Data sheet for MICROMASTER 440
MLFB-Ordering data
6SE6440-2UD42-0GA1
Figure similar
Client order no. : Item no. :
Order no. : Consignment no. :
Offer no. : Project :
Remarks :
Rated data General tech. specifications
Input Power factor λ 0.95
Number of phases 3 AC Efficiency η 0.97
Line voltage 380 ... 480 V ±10 % Ambient conditions
Line frequency 47 ... 63 Hz Cooling Fan
Rated current (LO) 442.00 A
Ambient temperature
Rated current (HO) 354.00 A Operation (LO) 0 ... 40 °C
Output Operation (HO) 0 ... 40 °C
Number of phases 3 AC Transport -40 ... 70 °C
Rated voltage 480 V Storage -40 ... 70 °C
Rated power (LO) 250.00 kW / 350.00 hp
Rated power (HO) 200.00 kW / 300.00 hp
Rated current (LO) 477.00 A
Rated current (HO) 370.00 A
Pulse frequency 4000 Hz
Output frequency for V/f control 0 ... 267 Hz
Overload capability
Low Overload (LO)
150 % output current for 1 s, followed by 110 % output current for 59 s followed by 100 % output current for 240 s in a 300 s cycle time
High Overload (HO)
136 % output current for 57 s, followed by 100 % output current for 243 s in a 300 s cycle time
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 1 of 2 Generated Thu Mar 21 05:44:00 CET 2019
Data sheet for MICROMASTER 440
MLFB-Ordering data
6SE6440-2UD42-0GA1
Figure similar
Mechanical data Connections
Degree of protection IP20 / UL open type Motor end
Size FSGX Conductor cross-section 240.00 mm²
Net weight 174.00 kg
Width 326.0 mm
Height 1533.0 mm
Depth 545.0 mm
Inputs / outputs
Standard digital inputs
Number 6
Relay output
Number 3
Analog inputs
Number 2
Analog outputs
Number 2
PTC/ KTY interface
Number 1
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.