Available types
Quadratic instruments
48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm
Moving coil 90° DQ48-x DQ72-x DQ96-x DQ144-x
DQ48-c DQ72-c DQ96-c DQ144-c
Moving coil 240°
DQ48-xc DQ72-xc DQ96-xc DQ144-xc
- with rectifier 90° VDQ72-x VDQ96-x VDQ144-x
VDQ72-c VDQ96-c VDQ144-c
- with rectifier 240°
VDQ72-xc VDQ96-xc VDQ144-xc
Moving iron 90° EQ48-x EQ72-x EQ96-x EQ144-x
Edgewise instruments
48 x 24 mm 72 x 36 mm 96 x 48 mm 144 x 72 mm
Moving coil DPR48 DPR72 DPR96 DPR144
Slim edgewise instruments
72 x 24 mm 96 x 24 mm 144 x 36 mm
Moving coil DSM72 DSM96 DSM144

Special versions
General Antiglare glass
IP54 from front (incl. rubber gasket) (types DQ and EQ)
Adjustable red pointer (types Q48-x, Q72-x, Q96-x, Q144-x) (IP52)
Other measuring ranges than those stated in this data sheet
Scale Non-standard scale e.g. ammeter with 3, 4, 5 or 6 times overload range
Scale according to table or curve
Single scale with double row of figures (standard scale)
Double scale with 2 rows of figures (standard divisions)
Single scale with fine divisions for standard pointer
Red line at specified value
Coloured section for specific scale range
Additional text on scale, Roman types (e.g. "Generator")
Moving iron instruments Adjusted to a specified frequency, 100...500Hz
Adjusted for DC measurement
Adjusted to accuracy class 1.0
Moving coil instruments Suppressed zero (DQ..-x/DQ..-c/-xc: Max. 20%)
Zero at centre of scale or the like
Integrated adjustment potentiometer (±10% standard, up to ±50% on request)
Adjusted to accuracy class 1.0

Accessories: Blank covers types Q72, Q96, Q144


Blank covers are typically applied to cover panel cut-outs provided for later extension of the switchboard.
The blank covers consist of a standard bezel with spring clamp for mounting in the panel, mounted with a white, opal PVC
plate instead of glass. (Depth behind panel: Approx. 12 mm).

2
General technical specifications
Instruments are designed according to below mentioned standards Standards
Class 1.5 (-10...15...30...55°C)

Linear scales:
Accuracy ±1.5% of full scale value (FS) EN 60051 and IEC 51

Non-linear scales:
±1.5% of scale length
48 x 24 mm 72 x 24 mm 96 x 24 mm 144 x 36 mm
Instrument sizes 72 x 36 mm 96 x 48 mm 144 x 72 mm DIN 43700
48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm
Bezels Slim bezels DIN 43718

Standard pointer
Scale/pointer DIN 43802

Standard: Vertical (90 ±5°)

Other angles: Specify angle to horizontal

┴ vertical mounting

Mounting angle 60° 60° to horizontal DIN 16257


(e.g.)

Π horizontal mounting

For edgewise instruments only, furthermore specify:


Horizontal or vertical scale
See pages 4-7.
Measuring ranges DIN 43701
Others on request.
Protection Standard version IP54 version*
*
) Marked with label:
From front From rear From front From rear
"IP54 from front only
when rubber gasket is
(Housings) IP52 IP52 IP54 IP52
mounted"
Quadratic Edgewise Quadratic Edgewise
IEC 529 and EN 60529
(Terminals) IP20 IP00 IP20 IP00
Class HUE
Climate DIN 40040
Short-term condensing allowed
Max. 95% RH: Max. 30 days per year
Max. 85% RH: Remaining days
Max. 75% RH: Average per year
-10...55°C (nominal)
Temperature -25...60°C (operating) EN 60051 and IEC 51
-25...65°C (storage)
The accuracy is affected neither by the material nor by the
Panel influence EN 60051 and IEC 51
thickness of the panel
15g - 6 times - 3 directions
Shock test 50g/6ms IEC 68-2-27, Test: Ea
22g/20ms
3-13.2Hz: 3mm GL + LR: Test 1
Vibrations
13.2-100Hz: 1g DNV: Class A
Materials All plastic materials are self-extinguishing UL94 (V0)
600V – CAT. III
Pollution deg. 2
Safety EN 61010-1
Quadratic instruments are supplied with protective cover fitted
over terminals
CE classified for residential, commercial and light industry plus EN 50081-1/2 and
EMC
industrial environment EN 50082-1/2

3
Quadratic moving coil instruments
Application: Measurement of DC currents and DC voltages

Scale: Linear

Scale lengths: DQ48/72/96/144-x: 41/62/92/135 mm

DQ48/72/96/144-xc/-c: 75/113/151/230 mm

Accuracy: Class 1.5

Burdens: Voltmeters: 1mA, Ri: 1 kΩ/V

Ammeters: 60mV...0.5V

Ammeters: 4…20mA (see note 3 below)

Housings: Plastic

V 100 40 60 40 60

20 80 20 80
50

0 % 100 0 100
0

DQ96-x (exchangeable scale) DQ96-c (non-exch. scale) DQ96-xc (exchangeable scale)

1
Type Size (mm) Measuring range - V Measuring range - A 1
DQ48-x 48 x 48 60mV ... 600V 1mA ... 600mA 2, 4...20mA3
2 3
DQ72-x 72 x 72 60mV ... 600V 1mA ... 5-10-15-40A , 4...20mA
DQ96-x 96 x 96 60mV ... 600V 1mA ... 5-10-15-40A 2, 4...20mA3
2 3
DQ144-x 144 x 144 60mV ... 600V 1mA ... 5-10-15-40A , 4...20mA
2 3
DQ48-xc/DQ48-c 48 x 48 60mV ... 600V 1mA ... 600mA , 4...20mA
DQ72-xc/DQ72-c 72 x 72 60mV ... 600V 1mA ... 5-10-15-40A 2, 4...20mA3
2 3
DQ96-xc/DQ96-c 96 x 96 60mV ... 600V 1mA ... 5-10-15-40A , 4...20mA
DQ144-xc/DQ144-c 144 x 144 60mV ... 600V 1mA ... 5-10-15-40A 2, 4...20mA3

1) Standard measuring ranges: 1 - 1.2 - 1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 8 and multiples of 10 thereof

2) Higher measuring ranges: For use with standard shunt: 60mV or 150mV
Supplied with shunt lead, 2 x 1 m – 1 mm² (0.035Ω)

3) 4…20mA: Electrically suppressed, voltage drop at 20mA = 1.6V for -x and 1.80V for -c/-xc

Quadratic moving coil instruments with rectifier


Application: Measurement of AC currents and AC voltages. Measures average value,
calibrated to R.M.S. value at sinusoidal current/voltage

VDQ.. Voltmeters 25...600V: Ri: Approx. 1kΩ/V. Range <50V AC: Scale non-linear

VDQ.. Ammeters 1...600mA: Voltage drop: Approx. 1.2V

Order specifications
1
Type/point of rotation of pointer Measuring range Scale
Examples: DQ96-x 0...10V DC 0...100%
VDQ96-x 0…100V AC 0…100V

"-x": Lower right corner, exchangeable scale, “-c”: Centre, "-xc": Centre, exchangeable scale

4
Quadratic moving iron instruments
Application: Measurement of AC currents and AC voltages, adjusted for frequency range
16..65Hz. Calibration for other frequency ranges (see page 2). The instruments
measure true R.M.S.

Working range: Ammeters are designed with a 2 times overload range. The instruments will
withstand starting currents up to 10 times normal load for 5 secs and 5 times
continuously

Scale range: The scale is standard designed with a 2 times overload range (non-standard scale
– see page 2)

Scale lengths: EQ48/72/96/144-x: 41/62/92/135 mm

Accuracy: Class 1.5

Burdens: Voltmeters: Approx. 1.5...4VA


Ammeters: Approx. 0.5...1.2VA

Housings: Plastic

V 100 A 60
120

40
50

20

0 0

EQ96-x (ammeter)
EQ96-x (voltmeter)

1
Type Size (mm) Measuring range - V Measuring range - A 1

40V ... 600V 3 2


EQ48-x 48 x 48 1A ... 25A
EQ72-x 72 x 72 40V ... 800V 3 1A ... 60A 2
3 2
EQ96-x 96 x 96 40V ... 800V 1A ... 60A
EQ144-x 144 x 144 40V ... 800V 3 1A ... 60A 2

1) Standard measuring ranges: 1 - 1.2 - 1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 8 and multiples of 10 thereof

2) Higher measuring ranges: For use with external current transformer, -/5A, -/1A

3) Higher measuring ranges: For use with external voltage transformer, -/100V (-/110V)

Exchange of scale, quadratic instruments

1) Press cover at top of instrument as shown


2) Remove scale by means of a suitable tool (e.g. screwdriver)
3) After exchange of scale: Refit cover (press till it snaps into place)

Note: Interrupt signal to terminals before exchanging the scale.

Order specifications
Type Measuring range Scale
Example: EQ96-x 0...500A AC, 500/1A 0...500A x 2

5
Edgewise moving coil instruments
Application: Measurement of DC currents and DC voltages

Scale: Linear

Accuracy: Class 1.5

Burdens: Voltmeters: 1mA, Ri: 1kΩ/V


Ammeters: 60mV...0.5V

Housings: Plastic

1
Type Size (mm) Measuring range - V Measuring range - A 1

DPR48 48 x 24 1V ... 600V 1mA ... 600mA 2, 4...20mA


DPR72 72 x 36 1V ... 600V 1mA ... 600mA 2, 4...20mA
2
DPR96 96 x 48 1V ... 600V 1mA ... 600mA , 4...20mA
DPR144 144 x 72 1V ... 600V 1mA ... 600mA 2, 4...20mA

1) Standard measuring ranges: 1 - 1.2 - 1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 8 and multiples of 10 thereof

2) Higher measuring ranges: For use with standard shunt: 60mV or 150mV
Supplied with shunt lead, 2 x 1 m – 1 mm² (0.035Ω)

Order specifications
Type Scale type/Mounting 1 Measuring range Scale
Example: DPR96 Horizontal 4...20mA DC 0...10 bar
1
) Horizontal or vertical scale

6
Slim edgewise moving coil instruments
Application: Measurement of DC currents and DC voltages

Scale: Linear

Scale lengths: DSM72/96/144: 52/70/95 mm

Accuracy: Class 1.5

Burdens: Voltmeters: 1mA, Ri: 1kΩ/V


Ammeters: 60mV...0.5V

Housings: Plastic

1
Type Size (mm) Measuring range - V Measuring range - A 1

DSM72 72 x 24 60mV ... 600V 1mA ... 600mA 2, 4...20mA


2
DSM96 96 x 24 60mV ... 600V 1mA ... 600mA , 4...20mA
DSM144 144 x 36 60mV ... 600V 1mA ... 600mA 2, 4...20mA

1) Standard measuring ranges: 1 - 1.2 - 1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 8 and multiples of 10 thereof

2) Higher measuring ranges: For use with separate standard shunt: 60mV or 150mV
Supplied with shunt lead, 2 x 1 m – 1 mm² (0.035Ω)

Order specifications
Type Scale type/Mounting 1 Measuring range Scale
Example: DSM144 Horizontal 0...20mA DC 0...300A
1
) Horizontal or vertical scale

7
Dimensional details
Quadratic instruments (90° and 240°)

1) For range 15…40A = 59 mm

2) Protective power

All dimensions in mm
Type A C B Panel cut-out Weight (approx.)
90° Moving coil and moving iron instruments
Q48-x 48 x 48 5.0 42.8 x 48.8 45 x 45 +0.3 0.090 kg
Q72-x 72 x 72 5.5 66.5 x 66.5 68 x 68 +0.4 0.200 kg
Q96-x 96 x 96 5.5 90 x 90 92 x 92 +0.4 0.210 kg
Q144-x 144 x 144 8.0 136 x 136 138 x 138 +0.5 0.350 kg
240° Moving coil instruments
DQ48-xc/c 48 x 48 5.0 42.8 x 48.8 45 x 45 +0.3 0.180 kg
DQ72-xc/c 72 x 72 5.5 66.5 x 66.5 68 x 68 +0.4 0.220 kg
DQ96-xc/c 96 x 96 5.5 90 x 90 92 x 92 +0.4 0.250 kg
DQ144-xc/c 144 x 144 8.0 136 x 136 138 x 138 +0.5 0.400 kg
Edgewise moving coil instruments

All dimensions in mm
D+E
Type A B C E F1 x F2 G H Panel cut-out Weight (approx.)
(max.)
DPR48 48 x 24 3 5 75 8 45 x 18 53 34 45 +0.6 x 22.2 +0.3 0.050 kg
DPR72 72 x 36 4 5 99 9 66 x 32.5 79 34 68 +0.7 x 33.0 +0.6 0.100 kg
DPR96 96 x 48 4.5 5.5 143 7 91 x 43 104 17 92 +0.8 x 45.0 +0.6 0.450 kg
DPR144 144 x 72 5.5 8 192 3 136 x 66 150 17 138 +1.0 x 68.0 +0.7 0.950 kg
Slim edgewise instruments

All dimensions in mm
H
Type A B C D E F1 x F2 G Panel cut-out Weight (approx.)
(max)
DSM72 72 x 24 3.5 x 5 6 90 8 17 x 65 75 40 68 + .7 x 22.2 +0.3 0.080 kg
DSM96 96 x 24 3.5 x 5 6 110 8 17 x 89 99 40 92 +0.8 x 22.2 +0.3 0.100 kg
DSM144 144 x 36 4 x 6.5 7 164 9 32 x 137 147 40 138 +1.0 x 33.0 +0.6 0.240 kg

Due to our continuous development we reserve the right


to supply equipment which may vary from the described.