Span/Eff - Depth Ratio Fs Modification Ten. Factor Modification Com. Factor Actual Span/effe - Depth Allowable Span/eff. Depth Long Span Factor
Span/Eff - Depth Ratio Fs Modification Ten. Factor Modification Com. Factor Actual Span/effe - Depth Allowable Span/eff. Depth Long Span Factor
Cover = 25 mm
Effective length = 3.00 m
Concrete fcu = 35 N/mm2
Tension bar dia = 16 mm
H = 200 mm
Effective depth d = 167 mm
b = 1000 mm
Tension Bar
Moment M = 45 kNm
k = 0.04610 < 0.156 Ok
z = 157.96
Area required = 711.9 mm2
Area provided = 1005 mm2 Provide T 16 - 5 Ok
Spacing T 16 - 200
Compression Bar
Min. area required = 260.0 mm2
Area provided = 393 mm2 Provide T 10 - 5 Ok
Spacing T 10 - 200
Shear check
Shear = 125 kN
V = 0.75 N/mm2 < 4.73 N/mm2 Ok
100As/bd = 0.60
400/d = 2.40 N/mm2
vc = 0.74
Deflection Check
Span/Eff.depth Ratio = 20.00
fs = 203.58
modification ten. factor = 1.46
modification com. factor = 1.00
Actual span/effe.depth = 17.96 passed!
Allowable span/eff. depth = 29.13
Long span factor = 1.00