Explosion Protection & Harsh Environment Explosion Protection & Harsh Environment
Explosion Protection & Harsh Environment Explosion Protection & Harsh Environment
Harsh Environment
www.patlite.com
“New Frontiers in Safety, Security and Comfort” is
PATLITE`s mission.
PATLITE offers state-of-the-art equipment for process and ■ From designing to production, quality control
industrial automation for over 60 years. Our Innovative and robust is managed throughout the process
design, backed by a powerful commitment and years of
knowledge, has made PATLITE the world’s best known
manufacturer of the visual and audible signaling products.
We are also dedicated to the development of explosive and
harsh-environment products to demonstrate our strong
commitment to serving the industry with unique and innovative
Design with 3-D CAD Manufacturing of metal Electrical discharge machine
solutions. molding parts
1
2 rue René Laennec 51500 Taissy France E-mail:[email protected]
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 Site web : www.hvssystem.com
■ How Explosion Occurs
An explosion can only occur if there is a combination Prerequisites for an explosion
of the following three factors.
● Source of ignition
● Oxygen
Combustible Oxygen
● Combustible substances Substancesl
Combustible substances can exist in the form of gases,
vapor, mist or dust. If one component is missing, no
explosion will take place. Explosion
Zone 1
An area where an explosive atmosphere consisting of a mixture of
air containing flammable substances in the form of gas, liquid, or
vapor can occasionally occur during normal operating conditions.
Zone 2
Saw Dust
Woodworking Industry
Fine Wood Chips
Alcohol Solvents
Pharmaceutical Industry
Materials explosive when mixed
Flammable Gases
Chemical Industry Flammable Liquids
Flammable Solids
3
Classification of Hazardous Areas
■ Gases/Vapors
The tank is filled with flammable liquid. The inside of the tank is The vapor may also run down the outside of the tank,
defined as zone 0, because the explosive gas/oxygen mixture is developing another explosive environment, so the area around
continuously present. the tank is categorized as Zone 2.
Vapor may escape on occasion through the vent on the top of
the tank, therefore the area around the vent is categorized as
Zone 1.
Gases/Vapors
■ Dust
At a mill with a feed hopper and filter: A product, which causes causes a potentially explosive compound in the area where the
dust particles mixed with sufficient air to cause an inflammable product is loaded into the hopper, so the area outside the hopper
mixture, is loaded into a hopper. is categorized as Zone 21.
Inside the feed hopper and filter, it is categorized as Zone 20. Around the hopper where a potential inflammable atmosphere
While the product is being loaded, the mixture of dust and air exists temporarily is categorized as Zone 22.
Explosive
Equipment Category
Standards Atmosphere: Group
Group
Gas or Dust
<International Standards>
IEC Ex de IIC T4 Gb
<E.U. Standards>
Ⅱ 2 G Ex de IIC T4 Gb
CENELEC ATEX Directive 94/9/EC
<U.S. Standards>
NEC 505 Class 1, Zone 1 AEx de IIC T4 Gb
Temperature
Types of Class (max.
Zone 0, 1, 2 Gas Group EPL
Protection surface
temperature)
The entrance of dust is not closed completely, but dust No detrimental effect occurs when water is sprayed onto the test
may not go into the device in such manner as to impair sample by a jet-stream from any direction. (TEST: 100 liter/min. of
5 6 water is sprayed with a jet nozzle, having an internal diameter of
the optimal operation or safety of the device.
12.5mm, with a distance of 2.5m - 4m away from the test sample)
Water must not enter into the device. No detrimental effect occurs
7 when the device is submerged in a depth of 1 meter of water for 30
minutes.
Water must not enter into the device. No detrimental effect occurs
when the device is continuously submerged. The test conditions are to
6 No intrusion of dust into the device occurs. 8 be mutually agreed upon by the manufacturer and user.
IP69K is the German DIN 40050 PART9 standard. It is defined as a protection regulation for high temperature and high-pressurized water. Water is
heated up to 80 ゚C and sprayed at a water pressure in the range from 80 to 100 bars at 14 to 16 liters per minute at the test object. The test object is
IP69K at a distance of 100 to150 mm from the nozzle and sprayed in all directions at 0, 30, 60, and 90 degrees, then sprayed at a horizontal angle while it is
being rotated, all done for a period of 30 seconds without being affected by water penetration.
10-15cm
5
Types of Protection
According to EN Standard Series EN 60079, explosion protected electrical equipment can have various types of protection according to its construction.
The table below for Gas and Dust shows an overview of the standardized protections and describes its basic principal, as well as its practical applications.
Select the suitable PATLITE explosion-safe and intrinsically-safe products according to the specific application and type of protection.
Gas
Type of Protection Marking Diagram Definition Applications PATLITE Model
General requirements
EN 60079-0
IEC 60079-0
Parts which can cause ignition while in a potentially explosive Switch Gear, Control Gear,
Flameproof Enclosure "d" environment are encased in an enclosure which can withstand Display Units, Control Systems, EDLM Series
EN 60079-1 Ex d the pressure to contain it when the explosive mixture ignites Motors, Transformers, EDWM Series
inside so it is not transmitted into the environment. Heating Equipment, Light Fittings
IEC 60079-1
Preventative safety precautions are applied to prevent the Terminal Boxes, Connection Boxes,
Increased Safety "e" possibility of excessive temperatures, the occurance of sparks or Control Boxes (for installing Ex-components with
EN 60079-7 Ex e electrical arcing within the equipment enclosure or on exposed different types of protection)
parts of the equipment that would not be a hazard in conditions Squirrel-cage Motors, Light Fittings
IEC 60079-7
where ignition sources are not present.
Inside the enclosure, a positive internal pressure in relation to Switch Gear, Control Cabinets, Analyzers,
Pressurized Enclosure "p□" the surrounding atmosphere is maintained with the supply of a Large Motors.
EN 60079-2 Ex p constant flow of protective gas (when necessary) to dilute any
px = use in Zone 1, 2
py = use in Zone 1, 2
IEC 60079-2 combustible mixtures. pz = use in Zone 2
AR-070 Series
All Electrical Equipment for Zone 2 AR-078 Series
nA = non-sparking equipment
Type of Protection "n□" Ex nA Electrical equipment cannot cause the ignition of a potentially LKEH-FV-EX Series
nC = sparking equipment in which contacts are
explosive atmosphere (defined under abnormal operating LKEH-FE-EX Series
EN 60079-15 Ex nR conveniently protected
nL = energy-limited equipment EWH-24E-J-EX
conditions and during normal operation).
IEC 60079-15 Ex nL nR = restricted breathing CLN-24-CD-PT-EX
CLK-EX Series
CLA-EX Series
Dust
Type of Protection Marking Diagram Definition Applications PATLITE Model
General requirements
EN-IEC 60079-0
IEC 60079-0
EDLM Series
EDWM Series
Dust is incapable of ingressing the enclosure at all or the Switch Gear, Control Gear,
AR-070 Series
Protection by Enclosures "t" quantity is at a safe degeree, which allows the ignitable AR-078 Series
Connections, Terminal Boxes,
EN-IEC 60079-31 LKEH-FV-EX Series
Ex t equipment to be mounted inside. The surface temperature of Motors, Light Fittings.
LKEH-FE-EX Series
the enclosure will not cause ignition to the surrounding td A21 = According to Method A for Zone 21
IEC 60079-31 td B21 = According to Method B for Zone 21
EWH-24E-J-EX
explosive atmosphere. CLN-24-CD-PT-EX
CLK-EX Series
CLA-EX Series
Pressurized Enclosure "pD" Inside the enclosure, a positive internal pressure in relation to
the surrounding atmosphere is maintained with the supply of a
EN-IEC 61241-4 Ex pD constant flow of protective gas (when necessary) to dilute any
Pumps
6
Zone 1, Zone 2, Zone 21, Zone 22
The EDLM and EDWM series offer wide range of voltages and
versatile mounting options to meet various applications.
The following chart explains the comparison between the ATEX
Directive 94/9/EC (CENELEC standard) and NEC Article 505
certification. To find the most suitable models, refer to page 9
and 10.
■ Standard Markings
Marking for ATEX Directive (CENELEC Standard) Markings for North America (NEC Standards)
CE 0000 Ⅱ 2 G NEC505 (Zone System)
CE Marking Type of Explosive Environment Class I, Zone1, A Ex d ⅡC T6
Notified Body Number Category
ATEX Directive Marking Equipment Group Flammable Gas or Vapor Temperature Code
Area Classification Gas Group
Ex d ⅡC T6 American National Standard Protection Method
Explosion-Protected Temperature Code Explosion Protection
Type of Protection Gas Group
NEC500 (Division System)
Ex tD A21 IP66 T80℃
Explosion Protection Temperature Class
Class I, Division1, Groups A,B,C,D, T6
Dust Protection Codes (only type of Ex tD)
Protection Method Dust Area Classification (only type of Ex tD) Flammable Gas or Vapor Area Classification Gas Group Temperature Code
■ ATEX Directive (CENELEC) ■ ATEX/IEC Classification for Gases & Temperature Coding
Equipment Category- Explosive Flammable Hazardous T1 T2 T3 T4 T5 T6
Group Protection Level Environment Substances Areas (450℃) (300℃) (200℃) (135℃) (100℃) (85℃)
Constant Ⅰ Methane
M1- Very High Level
Exposure Methane
Ⅰ-mines Acetone Ethyl Alcohol Gasoline
Ocassional Coal Dust
M2- High Level ⅡA Ethane Cyclohexane Aircraft fuel Acetaldehyde
Exposure
Propane n-butane Diesel fuel
Constant Gases Zone 0 (Gases)
1- Very High Level Ethylene
Exposure Zone 20 (Dust) Lighting Ethylene
Glycol
Vapors gas Ethyl-ether
Ⅱ-other Ocassional Zone 1 (Gases) ⅡB Ethylene
2- High Level Hydrogen
areas Exposure Zone 21 (Dust) Acrylonitrile oxide
Mists sulphide
Rare and Zone 2 (Gases) Carbon
3- Normal Level Temporary Dust ⅡC Hydrogen Acetylene
Zone 22 (Dust) bisulfide
7
Zone 2, Zone 22
CLA-EX Series
CLN-24-CD-PT-EX
EWH-24E-J-EX
MP3 Field Programmable Annunciator integrated with LED tower Hazardous Area
Model Selection Page CENELEC Standard Explosion Safety Gas Dust
LKEH-FV-EX Series 13 EN 60079-0, EN 60079-15, EN 60079-31 CE II 3GD Ex nA IIC T4 Gc, Ex tc IIIB T85°C Dc IP54 Zone2 Zone22
LKEH-FE-EX Series 13 EN 60079-0, EN 60079-15, EN 60079-31 CE II 3GD Ex nA IIC T4 Gc, Ex tc IIIB T85°C Dc IP54 Zone2 Zone22
■ Markings
0123 II 2 G Ex d IIC T6 Gb
EPL
Type of Ex Atmosphere Temperature Class
G ....... Gas (Maximum Surface Temperature)
D ....... Dust T1 ..... 450℃
T2 ..... 300℃
Equipment-Category T3 ..... 200℃
M1 ..... very high safety level (Mines) T4 ..... 135℃
M2 ..... high safety level (Mines) T5 ..... 100℃
1 ........ very high safety level T6 ..... 85℃
2 ........ high safety level
3 ........ normal safety level Gas Group
I ........ Methane(fire damp)
Equipment-Group IIA ..... Propane & equivalent
I ......... For mining installations IIB ..... Ethylene & equivalent
II ........ For industrial installations IIC ..... Hydrogen & Acetylene
Specific mark for explosion protection IIIA ......Fiber Flyings
IIIB ......Non-conductive dust
Registration number of Notified
Body certified the IIIC ......Conductive dust
QA system (if applicable). Protection degree against ignition
d ....... Flameproof Enclosure
Quality mark for compliance with the
EU directives, as a product passport to the e ....... Increased Safety
European Market (not for components). ia/ib/ic .......... Intrinsic Safe
ma/mb/mc.... Moulded Encapsulation
nA ..... Non-sparking
nC ..... Separated
nL ..... Energy Limited
nR ..... Restricted Breathing
o ....... Oil Immersion
px/py/pz ....... Purged/Pressurized
q ....... Powder Filling
Explosion Safe
8
Zone 1, Zone 2, Zone 21, Zone 22
■ Features
Horizontal Mount Housing: Aluminum alloy
Glass: Borosilicate glass
Terminals: Easy wire connection to the Signal Tower by opening the bottom
Mounting: Upright, Wall Mount, Vertical-mount, and Horizontal Mount
LED color: Different color configurations are possible to custom-design
EDLM EDWM Voltage: 24VAC/DC, 120VAC, 230VAC, 90-250VAC are available.
Vertical Mount Wire core size: 0.5mm2~0.8mm2, AWG20~AWG18
■ EDLM & EDWM are convered by the specifications shown in the shaded areas below
Common Standards for Europe The ATEX directive is a CENELEC standard.
PATLITE Constant Occasional Rare and
Classification Standard Models Exposure Exposure Temporary
Common Standards for the USA NEC is a National Electrical Code standard for North America.
PATLITE Constant Occasional Rare and
Classification Standard Models Exposure Exposure Temporary
9
Testing Authority PTB, NEC Article 505 Testing Authority
φ4.4
(Wall-mount)
Upper case 3/4 NPT
(31)
Indicator
283
347
Glass case
(24)
335
(415)
φ120
Lower case
*ATEX Model ... Included
*NEC Model ...... Not Included
347
Lead-in port 2 Lead-in port 1
3/4 NPT 3/4 NPT
126
■ Flush-mount Bracket
12
(48)
(48)
9
56
5
Earth terminal
15
218
O-ring M4 Screw
92
56
(86) (100) φ
11
56
φ
0
14
9
φ
φ
φ
38
(Horizonal-mount) 15
11
9
Plug
50
9
Cover
4
56
56
Cable gland 50
※Use for ATEX Directive.
Terminal block
218 (Unit: mm)
Setscrew
(Unit: mm)
Brown
Green
Yellow
Gray
Red
Power
Brown
Green
White
Yellow
R Y G C 1 2
Gray
Blue
Red
source
external protection fuse
1A
Continuous light L L L L L F V V
R Y G B W C 1 2 Power
Outer contacts source
Yellow
Brown
Green
Gray
Black
Red
Yellow
Brown
L L L C F V V
Green
White
Power
Blue
Black
Gray
Red
R Y G C C 1 2 source
external protection fuse
L L L L L C F V V 1A
R Y G B W C C 1 2
Power
Continuous light source
PWR wire Outer contacts
Continuous light
PWR wire PWR wire Outer contacts
Flashing COM Flashing
PWR wire
Flashing COM
Continuous COM Flashing
Outer contacts Continuous COM
Outer contacts
LED Green LED White
LED Blue
LED Amber
LED Green
LED Red LED Amber
LED Red
※120,230-240V only
<external protection fuse> All model : 250V 1A <external protection fuse> All model : 250V 1A
■ Features
Explosion-safe for gas and dust 1 to 5 stack are available
Suitable for Zone 2 and Zone 22 1/2” NPT adapter for pole mount is available as an option
1/2 inch NPT
CE compliance in accordance to ATEX Available with “flashing/non flashing” and two audible ※1/2 inch NPT adapter is also available
Full and brilliant lumination buzzer alarm sounds
LED double reflection lighting system Ingress protection of IP65
Different lens colors available Wall mount or direct mount
Side mount bracket
■ Dimensions ■ Specifications
Explosion-safety: II 3 GD; Ex nA IIC T4 Gc: Ex tc IIIC T85 ℃ Dc IP65
CE conformities: EN 60079-0, EN 60079-15, EN 60079-31
SIGNAL LIGHT
Certification: EC-Declaration of conformity
Ambient Temperature: -30 °C to +60 °C
Ingress Protection: IP65 to EN 60529
Material: ABS towerbody
Lighting Source: Multiple LEDs with double reflection system
Acoustical Source: Buzzer 85 dB (1m) with two different tones
Rated Voltage: 24V AC/DC
Assembly position: As desired
Activation Time: 100%
Module Colors Available: Red, Amber, Green, Blue, Clear/white
Cable: Factory sealed cable, Ø 8 mm, length 3 meter
CURRENT RATINGS
LED BUZZER
SIDE MOUNT BRACKET Signal Line Current
Signal Line Current Inrush Current
Red, Amber Green, Blue, Clear
approx. 30 mA approx. 25 mA approx. 40 mA approx. 250 mA
CONNECTION DIAGRAMS
TEMPLATE
Model Code AR-070- 0 1 / - RYGBC *Colors are arranged from top to bottom
※ 90∼250V AC Version is available by special order.
11
Zone 2, Zone 22
■ Features
Explosion-safe for gas and dust 1 to 5 stack are available
Suitable for Zone 2 and Zone 22 3/4” NPT adapter for pole mount is available as an option
3/4 inch NPT
CE compliance in accordance to ATEX Available with “flashing/non flashing” and ※3/4 inch NPT adapter is also available
Full and brilliant lumination two audible buzzer alarm sounds
LED double reflection lighting system Ingress protection of IP65
Different lens colors available Wall mount or direct mount
Side mount bracket
■ Dimensions ■ Specifications
Explosion-safety: II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85°C
CE conformities: EN 60079-0, EN 60079-15, EN 61241-0, EN 61241-1
SIGNAL LIGHT
Certification: EC-Declaration of conformity
Ambient Temperature: -30 °C to +60 °C
60 Ingress Protection: IP65 to EN 60529
12
M4
CURRENT RATINGS
70
31
CONNECTION DIAGRAMS
42
TEMPLATE
20
15
0°
12
4.5
R=20
4.5
1 Red R
Continuous lighting (only) 1 2 Amber Y
7
□:L Type
25
24V
1 1-5 3 N:NPT Type Green G
Continuous/Flashing lighting AC/DC
2 4 Blue B
and two Audible alarms 5 Clear/White C
35
Units: mm
Model Code AR-078- 0 1 / - RYGBC *Colors are arranged from top to bottom
※ 220V AC Version is available by special order.
12
Zone 2, Zone 22
105dB(A)
MP3 Field Programmable Announciator, Melody Horn
Explosion-safe for gas and dust
Suitable for Zone 2 and Zone 22 Insert SD card
CE compliance in accordance to ATEX into the slot.
Super bright LED colors correspond to different voice, sounds, Ultra bright
LED
chimes and melodies.
Voice alert messages of up to 63 seconds (64kbit/s) with 5 channels
can be played back.
32 combinations of sounds, chimes and melodies are pre-recorded.
8 sounds can be played back by a bit input, and 32 sounds by binary input.
Volume is adjustable from 0 to 105dB at 1 meter.
Field programmable with MP3 by SD card for the model LKEH-FV-EX.
Well visible with the super bright 100mm diameter LED from far distance.
105dB horn
Robust design to withstand against 2G vibration.
The body is made of Acrylonitrite-Ethylene-Styrene for weather resistant.
Easy to control by only one common wire for both LED units and
audible signals.
NPN is standard. PNP open collector type is also available on order.
LKEH-FV-EX, LKEH-FE-EX
°
20
12
1
0°
142
152 2-ø10
Front
Model MP3 Power
(mm) ・SD card for the model
400
350
LKEH-FEF-EX/LKEH-FEW-EX 14.2W LKEH-FVF-EX and
400 LKEH-FVW-EX
LKEH-FVF-EX/LKEH-FVW-EX Supports 14.2W
sold separately.
70
■ Model Code
110
142
142
φ7 (4x)
LKEH-302FVF-RYG-EX
Model Color
R: Red
60 20 Stack Y: Amber
200 100 1~4 G: Green
B: Blue
C: Clear/White
FV:Voice Synthesizer F: Flush mount Top to Bottom
Wall mount bracket FE: 32 sounds W: Wall mount
100
for LKEH-FEW-EX
& LKEH-FVW-EX
■ Specifications
Rated Operating Recordable Sound Pressure Mounting
Model Voltage Range MP3, Melody Messages Mass
Voltage Temperature Duration (at 1m) Brackets
8ch bit input,
LKEH-FEF-EX Type-E Prerecorded Flush mount 32ch binary input 2.8Kg
EWH-24E-J-EX EXPLOSION-SAFE
CE II 3GD Ex nA IIC T4 Gc, Ex tc IIIC T85°C Dc IP65 94/9/EX(ATEX)CENELEC:EN 60079-0, EN 60079-15, EN 60079-31
EWH-24E-J-EX
166
100
Fuse Capacity
Power supply
wire 38 58 Model Rated Voltage Fuse
1A
3-φ9 EWH-24E-J-EX 12-24V
(Slow-blow)
Approx. 400mm from wire exit
25
80
25 25
Signal wires
125
Test Switch
The test switch can be used to check the operation or adjust sound volume Channel priority
(Located under the cover). 8 (Blue) > 7 (Green) > 6 (Orange) > 5 (Red) > 4 (Lightgreen) > 3 (Pink) > 2 (Yellow) > 1 (Skyblue)
The greater number has priority when any of the channels are activated simultaneously.
■ Specifications
Rated Power Operating Protection
Model Voltage Voltage Range Consumption Volume Outer Contact Capacity Temperature Range
Auxiliary Input Channel Rating
Mass
Max. -20°C~+60°C 8ch/1bit
EWH-24E 12/24V 8~28V AC
8W 105dB No more than 5A Humidity EWH: Non-voltage Contact or IP65 1.2kg
-J-EX AC/DC 9~35V DC
at 1m 85% or less. 32ch/binary
CLN-24-CD-PT-EX EXPLOSION-SAFE
CE II 3GD Ex nA IIC T4 Gc, Ex tc IIIC T135°C Dc IP65 94/9/EX(ATEX)CENELEC:EN 60079-0, EN 60079-15, EN 60079-31
CLN-24-CD-PT-EX
820lx
【lx】
800
■ Floor Mount ■ Wall Mount ■ Ceiling Mount
600
400
200
0
-800 -600 -400 -200 0 200 400 600 800
【mm】
High power LED with 820 lx provides sufficient ※ The pan/tilt brackets can also be removed for Rear Attachment applications.
illumination with only a 174mA current draw.
Color temperature of 6,500K is suitable for Natural light distribution when illuminating a
detailed and fine work, while providing wider work area with an equivalent to a 40W
photobiological safety. incandescent bulb with 550 lumens.
■ Specifications ■ Dimensions
Model CLN-24-CD-PT-EX
Color Code (Color) CD (Daylight)
Color Te mperature (typ.) 6500K □85
Lens
Illumination (typ.) (Centered at 24VDC) 1m 820 lx
To tal Luminous Flux (typ.) 550 lm
Body
Rated V oltage 24VDC (Polarized)
Operating V oltage Range 24V DC ±10%
102
AWG22×2 wires
Protection Rating IP66G/67G (JIS C 0920)/69K (DIN 40050 part 9) (excluding cable ends ) 3,000mm
Mounting Location/Direction Indoor / Any Direction
Insulation Resistance DC 500V 5MΩ or more
Pan-bracket Tilt-bracket
Withstand V oltage 500V AC for 1 minute (Between terminals and chassis) ※Rear-mount Hole
30Hz total amplitude 0.3m mp-p (2-M5, Pitch:16) (Unit:mm)
Vibration Resistanc e Back and forth, up and down, right and left for 2 hours each
To tal amplitude 0.3m mp-p (10-57Hz), Acceleration 19.6m/ s 2
Mass (T olerance ±10%) 430g
Attachment Pitch (2-M6, Pitch:26)
*1 : The typical value of LED brightness is 70% of the original specification, but may vary depending on actual applications.
*2 : IP66G and IP67G are Japanese Industrial Standards (JIS C0920-2003), and IP69K is the German DIN 40050 PART9 Standard.
*3 : CLN-24-CD-PT-EX Work Light can only be installed where risk of mechanical danger is limited to 2 Joules of impact energy
15
Zone 2, Zone 22
■ Dimensions
CLK-3C-24SG-□-EX 350 (13) 10.5
CLK-□□-24AG-□-EX
2S:250 3S/3C:350 6S:650
90 Mounting Pitch 5.2×7.2
5.2 50 12 Sliding Width
56
(15.5)
56
20.5 (1.5)
2:N/C 1:+IN
(12.5)
170
(2)
4.9
3:−IN 4:N/C 6
Name Plate
23
376 Pin Assignment Mounting
360 M12 Plug Surface Cable length:500mm
4-φ5.5 Name Plate
from wire exit
(0.7)
40
(13) 11.5
S type 9.3 C type
(15.5) 2:N/C 1:+IN
■ Specifications
4:N/C
(12.5)
Explosion-safe for gas and dust IP66, IP67 and IP69K rated
Suitable for Zone 2 and Zone 22 -40°C ∼ +60°C
CE compliance in accordance to ATEX Polycarbonate Mounting brackets available
100mm(140 lx), 200mm(270 lx), 300mm(400 lx), 600mm(650 lx)
900mm(810lx), 1200mm(890lx), 1500mm(945lx)
24VDC (polarized)
Cable Lengs: 3m CLA3S-24-CD-30-EX
Luminous Rated Operating Rated Current Center Radiation Main Body Operating Mounting Protection Vibration
Models Length Consumption Temperature Range Resistance Mass
Color Voltage Voltage Range (lx/50cm) Material Direction Rating
CLA1S-24-CD-EX Daylight
100mm 104mA 140 80g
CLA1S-24-CN-EX Natural White
CLA2S-24-CD-EX Daylight
200mm 208mA 270 130g
CLA2S-24-CN-EX Natural White
CLA3S-24-CD-EX Daylight
300mm 240mA 400 180g
CLA3S-24-CN-EX Natural White ー40℃ to +60℃
CLA6S-24-CD-EX Daylight DC 24V Body: Any Direction
600mm DC24V±10% 480mA 650 (RH 90% or less IP66/67/69K 19.6m/s2 340g
CLA6S-24-CN-EX Natural White (Polarized) Polycarbonate (Indoor Use)
No Condensation)
CLA9S-24-CD-EX Daylight 500g
900mm 720mA 810
CLA9S-24-CN-EX Natural White
CLA12S-24-CD-EX Daylight 960mA 660g
1,200mm 890
CLA12S-24-CN-EX Natural White
CLA15S-24-CD-EX Daylight 1,200mA
1,500mm 945 820g
CLA15S-24-CN-EX Natural White
16
RES-A Heavy Duty Revolving Warning Light for Harsh Environment
Robust Heavy Duty Revolving Warning Light
φ224mm diameter.
Integral Rotating Parabolic Reflector: For enhanced visibility from a distance.
Installation: Indoors—upright, inverted, sideways; Outdoors—upright only.
Main Body: Aluminum alloy die-cast with silver color baked finish.
Dome: Acrylic resin covered with clear hard-glass, and metal guard.
Available Colors: Red, Amber, Green and Blue.
IP66
The metal cable gland is an optional part. Needs to order separately.
The metal cable gland is only available as an option. Please order it separately.
RES-120A 115~120V AC
170 12V5W 12
RES-220A 200~220V AC
(80) 0.05A
RES-240A 230~240V AC
Bulb···G18 BA15S : Special Order
□130
□150 5
Mounting Dimension
Mounting Hole
4- ø9
130
130
(mm)
17
2 rue René Laennec 51500 Taissy France E-mail:[email protected]
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 Site web : www.hvssystem.com
RLR Robust Heavy Duty 11.2G LED Super Bright Beacons for Harsh Environment
162mm diameter
11.2G Anti-Vibration
IP66 Protection
Robust Heavy-duty Design
Dual LED with Twin Reflector
Maintenance-free with Brushless Motor
Strong Polycarbonate Housing
CE Compliant (12/24VDC)
Long Life
The RLR has many advantages
compared to a rotating beacon with
incandescent bulb and standard
motor. The LEDs last approximately
20 times to 40 times longer than an Vibration High High
incandescent bulb. The combination of the brushless Resistance Visibility Protection
motor and bearing mechanism allows the RLR to operate
from 8,000 hrs to 10,000 hrs, compared to 5,000 hrs for
other rotating beacons.
■ Dimensions
Structure of conventional motor Structure of Brushless motor φ162
Power Coil
supply Magnet Electric circuit Shaft
φ141
Shaft Power
Brush supply
Coil Magnet
Commutator
Brush Magnet Coil
193
■ Model Code
RLR-04-P-R
65
Color
26
RLR RLR-P
■ Specification Wire Entry Hole Wire Entry Hole
φ2
12
0°
φ2
12
°
0
0°
12
φ1
φ1
Mounting 40
Mounting 40 Hole
RLR-M1 12/24V DC 9.5~15V DC 2 -R (Red) Hole
110m/s (11G) -30˚C~+70˚C 1.0kg 3 –φ9
-Y (Amber) 3 –φ9
RLR-04 48V DC 20~30V DC
-G (Green) Name Plate
RLR-M2 90~250V AC 90~250V AC
2
45m/s (4.5G) -10˚C~+50˚C -B (Blue) 1.06kg Name Plate
mm
Headquarters
PATLITE (U.S.A.)
PATLITE (SINGAPORE)
To ensure correct use of these products, read the Instruction Manual prior to use.
Failure to follow all safeguards can result in fire, electric shock, or other accidents.
Specifications are subject to change without notice.
PATLITE (CHINA)
ISO9001:2008 Certified
ISO14001:2004 Certified PT. PATLITE INDONESIA PATLITE KOREA
Headquarters / Sanda Plant