0% found this document useful (0 votes)
461 views

Modeling: UPT - XU - 1000 - STD - 01 Type Input Coupling

This document provides information about a universal pulse transmitter model UPT-1000-STD-01. It includes details about the transmitter type, housing, resolution, input coupling, and available pulses per volume unit depending on the meter gearing. The transmitter can output between 100-1000 pulses per volume unit measured, depending on the specific model. It is designed to interface with various flow meter outputs to provide a pulse output proportional to flow volume.

Uploaded by

Nhat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
461 views

Modeling: UPT - XU - 1000 - STD - 01 Type Input Coupling

This document provides information about a universal pulse transmitter model UPT-1000-STD-01. It includes details about the transmitter type, housing, resolution, input coupling, and available pulses per volume unit depending on the meter gearing. The transmitter can output between 100-1000 pulses per volume unit measured, depending on the specific model. It is designed to interface with various flow meter outputs to provide a pulse output proportional to flow volume.

Uploaded by

Nhat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Modeling

UPT — XU — 1000 — STD — 01


Type

UPT - Universal Pulse Transmitter Input Coupling5

00 - S1 (E3 Through H8, E3-S3, S5)7


Housing 01 - S3 and S5 (C2, F4 Through H8)7
02 - S6 and S7 (C2 Through M16)
XU - Explosion-Proof, UL/CUL, ATEX and 03 - S1, S3, and S5 (JA/JB10, K12, and M16)
IECEx 04 - C2-S1 and SC-13 Gallons
05 - C2-S1 and SC-13 Dekalitres
06 - SD Meters and T-40 Gallons
High-Frequency Pulse Resolution4 07 - SD Meters and T-40 Dekalitres
1000 - 1,000 Pulses
Trim Package
500 - 500 Pulses
250 - 250 Pulses STD - Standard
200 - 200 Pulses
100 - 100 Pulses

Table 1
Transmitter Models / Available Pulses per Volume Unit6
Meter Gearing UPT-1000 UPT-500 UPT-250 UPT-200 UPT-100
1:1 Gallons 1,000 pulses/gal 500 pulses/gal 250 pulses/gal 200 pulses/gal 100 pulses/gal
5:1 Gallons1 200 pulses/gal 100 pulses/gal 50 pulses/gal 40 pulses/gal 20 pulses/gal
1:1 Barrels 1,000 pulses/bbl 500 pulses/bbl 250 pulses/bbl 200 pulses/bbl 100 pulses/bbl
1:1 Dekalitres 1,000 pulses/dek 500 pulses/dek 250 pulses/dek 200 pulses/dek 100 pulses/dek
5:1 Dekalitres 200 pulses/dek 100 pulses/dek 50 pulses/dek N/A N/A
10:1 Dekalitres 100 pulses/dek 50 pulses/dek N/A N/A N/A

1 U.S. Gallons unless specified Imperial Gallons.


4 Pulses per revolution of input shaft.
5 This coupling mates with output of meters listed.
6 Nominal pulses per volume are based on meter with 100% gearing.
7 The 00 coupling is required for F4-S1 models pre-2008 (see parts list). The 01 coupling is required for F4-S1 models 2008-present.