0% found this document useful (0 votes)
205 views

Mathcad - 14-Design of Short Column (Rectangular)

The document provides information to design a short rectangular column subjected to an axial load of 5540.4 kN and bending moment of 40 kN-m. It calculates the required column dimensions of 800x400 mm and reinforcing steel area of 88.357 cm^2 in 4 rows to satisfy the load requirements while meeting code specifications for minimum reinforcement and strength reduction factors. An interaction diagram is generated to check the column capacity under various eccentric load conditions.

Uploaded by

MrAlittle Finger
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
205 views

Mathcad - 14-Design of Short Column (Rectangular)

The document provides information to design a short rectangular column subjected to an axial load of 5540.4 kN and bending moment of 40 kN-m. It calculates the required column dimensions of 800x400 mm and reinforcing steel area of 88.357 cm^2 in 4 rows to satisfy the load requirements while meeting code specifications for minimum reinforcement and strength reduction factors. An interaction diagram is generated to check the column capacity under various eccentric load conditions.

Uploaded by

MrAlittle Finger
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Workout Example Design of Short Column (Rectangular)

Load on column Pu  5540.4kN

Moment M u  40kN m

Compressive strength of concrete f'c  30 MPa

Yeild strength of reinforcement fy  390  MPa

5
Modulus of elasticity of steel Es  2  10 MPa

Material Assumption

Strength reduction factors ϕ  0.65

Maximum Compressive Strain in concrete ε u  0.003

Cover to transversal reinforcement CL  40mm

Diameter of tensile reinfocement D  25mm

Diameter of stirrup reinforcement Dv  10mm

Material Assumption

Solution
Required column section

ρg  0.03

Pu 2
Ag  Ag  2924.28  cm
 
0.80 ϕ 0.85 f'c 1  ρg  fy  ρg
 

200cm Ag
k  h  b  k  h
400cm k

h  ceil   50mm  0.8 m


h
 h  800  mm
 50mm 

b  ceil   50mm  0.4 m


b
 b  400  mm
 50mm 
2
Ag  b  h Ag  3200 cm
Required steel area

Pu
 0.85 f'c Ag
0.80 ϕ 2
Ast  Ast  68.439 cm
0.85 f'c  fy

ORIGIN  1

Re-bars in rows Re-bars area in rows

1 1 1 1  19.635 
   
1 0 0 1  9.817 
1 0 0 1 cols( DB) 2  9.817 
i π D
DB   1 1   9.817   cm

2
0 0 As  DB 
  4  
1 0 0 1 i 1  9.817 
1 0 0 1  9.817 
1   19.635 
 1 1 1  

Provided steel area

 As  88.357cm
2
Ast 

Effective Layer
D
d'  CL  Dv   6.25 cm
2

d  d  d'  62.5 
1  
for i  2  rows( DB)  175 
 287.5 
h  2 d
S
1 d   400   mm d t  max( d )  73.75  cm
rows( DB)  1  
 512.5 
d d S  625 
i i 1
 737.5 
d  
Interaction diagram for column strength
Equivalent depth factor
β1  0.85 if f'c  27.6MPa β1  0.833 (ACI.10.2.7.3)

0.65 if f'c  55.2MPa

f'c  27.6MPa
0.85  0.05 otherwise
6.9MPa
Compression strength
a = β1  c (ACI.10.2.7.1)
a d  c( a)
c( a)  i
β1 ε s( i a)  ε u 
c( a)
i  1  rows( DB)
  
fs( i a)  sign ε s( i a)  min ε s( i a)  Es fy  (ACI.10.2)

Cs( i a)  As  fs( i a) Cc( a)  0.85 f'c a b


i

   
ϕPn.max  0.80 ϕ 0.85 f'c Ag  Ast  fy  Ast  5917.924 kN (ACI.10.3.6.2)

d t  c( a)
ϕ( a)  εt  εu
c( a)
0.9 if ε t  0.005

0.65 if ε t  0.002

 
250
0.65  ε t  0.002  otherwise
3

  rows( DB )  
ϕPn ( a)  minϕ( a)   Cc( a)  Cs( i a)  ϕPn.max
    
  i 1  

 rows( DB ) 
ϕPn.max( a)  ϕ( a)   Cc( a)  Cs( i a) 
  
 i 1 

 rows( DB ) 
ϕMn ( a)  ϕ( a)  Cc( a)  
a C ( i a)   d  h 

h
    s  i 
 2 2   2 
 i 1 
M 2.min  Pu  ( 15mm  0.03 h )  216.076  kN m


M u  max M u M 2.min  216.076  kN m 
h
a  0   1.06 h
300
Mu e
e   39 mm Eccentricity  0.049
Pu h
Interation Diagram
6000

Axail Load Strength 4800


ϕPn( a)

kN 3600

Pu
2400
kN
1200

0
0 300 600 900 1200 1500
ϕMn( a) Mu

kN m kN m

With Norminal Interation Diagram

ϕPn( a)

kN

ϕPn( a)
Axail Load Strength

kN

ϕPn.max( a)

ϕ( a)  kN

ϕPn.max( a)

ϕ( a)  kN

Pu

kN

ϕMn( a) ϕMn( a) ϕMn( a)  ϕMn( a) Mu


   
kN m kN m ϕ( a)  kN  m ϕ( a)  kN m kN m

Bending Moment
Stength of Column with Strength Reduction Factor

Stength of Column without Strength Reduction Factor

External Load