ADD-DROP MULTIPLEXER
MULTIPLEXEUR ADD-DROP
à 155 MBIT/S COMPACT
ADR 155C
N56717020107
ADD-DROP MULTIPLEXER
ADR 155C
. The 19" subrack must be mounted only in racks with a bottom part that is
closed or fitted with a class V1 or HF1 or better air filter, or that stand on a
non-flammable floor.
. Handling precaution: For any work to be carried out inside the equipment, an
antistatic wrist strap must be worn.
1
Safety Extra Low Voltage Circuit
In ADR155C, battery replacement may only be done by return Supply Support Department.
1.1 - Generalities
The ADR 155C is an optical STM-1/STM-4 add-drop multiplexer used to build STM-1 point-to-
point links, STM-1 or STM-4 rings, or mesh networks with conduct (SNC) or STM-1 line (MSP)
protection, so performing the conveyance of links at 2 Mbit/s, 34 or 45 Mbit/s, Ethernet, STM-1.
Management network connections are performed via DCC D1 to D3 or D4 to D12 of the STM1
or STM-4, via VC12 of the STM1 or STM-4 or on Ethernet (ETH) or P interface (MNGT)
interfaces of the equipment.
§ S4.1, L4.1 or L4.2 STM4 optical card (ADR S4.1, ADR L4.1, ADR L4.2 cards) allowing a
VC4 connection or 3 VC3 connections or 63 VC12 connections or a combination of
VC3/VC12 connections
§ Ethernet 10/100, one port card (ADRLAN1 card), allowing 2 VC3 connections
§ Ethernet 10/100, one port card (ADRIMA card), allowing 8 VC12 connections
§ Ethernet 10/100, eight ports card (ADRGFP150 card), allowing up to 63 VC12 or 3 VC3
connections in 8 Virtually Concatenated Groups
§ G.703 34/45Mbit/s card (ADRE3DS3 card), allowing 1 VC3 connections
§ G.703 21 x 2 Mbit/s card (ADR21E120 / ADR21E1R8 card), allowing 21 VC12
connections.
For the connection of the different ports of cards, see § 1.3 - Connecting ports
A
V
M
C
Left uprights
of rack
ADR 155C
ADR 155C
ETSI rack
19" rack
76 76
,2 ,2
m m 2U
m m
2U
SYNC E1 OUTPUT
SYNC E1 OUTPUT
2 2
Two M6x12 Two M6x12
1 HM screw 1 HM screw
Two M6 Two M6
cage nuts cage nuts
19" rack mounting ETSI rack mouting
1.2.1 - Generalities
The ADR 155c subrack can be mounted in a 19" or ETSI rack. (voir Figure 1-1 - ADR 155C
Subrack Installation)
The ADR 155c package is provided with a mounting kit to adapt the subrack to a 19" or ETSI
rack.
This kit contains:
§ two brackets for adaptation to a 19" rack,
§ two brackets for adaptation to an ETSI rack,
§ 2 screws M3x4,
§ 2 flat washers M3
§ 8 screws CBLXS M3x6 to attach optional cards
The mounting kit for installation of the subrack on the uprights of the 19" or ETSI rack,
containing 4 cage nuts and 4 screws M6x12, is not supplied with the subrack.
The ADR155C has a system of thermal control by ventilation ; during the installation, provide for
sufficient space for the ventilation aperture on the left of the subrack, and also for the aeration,
at the top and right of the subrack. On the other hand, never hinder the natural air convection on
the right side.
Perform the following operations:
§ provide a 2U place in the rack for each equipment and a 1U space between equipments,
Deflectors are recommended to limit the temperature of the ambient air around the
equipment.
§ secure the attaching brackets for mounting in 19" rack, on either side of the subrack,
§ clip, on either side of the rack, two M6 cage nuts (item 1),
§ position the 19" subrack back in front of the rack,
§ slide the 19" subrack until attaching brackets are in contact with uprights, opposite the 4 cage
nuts, and then secure the subrack with 4 M6x12 hex head screws (item 2).
Installation of cards
RECALL: Prior to any operation on the cards, the operator must be provided with an
antistatic bracelet.
ADR 155C slots are non-dedicated. However, in order to make wiring easier and ensure the
homogeneity among sites, it is advisable to proceed as follows:
§ position the tributary cards from C clockwise
§ position the agregate cards from D counter-clockwise
§ check the ventilation module presence in its reserved slide,
§ the ADR 155c shelf is provided with the mothercard and FAN module already inserted
Secure each card through M3 screws of Torx type (6-branch star), using a suited screwdriver
§ FACOM reference AZX.10X75
§ Or STANLET reference 1-67-494
§ The ADD/DROP mode is the only one available (no terminal mode with line protection)
§ The B and D slots are, in this case, dedicated to STM-4 cards. In case of only one STM-4
card utilization, the second slot can however be used by another type of card.
Only one STM-1 channel can be extracted from the STM-4 flow, the three other one being in by-
pass ; the choice of this channel is selected by the menu "STM1 Selection" of the ADR STM-4
card.
§ Only one ADRGFP150 can be installed in a chassis either in the A slot or in the C slot.
§ When a ADRGFP150 card is installed and in use, the fan is automatically started up
All the connections, different from the 2Mbit/s connections of the 75 ohms strip, are performed
on the front panel of the shelf.
The cards can be extracted without intervening on the other cards or on their connections.
The connections to be performed on the equipment depend on the chosen configuration :
On the power supply strip:
§ poser supply ports: "PWR" or "PWRA" and/or "PWRB",
On the subrack motherboard strip:
§ Remote indication, remote control and station alarm port "LOOPS"
§ IP address configuration port "COMM" : allows the connection to a VT 100 emulation or
hyperterminal
§ Ethernet management port "ETH".
§ X24/V11 2Mbit/s traffic or management port "MNGT"
§ 2Mbit/s G.703 synchronization port "SYNC"
§ 21x2Mbit/s G.703 traffic ports "E1 INPUT / E1 OUTPUT".
On the STM-1 optical card :
§ 1 G.957 STM-1 optical port "TR / REC"
§ 2 engineering Order Wire ports "AUX" and "EOW"
On the STM-4 optical card :
§ 1 G.957 STM-4 optical port "TR / REC"
§ 2 engineering Order Wire ports "AUX" and "EOW"
On the STM-1 electrical card:
§ 1 G.703 STM-1 electrical port "TR / REC"
§ 2 engineering Order Wire ports "AUX" and "EOW"
On the ADR21E120/ADR21E1R8 card :
§ 1 G.703 21x2Mbit/s traffic port "E1 OUTPUT / E1 INPUT"
On the ADRE3DS3 card :
§ 1 G.703 34 ou 45 Mbit/s traffic port "TR / REC"
On the ADRLAN1 card :
§ 1 Ethernet traffic port "ETH"
On the ADRIMA card :
§ 1 Ethernet traffic port "ETH"
On the ADRGFP150 card :
§ 8 Ethernet traffic port "ETH"
Connection requirements :
ð For a right distribution of cords on either side of the subrack, the connections of slots A and
C, the 21 2Mbit/s accesses and synchronization access are oriented leftward. All other
connections are oriented rightward.
ð The run of cords must not hinder the extraction of a module; in particular, connecting cables
of the left subrack half is to be secured to the frame with enough backlash to enable the
ventilation module to be extracted during a maintenance operation.
Refer to the list of available cables in chapter 3 - Spare parts and Cables.
ð "PWR" and "PWRA" and/or "PWRB" Power supply ports can be connected simultaneously.
ð Always connect the equipment side before the energy source side.
ð The power block must be installed far from any heat source, and no traction must be
exercised on its connecting wires.
ð The used cable to connect the power block to the energy source must have a minimal
section of 1,5 mm² and be qualified <HAR> H03 VV_F ou <HAR> H03 VVH2_F.
ð The connecting land between the power block and the energy source must be respected.
ð The connecting electrical installation must be realized according to the present national
standard.
POWER
- 48V
2A MAX
"PWR" Jack type connector
9
5 2 - 48 B1 6 OB1
3 - Reserved 7 OB1
6
1 4 - 48 B2 8 OB2
5 - 48 B2 9 OB2
ADR-155C
Figure 1-2 – Connecting power supply ports
Input voltage : One or two Safety Extra Low Voltage (SELV) type – 48V sources
Voltage range allowed: - 36 V to - 60 V
Maximum voltage range : - 36 V to - 72 V
Power 100 VA maximum
Connector Male 9-way HE5
5 1
9 6
LOOPS
8 1
15 9
1 : Break B
2 : Make B 9 : Common B
3 : Common A 10 : Break A
4 : Gnd 11 : Make A
"SYNC" 5 : R-MON 4 N 12 : R-MON 4 P (OB)
6 : R-MON 3 N 13 : R-MON 3 P (OB)
5 1 7 : R-MON 2 N 14 : R-MON 2 P (OB)
9 6 8 : R-MON 1 N 15 : R-MON 1 P (OB)
1 : GND Schematic diagram
of a dry loop
2 : TX1_TIP 6 : TX1_RING
3 : RX1_TIP 7 : RX2_TIP
4 : RX2_RING 8 : RX1_RING MC B
5 : RESERVED 9 : RESERVED
Pin 8 Pin 1
"MNGT"
5 1 1 : TX_ETH_TIP 5 : NC
2 : TX_ETH_RING 6 : RX_ETH_RING
9 6 3 : RX_ETH_TIP 7 : NC
COMM 4 : NC * 8 : NC
1 : GND
5 1
2 : RXPA 6 : RXPB Right LED : link status
9 6 ON : correct link
3 : TXPA 7 : TXPB
4 : TXCLKPA 8 : TXCLKPB 1 : DCD Left LED : traffic status
2 : RX 6 : DSR : on transmission
5 : RXCLKPA 9 : RXCLKPB ON
3 : TX 7 : RTS
4 : DTR 8 : CTS NC * : Reserved
5 : Gnd 9 : NC *
"LOOPS" Interface:
Ports 4 remote indication inputs for floating contacts (Local user inputs),
biased to -48 V internally, active when closed and with electrical
isolation (loop current = from 1 to 10 mA),
2 dry loop outputs (common, normally closed and normally open)
(Local user outputs) for station alarm or remote control use
(maximum current = 100 mA on resistive load). The common point
of each loop is internally connected to OB.
Connector Female 15-way HE5
8 1
15 9
"COMM" Interface:
5 1
9 6
Wiring diagram
1 1
6 6
9
5 9
5
"ETH" Interface:
Pin 8 Pin 1
Front view
TXCLKP (B-A)
(codirectional transmit
clock output)
TXP (B-A)
(output for data transmitted B8 B1 B2
over P interface)
RXCLKP (B-A)
(receive clock input)
RXP (B-A)
(input for data received B8 B1 B2
over the P interface)
"SYNC" Interface
Ports Two G.703 2MHz external synchronization inputs (T3) and one
G.703 2MHz clock output (T4) compliant with ITU-T G.703
Recommendation (§ 13.3 for input port, § 13.2 for output port)
Impedance 120 Ω balanced,
Connector Female 9-way HE5 (120 Ω).
5 1
9 6
Pin N° Signal name Comments
1 GND Ground
6 TX1 RING (T4-) Output T4-1 (cold point)
2 TX1 TIP (T4+) Output T4-1 (hot point)
7 RX2 TIP (T3+) Input T3-2 (hot point)
3 RX1 TIP (T3+) Input T3-1 (hot point)
8 RX1 RING (T3-) Input T3-1 (cold point)
4 RX2 RING (T3-) Input T3-2 (cold point)
9 NC Reserved
5 NC Reserved
NOTA : The shielding of the connector case is connected to the subrack front panel ground
This interface uses two connectors : E1 INPUT connector for inputs (named RX) and
E1 OUTPUT connector for outputs (named TX)
15 1
30 16
44 31
NOTA : The shielding of the connector case is connected to the subrack front panel ground
ADR IC1.1
LED STATUS 8 1
15 9
Green Red
NC: Reserved
Figure 1-4 - Connecting ADR IC1.1 and ADR IC1.2 ADR Optical cards inputs
(FC/PC Connector)
LED STATUS
8 1
Green Red
15 9
ON OFF Card in service
ON ON Card in alarm 1 : NC
OFF OFF Hardware default (fuse) 2 : TA 9 : TB
OFF ON Card out of service 3 : TOF PA 10 : TOF PB
Flashing Autotest default 4 : RA 11 : RB
5 : ROF PA 12 : ROF PB
6 : R64 A 13 : R64 B
7 : T64 A 14 : T64 B
8 : GND 15 : NC
Figure 1-5 - Connecting ADR S1.1, ADR L1.1, ADR MM1, ADR S4.1, ADR L4.1 and ADR L4.2 ADR
Optical cards inputs
(SC/PC Connector)
10 TOFPB (+) Transmit mode byte sync output indicating the positioning of bit 1
3 TOFPA (-) and sent on the rising edge of clock T64 (B-A)
11 RB (+) Output for data extracted from SDH line and sampled on the falling
4 RA (-) edge of clock T64 (B-A)
12 ROFPB (+) Receive mode byte sync output indicating the setting of bit 1 and
5 ROFPA (-) sent on the falling edge of clock T64 (B-A)
Timing diagram for the "EOW/AUX" interface in contra-directional mode (64 kbit/s synchronous
use):
T64 (B-A)
(transmit clock output)
T (B-A) B8 B1 B2
(input for data to transmit
over STM1/STM4 line)
TOFP (B-A)
(transmit synchro byte
pulse output)
R64 (B-A)
(receive clock output)
R (B-A)
(output for data received B8 B1 B2
from STM1/STM4 line)
ROFP (B-A)
(receive synchro byte
pulse output)
As EOW and AUX ports are physically integral with ADR Optical, operating the order wire and
auxiliary channels with MSP protection requires the use of a "Y" cord electrically connecting, one
by one, identically, the signals of EOW and AUX connectors.
Likewise, in order to ensure a good behavior during the changeover from one module to the
other, the operator should take care to keep identical configurations on both ADR Optical cards ;
in case of modification, automatic recopy is done and a warning message appears.
Only the connections are not identical. There must be no connections on the "Protection"
module, as in all the connections are made to the "Working" module.
More over, the management links (PPP over DCC) must be created on the « Working » module
and not on the « Protect » module.
Cables' Codification
See paragraph 3 "Spare parts and Cables"
ADR ERE
LED STATUS 8 1
Green Red 15 9
NC: Reserved
Figure 1-6 - Connecting ADR ERE card inputs
ADR LAN1
LED STATUS
HALF/FULL
Green Red
Yellow LED : Ethernet interface type
ON OFF Card in service (Half or Full Duplex)
ON ON Card in alarm
OFF OFF Hardware default ON : Full duplex
OFF ON Card out of service
Flashing Autotest default
10/100
ON : 100 Mbit/s
ADRIMA
STATUS TX LNK
ETH
LED STATUS
Green Red
1 8
STATUS ETH
LED STATUS
Green Red
ON OFF Card in service
ON ON Card in alarn
OFF OFF Hardware default (fuse)
OFF ON Card out of service
blinking Autotest default
"ETH" Interface :
Pin 8 Pin 1
Front view
ADRLAN and ADRIMA cards have a « direct » Ethernet interface. The ADRGFP150 have a direct or a cross Ethernet
interface depending on the configuration.
ADR E3DS3
STATUS DS3 E3
TR REC 45 34
2 Mbit/s traffic connections, performed on "E1 INPUT" and "E1 OUTPUT" ports on the
ADR21E120/ADR21E1R8 card are identical with those performed on "E1 INPUT" and
"E1 OUTPUT" ports on the front side of the motherboard (see § 1.3.2.5)
ADR 21E120
LED STATUS
"E1 OUTPUT" and "E1 INPUT"
Green Red
15 1
30 16
ON OFF Card in service 44 31
ON ON Card in alarm
OFF OFF Hardware default (fuse)
OFF ON Card out of service
Flashing Autotest default
Connector's characteristics
(identical Motherboard)
The 75 Ω connecting strip is supplied with brackets attaching, reversible for installation in 19" or
ETSI bay.
§ Secure connecting strip on the rack uprights, above or under the ADR 155C shelf,
§ Plug in respectively 'E1 INPUT', 'E1 OUTPUT' and 'SYNC' connectors on the connectors
(120 Ω) with the same name in the ADR 155C shelf,
§ Make 75 Ω connections:
§ (TX) 1 to 21 transmission port : connecting strip upper line,
§ (RX) 1 to 21 reception port : connecting strip lower line,
§ SYNC (TX and RX) port : two connectors on the right side of the connecting strip.
The « Synchro input » access of the 75 Ω connecting strip correcponds to the T3-2 interface of
ADR155c.
The 75 Ω connecting strip is supplied with brackets attaching, reversible for installation in 19" or
ETSI bay.
The 75 Ω connecting strip is supplied with brackets attaching, reversible for installation in 19" or
ETSI bay.
The 75 Ω connecting strip is supplied with brackets attaching, reversible for installation in 19" or
ETSI bay.
REAR PANEL
FRONT PANEL
LOCAL TEST
Equipment Inventory
- 48 V redundancy Check
* case of underequipped
Local transmission test (30 mn) *
unitary equipment
Optical connection
Configuration Elaboration
yes
Link established
Optical measurements
Counters reset
24 H link Performance
Equipment operational
(constitution of installation file)
Configuration Save
1.4 - Commissioning
This paragraph describes the Equipment's commissioning at general way. For more details, see
the chapter 5 "Startup Guide".
The equipment can be operated from a PC fitted with VT100 emulation and HTTP navigator; its
minimum configuration is defined in the paragraph 5.2 of "Startup Guide"
A local terminal with VT100 emulation is indispensable during the first commissioning, in order
to be able to access the equipment via the management function; however, this terminal only
enables the communication function to be parameterized (definition of the equipment IP
address).
Procedure.
F On the first commissioning, the equipment scans its constitution and considers it as the
expected configuration, in service, monitored. It is thus advisable to insert the traffic cards
before power-up, in order to speed up the commissioning.
F Switch on the power supply connected to the equipment.
F The equipment conducts self-tests:
§ When self-tests have run correctly, the "ON" indicator is lit,
§ In the opposite case, an indicator flashing code defines the faulty self-test (contact the
hotline).
F Parameterize the communication interface, using the VT100 (see § 1.4.2).
F Using the HTTP navigator, (see § 1.4.3).
§ Update the equipment time and date
§ Configure the remote management ports using the Web Browser
F Connect the 2 Mbit/s, 34/45 Mbit/s, Ethernet, STM-1, STM-4 and SYNC ports, according to
the required equipment composition,
F Connect the AUX and EOW ports required.
F Download a predefined configuration or prepare the desired configuration, using the HTTP
navigator:
§ Create the connections
§ Establish the wished protection (MSP protection, SNC protection ...)
§ Choose the synchronization source, and change its parameters if required.
§ Change, if necessary, the monitoring parameters and the alarms configuration.
The default configuration of the various parameters is provided by § 2.3.
F Conduct the tests on STM-n links, complying with the process described in Figure 1-13
F From that moment, the equipment is operational.
F Operating alarms can signal a wrong connection of interfaces. Check the connection of
ports, the alarms corresponding to the connected ports, and correct any problems that may
arise.
F Save configuration.
REMARK: It is possible, once the commissioning is performed, to connect additional 2 Mbit/s G.703,
E3/DS3, Ethernet,STM1 or STM-4 ports, and to insert or extract powered cards.
IONOS
D1 - D 3
D1 - D 3
STMn
STMn
on West
on East
D 1 - D 3 STMn
HTTP on East
E P
ADR T
H
R P
P
D 1 - D 3 STMn
S NMP on West
IONOS is necessary
to operate this FOT C D1 - D 3 D1 - D 3 D1 - D 3
(but the ADR can be on STMn STMn STMn
operated from the ETH tributary on East on West
interface of the FOT C
PP P
FOT C * S H
D1 - D 3
N T
on STMn
aggregate M R T ADR
E P P P
T
H
R P
P
ETH
SNMP
Figure 1-14 presents the available resources and various configurations possible for the
communication function :
1. Connect the "COMM" access to a free "COM" port on the PC with VT100 emulation.
2. Switch on the PC.
3. If it is the first time you run the "Hyperterminal"application on this PC :
§ successively select, in the Windows desktop, the Start, Programs, Accessories and
Hyper terminal buttons,
§ select the icon representing the "Hyperterminal"application: a description window for
the application is displayed.
§ enter a name and choose an icon for the connection, then validate your choices: a new
window is displayed.
§ select the "COM" port on the PC which is connected to the equipment then validate your
choice. A new window is displayed:
§ configure the port parameters as indicated below:
§ Bits per second : 19200
§ Data bits :8
§ Parity : none
§ Stop bits :1
§ Flow control : none
§ validate the configuration.
§ save the connection ("Save" command in application File menu).
§ NOTE : The next time you want to open the "Hyperterminal" application, you will
simply need to choose the connection icon to connect to the equipment. Once the
equipment is powered up, the operation menu is displayed.
§ to exit the "Hyperterminal" application, select Exit in the File menu.
4. Open a session and enter your password (to configure the communication function, you
need to have "supervisor" rights)
NOTE : by default, for the initial commissioning procedure, the password is empty.
To select a command, type the command number in the "Choice ?" text area and press the
"ENTER" key to validate your choice.
The above screen presents an Ethernet communication interface with its characteristics:
"Interface State" : choice of interface state: 0 (Interface off) or 1 (Interface on).
"IP Address" : IP address.
"Subnet mask" : sub-network mask.
"Route Protocol" : protocol: 0 (None), 1 (RIP) or 2 (OSPF)
This command is used to immediately reboot the application and restart with the parameters
already stored in the equipment.
This REBOOT is performed with no impact on the traffic.
Once the parameter definition process is completed, this command closes the current session.
An automatic session exit is performed after a few minutes if no activity is detected (this time
period can be configured using the manager).
The screen displays the management routes already defined with their characteristics:
Ø Hops : hop 1, 2, 3…Path used to go from one machine to another.
1 2 3
Ø Unit. size : Maximum size of IP packet which can reach the remote equipment.
IE 5.0 configuration
NOTE: It is preferable not to have a cache with the IE 5.0; otherwise, you are never sure to have
updated data when the screen opens.
1. In the Internet Explorer Tools menu, click Internet options.
2. In the General tab, click Parameters.
3. Tick the radio button: On each page visit, then define the disk space to be used for
1 Mbyte. Click [OK].
4. In the Temporary Internet files tab, click Delete Files.
5. Tick Delete all offline content, then click [OK].
6. In the Internet options dialog box, click [OK], then close the IE browser to allow the
options to be acknowledged.
Remark
After an upgrade of the application code, the cache must be cleared as following :
In the Internet Explorer "Tools" menu click "Internet Options / General tab / Temporary Internet
files tab / Delete Files".
PC Configuration
To get a correct date for the equipment HTTP, the environment variable "TZ" must not be
defined. To list all environment variables, type "Set" in the MS DOS console.
To get a correct display of HTML pages, fonts must not be defined as "large" in display
properties of the configuration panel.
The PC is connected via Ethernet (the PC's gateway must be in the same subnetwork as the
Ethernet interface of the ADR).
§ On the Welcome screen, fill in the "Address" field with the IP address of the ADR 155C
equipment.
§ If a screen with a 860 x 600 resolution is used, reduce character to obtain correct pages
display (for example, 'synchronization' page must display 3' 'Apply' buttoms.
§ On the first commissioning, the password is empty; click on Apply to access " Shelf View"
screen.
On session opening on the HTTP navigator, the " Shelf View" screen represents the equipment
global view, where each slot is marked with a letter, A, B, C, D or M for mothercard, according to
the following screen.
§ frame of module is red in the case of insertion alarm (Missing, Mismatch detective)
§ elements inside in-alarm modules are framed red in the case of a major alarm, yellow for a
minor alarm,
§ modules configured out of monitoring are represented greyed,
§ present modules configured out of service include a red cross to signal this administrative
status,
§ Absent modules configured out of service appear as all blank panel.
§ activate the common functions of the equipment, (such as the synchronization, safety, traffic
information, …etc.) by clicking on a function in the menu bar located above the equipment
view. This opens a sub-menu; see tree structure of the general menu Figure 1-16 – Menu
structure.
§ access the functionalities related to a module in particular (for example, MSP protection in
the case of an ADR Optical module) : click on the module to be selected, the selection arrow
is blinking and its specific menu appears; see tree structure of "card" menus Figure 1-16 –
Menu structure
§ view the own characteristics of a port (connections performed, configuration of connections,
alarm states ...), by selecting the relevant connector.
For each function viewed, the configuration parameters, operating commands, active
parameters and alarm states are grouped together on the same screen, with the various actions
possible being accessible or not by the operator according to his/her clearance level.
The upper edge of the navigator window recalls the equipment name, its IP address, the
clearance level acquired and, if required, the slot concerned.
LOGIN
Menu "ADR21E120" Menu " ADR STM-1 Optique" Menu "ADR STM-4" Menu "Carte mère"
ou Menu "ADRERE"
Maintenance
Maintenance Maintenance
Monitoring Maintenance
Monitoring Monitoring
Service Monitoring
Service Performance :
Expected Card Service VC12 Near (# 1 to 21)
Expected Card
Performance : Expected Card VC12 Far (# 1 to 21)
Performance :
VC12 Near (#1 to 21) Performance : Board status
VC12 Near / VC12 Far #
VC12 Far (# 1 to 21) VC12 Near / VC12 Far # VC3 Near / VC3 Far # 2M Ports
Board status VC3 Near / VC3 Far # VC4 Near / VC4 Far #
VC4 Near / VC4 Far MNGT Port
2M Ports MST Near / MST Far /
MST Near / MST Far / IP Parameters
RST Near
RST Near Loops
Board status
Board status
Menu "ADR21E1R8" EOW
EOW
AUX
AUX
STM4's Functional Menu "ADRIMA"
STM's Functional Groups Groups
Maintenance
Protection STM1 Selection
Monitoring
Service Monitoring
Expected Card Service
Performance : Expected Card
VC12 Near (#1 to 21) Board status
VC12 Far (# 1 to 21)
IMA Ethernet
Board status
IMA's Functional Groups
Retiming
2M Ports Menu "ADRE3DS3" Menu "ADRLAN1"
Menu "ADRGFP"
Menu "ADRFAN"
Expected card
2. OPERATION
2.1 - Functional description
The ADR 155C is an optical STM-1/STM-4 add-drop multiplexer used to build STM-1 point-to-
point links, STM-1 or STM-4 rings, or mesh networks, so achieving the conveyance of links PDH
(at 2 Mbit/s, 34 or 45 Mbit/s, Ethernet or STM1).
The ADR 155C can also be connected to an equipment of the synchronous digital hierarchy in
accordance with UIT-T recommendations G.707 and G.783.
The ADR 155C modelling in functional blocks is presented below:
2.2 - Generalities
The ADR155C operation and maintenance are carried out:
- either directly on the equipment, through the front panel indicator lights and two engineering
management loops (loops A and B),
- or from a PC fitted with Web Browser,
- or from a network manager, using the SNMP protocol for the network and supervision
aspects, and the included Web Browser
Configuration parameters
NOTE :
1) The functional blocks naming, configuration parameters and their default value, noted
"XXXXXX", are displayed on Web Browser.
2) The default values are indicated when a connection is created.
"Sf/Sd priority"
SF/SD priority according to Recommendation G.783 [1994] annex A.1.2.1 "Low"
possible value :"high" or "low" (compatibility with MXA)
"Default Edge"
ADRE3DS3 Card
"E3 (34M)" or "DS3 (45M)"
34 or 45 Mbit/s physical interface selection "E3 (34M)"
Connecting cable length selection so that transmitted pulse complies to
template defined in Bellcore GR-489-CORE standard : "Type of cable"
(DS3/45Mbit/s mode only "short"
"long" or "short" (length < 225 ft or 70m)
Table 2-9 – Configuration parameters (8/13)
Synchronization
The synchronisation of the local equipment and remote equipment is managed according to the
available synchronization sources, their quality and the priority they are allocated.
The synchronization sources possible are:
§ standalone operation (local oscillator),
§ T1 extracted from one of the incoming STM-n streams (1 to 4 possibilities according to the
number of ADR Optical cards present in the equipment),
§ T2 : one 2 Mbit/s G.703 source per declared 2 Mbit/s module, and selected from the various
2 Mbit/s G.703 accesses
§ T3 : two external 2 MHz G.703 sources
The following figures give typical synchronization examples according to equipment connections.
2 MHz external
sync input (T3):
- Quality = PRC,
- Priority = 1.
STM-n port (T1-C): STM-n port (T1-C):
- Quality = DNU - Quality = DNU
- Priority = 2. - Priority = 2.
ADR155C 1 ADR155C 2
ADR155C 3 Synchronization
of other equipments
SSM = PRC
T0 = T1-c
Synchronization
of other equipments
Figure 2-1 - Synchronization from the 2 MHz external sync input (T3)
ADR155C 3 Synchronization
of other equipments
SSM = SEC
T0 = T1-c
Synchronization
of other equipments
NOTE : Synchronization is applied to the 2 Mbit/s port of the ADR155C which is enabled first
(local ADR155C in the example).
Loops Management
On remote sites, two local outgoing loops (Local user outputs A and B) are activated on the
appearance of a local equipment alarm or remote indication loops 3 and 4 (Local user input #3
or #4).
The remote loopback function allows an equipment named "central site", to register faults
present on remote sites.
This function requires each site to transmit to the central site an alarm presence message. This
messages which corresponds to remote monitoring loopback 1 or 2 (Local user input #1 or #2)
is transmitted in the S1 byte. To link this message to equipment's alarms, the outputs of the A
and B loops (Local user outputs A and B) should be connected to remote monitoring loops 1 and
2 (Local user input #1 or #2) respectively.
Data chaining in a bus or ring type network architecture is provided by "OR" function validation
between the data received (Far user inputs #1 et #2) via S1 STM-n West and S1 STM-n East,
and local data, for each site in the network.
At the "central site" equipment, "OR" function validation between the data received (Far user
inputs #1 and #2) via S1 STM-n West and S1 STM-n East, and local data (Local user input #1 or
#2 and local alarm), enables local alarm loopbacks to be activated (Local user outputs A and B).
To configure the remote loopback function, the following parameters should be programmed :
"Line remote loopback" and " central site". The Figure 2-3 gives an example of remote
management of the local outgoing loops according to the equipment connections.
ð Pushbuttons :
Designation Location Role Action initiated
"ACK" Motherboard Alarm Pressing disables the outgoing alarm
acknowledge loops. The visual alarm is kept.
"INIT Motherboard Configuration "Factory" Configuration reload
CONFIG"* reload
* To activate "INIT", keep button pressed for at least 5 seconds. This button is
inaccessible (and unused) in normal operation. It is necessary to remove the cover to
access it.
Correlation of faults
A correlation mechanism is implemented on all faults detected.
This correlation mechanism, implemented on each change of information collected, is used to
eliminate faults induced by other faults to facilitate fault finding and fault locating.
The following tables define the faults that are masked for each fault detected in the system..
Key :
: The fault concerned on the current line is masked by the fault in the current
X
column.
For example: The LOF fault is masked by fault 2 (LOS).
FAULTS 1 2 3 4 5 6
FAULTS TF LOS LOF AIS SD-B2 RDI
1 TF
2 LOS
3 LOF X
4 AIS (MS-AIS) X X
5 SD-B2 X X X
6 RDI (MS-RDI) X X X
FAULTS 1 2 3
FAULTS PAM SCM OTM
1 PAM
2 SCM X
3 OTM X
Correlation of AU faults
The AU faults are masked by the STM-n LOS, LOF and AIS (MS-AIS) faults.
The TU-LOM fault is filtered, if there is no configured VC12 connection on this STM-n.
FAULTS 1 2 3 4 5 6 7 8
FAULTS AU-AIS AU-LOP UNEQ RDI SLM TU-LOM TIM SD-B3
1 AU-AIS
2 AU-LOP
3 UNEQ (VC4 UNEQ) X X
4 RDI (VC4 RDI) X X X X
5 SLM X X X X
6 TU-LOM X X X X X
7 TIM X X X
8 SD-B3 (VC4) X X X
FAULTS 1 2 3 4 5 6
FAULTS TU-AIS TU-LOP LP-UNEQ LP-RDI LP-SLM LP-SD
1 TU-AIS
2 TU-LOP
3 LP-UNEQ X X
4 LP-RDI X X X
5 LP-SLM X X X
6 LP-SD X X
FAULTS 1 2
FAULTS LOS AIS
1 LOS
2 AIS X
The result of these calculations is then aggregated for each of the monitoring points in:
§ 24-hour counters (BBE, ES, SES and UAS),
§ 15-minute counters (BBE, ES, SES and UAS).
The last 6 UNAVAILABLE PERIODS are stored and displayed on Web Browser.
The performance process is initialized when the equipment is powered up and the monitoring
point is monitored.
The last 16 non-zero 15-minute counters, the current 15-minute counter, the last non-zero 24-
hour counter, the current 24-hour counter and the last 6 unavailable periods are displayed on
Web Browser.
Replacing a card
Remarks:
§ Alarms appear whenever a card is extracted from the subrack. In order to prevent feedback
of M/m alarms and ALA 1 and ALA 2 loops, the card should be declared out of service.
§ Each module can be extracted or inserted without acting on other modules or their wiring.
Only the traffic of the concerned module is disturbed.
Procedure:
The procedure described below can apply, unless otherwise specified, to all the cards in the
equipment.
1. Put the card concerned "no service" from Web Browser.
2. Remove the external connections performed on the card front side.
NOTE: When the external optical fibers are disconnected, reinstall the protective
covers on connectors.
3. Screw off the TORX screws located on the front side, using the suited screwdriver and
unplug the card
4. Extract the card, complying with the measures of protection against electrostatic discharges.
NOTE: For any card handling, the operator must wear an anti-static bracelet well
tight around the wrist and earthed.
5. Package the extracted card in an anti-static bag.
6. Take the new card out of its anti-static bag.
7. Carefully insert the card into its cell, complying with the measures of protection against
electrostatic discharges, and secure it with the TORX screws.
8. Restore connections on the card front side.
NOTE: For the optical STM-n card, remove the protective covers from connectors.
To clean the optical connectors, use a pressurized air aerosol.
9. Configure the card, if necessary, and put it into service.
The ADRFAN module consists of two redundant fans in order to ensure sufficient ventilation
when either of them is defective. Fan failures are detected on the motherboard by monitoring the
power consumed; failures are viewed on " Shelf View" screen of Web Browser.
Default parameters lead to the following behaviour :
§ if ADRFAN module is framed yellow, one of two fans is faulty (minor alarm),
§ if ADRFAN module is framed red, both fans are faulty (major alarm).
NOTE: The operation of ADRFAN is not continuous; its initiation is related to the
equipment internal temperature and to the operating mode selection.
ADRFAN can be extracted, it can be replaced at any moment without disturbing the traffic.
Procedure:
1. Screw off the TORX screws located on the front side, using the suited screwdriver and
unplug the card.
2. Extract the card, complying with the measures of protection against electrostatic discharges.
NOTE: For any card handling, the operator must wear an anti-static bracelet well
tight around the wrist and earthed.
3. Package the extracted module in an anti-static bag.
4. Take the new module out of its anti-static bag.
5 Carefully insert the module into its place, complying with the measures of protection against
electrostatic discharges, and secure it with TORX screws
Procedure:
1. Disconnect the power cable or the 100-240//48V 60W/ transformer from the primary power
source.
2. Screw off the fuse-holder from the power supply front panel.
3. Replace the defective fuse with an equivalent fuse, namely:
4A quick-break fuse (HA214A)
Dimensions length: 20mm ± 0.5
diameter: 5.2 mm +0.1/-0.2
4. Screw the fuse-holder.
5. Reconnect the power cable or the 100-240//48V 60W/ transformer to the primary power
source
ADR 155c
ADR 155c A155 BLK STM1/4 21E1 19"/ETSI CORE 251 119 665
ADR FAN FAN MODULE 251 131 182
A155 BNC/75 21E1 ETSI 1U3 19" ADAPT 251 035 468
CARDS
ADR IC1.1 A155 BLK FC/PC IC1.1 OPTIC STM1 CARD 251 137 366
ADR IC1.2 A155 BLK FC/PC IC1.2 OPTIC STM1 CARD 251 137 379
ADR MM1 A155 BLK SC/PC MM1 OPTIC STM1 ITFE 251 050 639
CARD
ADR S1.1 A155 BLK SC/PC S1.1 OPTIC STM1 ITFE CARD 251 137 387
ADR L1.1 A155 BLK SC/PC L1.1 OPTIC STM1 ITFE CARD 251 137 390
ADR S4.1 A155 BLK SC/PC S4.1 OPTIC STM4 ITFE CARD 251 128 619
ADR L4.1 A155 BLK SC/PC L4.1 OPTIC STM4 ITFE CARD 251 128 627
ADR L4.2 A155 BLK SC/PC L4.2 OPTIC STM4 ITFE CARD 251 172 592
ADR ERE A155 BLK BNC ELEC STM1 ITFE CARD 251 137 431
ADRE3DS3 A155 BLK BNC E3DS3 ITFE CARD 251 137 423
ADR21E120 A155 BLK BNC 21E1/120 ITFE CARD 251 137 402
ADRLAN1 A155 BLK ADRLAN 10/100BT ETH ITFE CARD 251 137 410
ADR21E1R8 A155 BLK BNC 21E1/8E1 RET ITFE CARD 251 259 985
ADRIMA A155 BLK 10/100BT ADRIMA ETH ITFE CARD 215 229 007
ADRGFP150 A155 BLK 10/100BT ADRGFP ETH ITFE CARD 215 347 772
External
transformer
MNGT port
Management interface cable between two ADR 3m 55 670 656
155C
9 points to 15 points adaptation cable for X24/V11 2.5 m 251 025 855
5m 251 025 876
COMM port
VT100 Management port 1,8 m 4 980 214
ETH port
Ethernet port on mother board or
ADRLAN1, ADRIMA, ADRGFP150 cards : cable
UTP category 5
3m 55 670 422
Right cable male – male * 3m 55 670 610
Crossover cable male – male **
LOOPS port
Remote indication, remote control and station alarm 2,5 m 6 013 628
loops (1/2 cable) 12 m 6 013 161
POWER port Power supply
Free extremity cable 3m 251 065 817
PAPA cable 3m 55 670 797
TR or REC ports (ADR IC1.1, IC1.2 cards) 2.5 m 6 491 366
3.4 m 6 491 367
FC-PC/FC-PC optical Jumper 5.8 m 6 491 369
7m 6 491 370
8.2 m 6 491 371
9.4 m 6 491 372
15 m 55 670 481
20 m 55 670 495
25 m 55 670 752
4. SPECIFICATIONS
EQUIPMENT
Optical specifications
Interface type IC1.1 = L1.1 + S1.1 or IC1.2 = L1.2 + S1.2
or MM1 or S1.1 or L1.1 or S4.1 or L4.1 or L4.2
Bit rate STM-1 : 155.520 Mbit/s ± 20 ppm
STM-4 : 622.08 Mbit/s ± 20 ppm
Standard ITU-T G.957 for single mode interface
ANSI T1.646 (MM1) for multi-mode interface
Encoding Not encoded (NRZ)
Optical fiber Single mode : 1310 nm (IC1.1, S1.1, L1.1, S4.1, L4.1)
or 1550 nm (IC1.2, L4.2),
or multi-mode : 1310 nm (MM1)
UIT-T G.652.
Guaranteed attenuation IC1.1, IC1.2 : 0 – 28 dB with no external attenuator
L1.1 : 10 – 28 dB
S1.1 : 0 – 12 dB
MM1 : 0 – 4 dB
L4.1, L4.2 : 10 – 24dB
S4.1 : 0 – 12dB
Typical range S1.1 : 0 – 15 km
IC1.1 : 0 – 40 km
L1.1 : 10 – 40 km
IC1.2 : 0 – 80 km
MM1 : 0 – 2 km
S4.1 : 0 – 15km
L4.1 : 10 – 40km
L4.2 : 10 – 80km
Connector IC1.1, IC1.2 : FC/PC ou SC/PC
L1.1, S1.1, MM1, S4.1, L4.1, L4.2 : SC/PC
Mechanical specifications of ADR 155c subrack
Height 2U
Width 19" or ETSI
Depth 257 mm rack 19''
243 mm rack ETSI
Weight 6 kg approx.
Protection Class (IP) Corresponding to the IP of the rack used
Mechanical specifications of 75Ω strip
Height 1.3U
Width 19" ou ETSI
Depth 75mm
Consumption < 40 W (for an equipped subrack of two ADR Optical
cards and two ADR LAN cards)
(see details below)
EQUIPMENT
Environmental specifications
Mechanical ETS 300 119-4 (19") or CEI 297-3 (ETSI)
ETS 300 019-2-3
Climatic conditions CEI 721-1 (1993)
ETS300 019 part 1-3, class 3.1, 3.2
Operating temperature range - 5 °C à + 45°C
Extended operating temperature range - 5 °C to + 55°C (the MTBF [Mean Time Between
Failure] is significantly degraded)
Packaged transportation and storage - 40°C to + 70°C
temperature
Relative humidity < 85%
EMC (Electromagnetic Compatibility)
EN 300386
And ESD
Safety NF EN 60950 -1 April 2002
(the equipment does not provide the fire envelope)
Energy ETS 300132-2
(is VLV equipment)
(*)
Predicted reliability
-6
Motherboard 1,12 10
-6
ADR 21E120 card 0,29 10
-6
ADR21E1R8 0,43 10
-6
ADR1 IC1.1 card (FC/PC) 1,5 10
-6
ADR1 IC1.2 card (FC/PC) 1,5 10
-6
ADR MM1 card 0,96 0
-6
ADR L1.1 card 0,96 0
-6
ADR S1.1 card 0,96 0
-6
ADR ERE card 0,29 10
-6
ADR E3DS3 card 0,21 10
-6
ADRLAN card 0,52 10
-6
ADRIMA card 0,54 10
-6
ADRGFP150 card 0,77 10
-6
ADRS4.1 card 1,1 10
-6
ADRL4.1 card 1,1 10
-6
ADRL4.2 card 1,1 10
-6
Background 0,25 10
-6
Power supply 0,39 10
-6
ADR FAN Module 3 10
Table 4-2 - ADR 155c technical characteristics (2/4)
(*) The predicted reliability computations have been realized with the RAM COMMANDER
software issue 7.2 according to the UTE C80 810 of july 2000 standard, on the assumption
of specific requirements for the following: ambient temperature 20°C (with ventilation
conditions such as the subrack internal middle temperature is less than 40°C), environment
(mounted on the ground, fixed and protected), qualification, and component ageing (year of
components production : 2003).
Any changes in the above requirements may entail variations in the results.
* These power consumptions are typical values and may be used for dissipation evaluation. It
is necessary to add 20% to estimate peak values which determine power rack capacity. This
allows to take into account the dynamic power variations and the converter efficiency
variations according to total power supply.
Warning : It is necessary to add another 10% when powered by 72V supply.
5. STARTUP GUIDE
Introduction
Thank you for acquiring the ADR155c equipment.
The start up procedure is supplied with the equipment to help you, using examples, to configure it in accordance with the topology of the network to
be build.
PC minimum requirements
Memory 32 MB 64 MB 128 MB
Softwares
Web Browser : Internet Explorer1 5.0 (*)
(*) The operating PC can be equipped with Internet Explorer 5.5 or 6.0 (Windows XP delivered issue)
1
Trademark of Microsoft Corporation
In order to be managed, the ADR155c subrack must have the Equipment address and the Ethernet port address configured in two different sub-
networks.
The Equipment and Ethernet port addresses are configured using the Windows HyperTerminal application.
Ø Connect the equipment's "COMM" port to an unused "COM" port of the PC using the 9pts Male / Female SUB-D straight cable
Ø Power up the PC
Ø Start Windows and run the HyperTerminal application
(Menus: Start/Programs/Accessories/HyperTerminal)
Ø Give a name and select an icon for the connection then apply the choices
Ø Select the PC's "COM" port that is connected to the equipment then apply the choice
Ø Configure the port parameters according to the characteristics below then apply the settings
• Bits per second : 19200
• Data bits : 8
• Parity : None
• Stop bits : 1
• Flow control : None
. Save the connection settings. The next time you will run the HyperTerminal, just click on the connection icon to connect to the
equipment.
Ø Press "ENTER" twice on the keyboard
The MAIN MENU window appears on screen.
The equipment address will be used to notify alarms and events to the Manager. This address is mandatory when using Unnumbered PPP links ( In the
example below, the Equipment address is 192.168.30.30 ).
: Values to be input
The equipment will be restated after the configuration of the Ethernet port address.
This port's address must be located in the same network as the PC's Ethernet port one (in the example given below, the sub-network address is
135.11.110.8 and the sub-network mask is 255.255.255.252).
NOTE: With Windows 9x, the PC's address can be viewed by selecting (right-click) Properties of the Network Neighborhood icon, then (left-click)
Properties of the TCP/IP component (TCP/IP -> "Network Card Name").
With Windows NT, the PC's address can be viewed by selecting (right-click) Properties of the Network Neighborhood icon, then (left-click)
Properties of the TCP/IP component (TCP/IP protocol).
With Windows 2000/XP, the PC's address can be viewed by selecting, in succession, (right-click) Properties of the My Network Places
icon, Properties of the Local Area Connection icon, then (left-click) Properties of the TCP/IP component (Internet Protocol (TCP/IP)).
: Values to be input
Ø After restarting the equipment, the word Password: appears at the top left of the window. Close HyperTerminal application.
The equipment can now be managed by an HTTP browser.
Example:
To be able to manage the equipment, consult the help menu by clicking on the Help link of the main window.
Example:
Ø Refer to the chapter Connecting to
an ADR155c to configure the
Ethernet port and the Equipment
address of each equipment.
Ø Refer to the chapter Configuring a
PPP port to configure the PPP ports
of each equipment.
Example:
Example:
Ø The three ADR155c units can be managed by an HTTP browser. The management links are secured by the OSPF protocol.
Ø Refer to the chapter Connecting to an ADR155c for managing the equipment by the HTTP browser.
Details on configuring the PPP3 port of ADR155c N°3 and the PPP1 port of ADR155c N°4
When creating a PPP link, the operator has two choices: either the link is numbered or it is
unnumbered. This is independent of the protocol selected (RIP or OSPF). The unnumbered
links do not have an IP address and therefore more easily enable construction of a network
(since there is no need to define all the IP addresses of all the links).
In the ADR155c, the static routes are used to configure routes which are not learned by the
routing protocols and located "on the periphery" of the protocol areas or domains: routes to
machines on Ethernet network such as manager, for example.
The static routes, as implemented in the ADR155c, have the following characteristics:
• each route is assigned a metric.
• each route is assigned a preference. The preference is used to settle conflicts when routes of
different types (static and dynamic) have the same destination.
• preference is given to the static routes with respect to the dynamic routes.
• the static routes are always exported by the routing protocols to the other equipment.
Depending on whether the interface which the routes take is in the operational state or not, the
static routes are set up or removed to avoid assignment of non-valid routes.
A maximum of twenty static routes is supported by each ADR
Configuration of static routes
In the static tables context, each network node must have its routing table filled in order to
correctly route the packets received.
All IP routes of a routing table of a given equipment comprise the following fields:
• «destination @IP» : corresponds to the IP address of the equipment or sub-network (or
network) to be reached from the given equipment,
• «subnet mask» : this is the sub-network mask associated to the IP address defined in the
«destination @IP» ; all equipment with the IP address part defined by the "1" bits of this field
which corresponds to the same value as the «destination @IP» part defined by this same
mask can be reached through this route,
• «next hop @IP» : IP address of next equipment (connected directly with given equipment) to
which the packet will be sent,
• «metric» (also referred to as "cost" or distance): value from 1 to 15 indicating the number of
hops to reach the corresponding equipment at the «destination @IP» address. 16
corresponds to infinity for the RIP routing daemon. This field is only used by a possible
routing daemon to select a preferential route if several different routes exist for the same
destination. It is always possible to configure this field for 1 to simplify if use of the field is not
indispensable.
• «interf.» : interface number used to reach the next equipment (whose IP address is «next
hop @IP»).
Note: Declaration of the interface IP addresses results in setting up implicit static routes to the
associated SUBNETs. It is therefore not necessary to define static routes to join two
equipments on a single SUBNET.
Note: The IP addresses of an equipment are the addresses of its interfaces (or ports) which
have been configured. The manager only knows one IP address per equipment. This is
why reference is often made to the IP address of an equipment to designate the address
configured in the manager database. This is the address of the port by which the
equipment normally dialogues with the manager.
Note: To operate an equipment via a PC and an Ethernet interface, the IP address of the
operation PC must be modified so that it belongs to the same SUBNET as the Ethernet
interface used to connect to the network.
The HOST 1 number on each SUBNET should be left free, i.e. begin to number the
equipment starting with the HOST 2 number. The PC will thus always take an IP
address such as : NET.SUBNET.1
Note: A default router can be defined (option sometimes available) to which all packets which
cannot be routed by the routing table are transmitted.
The figure below gives an example of an IP network and routing tables associated to two typical
equipments. Note that each port of the on-board routing function corresponds to a different
SUBNET.
140.1.1.3
F3
140.1.0.2 140.1.0.3 140.1.1.2
Manager Fiber 140.1.1.4
F1 F2
128.1.0.1 Ethernet
128.1.0.2 F4
Ethernet 140.1.1.5
NET 128.1 128.1.0.3
NET 140 - 1 F5
F6
PPP1 150.1.0.2
Fiber Fiber
150.1.0.3
F7
150.1.1.2
Ethernet Ethernet
Configuration of ADR155C F6
Interfaces
Eth 128.1.0.3
Subnet mask 255.255.0.0
PPP1 150.1.0.2
Subnet mask 255.255.255.0
Static routes
Dest @IP Subnet mask Next hop Interface Metric Note
Configuration of ADR155C F8
Interfaces
Eth 150.1.1.3
Subnet mask 255.255.255.0
Static routes
Dest @IP Subnet mask Next hop Interface Metric Note
Various theoretical cases for a network are described in the sections below.
A.2.2.1 Network 1
This network is the most simple case of an equipment network (starting with release P3.1), all of
which are connected by unnumbered PPP links.
ppp Unn
ADR 2
ppp Unn
ppp Unn
ppp Unn
ADR 3
ADR 1
Ethernet
ppp Unn
sub-network
Ethernet
A RIP or OSPF routing protocol is implemented (RIP only if size of network allows).
The Ethernet network forms an IP sub-network; the Ethernet interface is thus assigned an
address in the sub-network.
The equipment addresses can be selected in any given way, but not in the Ethernet sub-
network.
The breakdown of the number of addresses per equipment thus gives:
ADR 1 has two addresses (Ethernet address and equipment address), ADRs 2 and 3 each have
one address (equipment address).
A.2.2.2 Network 2
This network has ADRs (starting with release P3.1) and a P1 or P2 equipment.
sub-network
ppp Num 3 ADR 4
3
ADR 2
ppp Unn
FOTC 1 ppp Unn ppp Num 2
ADR 3
sub-network
ADR 1
1 ppp Unn
Ethernet
The PPP links respectively connecting ADR 4 and ADR 2 and ADR3 must be numbered links.
The PPP links between ADR1,ADR2,ADR3 will be preferentially unnumbered links.
Equipment addressing:
The Ethernet network forms an IP sub-network.
Each of the numbered PPP links forms an IP sub-network.
The addresses of ADR 1, 2, 3 (equipment address) can be selected in any given way (but not in
the Ethernet sub-network).
To exceed the RIP constraints (limited to 16 "hops"), the network can be divided into two routing
domains in accordance with the diagram below:
Domain 2
ADR 2
Domain 1
ADR 1
ADR 0
Ethernet
The overall equipment network is divided into domains (1 and 2) in which the RIP routing is
implemented.
The Ethernet network is there to represent the link with the SNMP manager on the PC not using
the RIP.
The two domains are connected via ADR 1 and ADR 2 (which functionally are border routers).
The link between the two border ADRs can be an Ethernet link, numbered PPP or unnumbered
PPP.
The RIP is not activated on the interfaces of this link connecting the two domains.
Routing between the two domains is made possible by static routes configured in the ADRs.
ADR 1 has static routes to the sub-networks forming domain 2 and ADR 2 has routes to the sub-
networks forming domain 1.
The static routes to the sub-networks of a domain (2, for example) in the border ADR of the
other domain (ADR 1) can be reduced to a single route to a sub-network combining the sub-
networks of the domain (2).
This global sub-network must be distinct with respect to the sub-networks of the other domain
(1, in the example).
ADR 155C
Le châssis 19" ne doit être monté que dans des baies ou bâtis dont la partie
. inférieure est fermée ou équipée d'un filtre à air classé V1 ou HF1 au
minimum, ou reposant sur un sol non inflammable.
1
Circuit à Très Basse Tension de Sécurité
1.1 - Généralités
L’ ADR 155C est un multiplexeur add-drop optique STM-1/STM-4 qui permet de construire des
liaisons point à point STM-1, des anneaux STM-1 ou STM-4 ou des réseaux maillés, avec
protection de conduit (SNC) ou de ligne STM-1 (MSP), réalisant ainsi le transport de liaisons à 2
Mbit/s, 34 ou 45 Mbit/s, Ethernet, STM-1.
L'ADR 155C prend place dans une baie 19" ou un bâti ETSI. Il est constitué :
§ d'un châssis 2U équipé d'une carte-mère regroupant les fonctions de base de l'équipement,
parmi lesquelles 21 accès 2 Mbit/s G.703, d'un fond de panier et d'une alimentation 48V DC
sécurisée,
§ d'un module ADRFAN, composée de deux blocs de ventilation redondants,
§ de quatre cartes d’accès au choix :
§ carte d’accès STM1 optique IC1.1 ou IC1.2 (carte ADR IC1.1 ou ADR IC1.2) ou MM1
(carte ADR MM1) ou S1.1 (carte ADR S1.1) ou L1.1 (carte ADR L1.1) permettant une
connexion VC4 ou 3 connexions VC3 ou 63 connexions VC12 ou un mixte de
connexions VC3/VC12,
§ carte d’accès STM1 électrique (carte ADR ERE) permettant une connexion VC4 ou 3
connexions VC3 ou 63 connexions VC12 ou un mixte de connexions VC3/VC12,
§ carte d’accès STM4 optique S4.1, L4.1 ou L4.2 (cartes ADR S4.1, ADR L4.1, ADR
L4.2) permettant une connexion VC4 ou 3 connexions VC3 ou 63 connexions VC12 ou
un mixte de connexions VC3/VC12,
§ carte d'accès Ethernet 10/100 (carte ADRLAN1), permettant 2 connexions VC3,
§ carte d'accès Ethernet 10/100 (carte ADRIMA), permettant 8 connexions VC12,
§ carte d'accès 8 interfaces Ethernet 10/100 (carte ADRGFP150), permettant 63
connexions VC12 ou 3 connexions VC3 répartis sur 8 groupes en concaténation
virtuelle,
§ carte d'accès 34 ou 45 Mbit/s G.703 (carte ADRE3DS3) permettant une connexion
VC3,
§ carte d'accès 21 x 2 Mbit/s G.703 (carte ADR21E120/ADR21E1R8), permettant 21
connexions VC12.
Pour le raccordement des différents accès des cartes voir § 1.3 - Raccordement des accès
A
V
M
C
Montants
de la baie
ADR 155C
ADR 155C bâti ETSI
bâti 19"
76 76
,2 ,2
m m 2U
m m
2U
SYNC E1 OUTPUT
SYNC E1 OUTPUT
2 2
2 vis HS 2 vis HS
1 M6x12 1 M6x12
2 écrous 2 écrous
cage M6 cage M6
Montage en bâti 19" Montage en bâti ETSI
1.2.1 - Généralités
Le châssis ADR 155c peut s'installer en baie 19" ou en bâti ETSI. (voir Figure 1-1 - Installation
du châssis ADR 155C)
Dans l‘emballage de l'ADR 155c, est fourni un lot de montage pour l’adaptation du châssis à une
baie 19" ou à un bâti ETSI.
Ce lot contient :
§ deux équerres pour adaptation à une baie 19"
§ deux équerres pour adaptation à un bâti ETSI
§ 2 vis M3x4
§ 2 rondelles plates M3
§ 8 vis CBLXS M3x6 pour fixation des cartes optionnelles
Le lot de montage du châssis sur les montants de la baie 19" ou du bâti ETSI, constitué de
4 écrous cage et de 4 vis M6x12, n’est pas fourni avec le châssis.
RAPPEL : Avant toute intervention sur les cartes, l'opérateur doit se munir d'un bracelet
antistatique.
Les alvéoles d'un ADR 155C sont banalisées. Cependant pour faciliter le câblage et garantir
l'homogénéité des sites il est recommandé de procéder de la façon suivante :
§ positionner les cartes affluents depuis l'alvéole C dans le sens des aiguilles d'une montre
§ positionner les cartes résultants depuis l'alvéole D dans le sens inverse des aiguilles d'une
montre
§ vérifier la présence du module de ventilation dans son tiroir réservé,
§ l'ADR 155c est fourni avec la carte-mère et le module de ventilation déjà mis en place.
Fixer chaque carte au moyen des vis de type Torx de type M3 (étoile à 6 branches) en
utilisant un tournevis adapté, tel que :
§ FACOM : tournevis industriel empreinte torx n°10 réf. AZX.10X75
§ ou STANLET tournevis Magnum vis à tête torx TX10 réf. 1-67-494.
Les raccordements, autres que les raccordements à 2 Mbit/s effectués sur le bandeau 75 ohms,
sont situés en face avant du châssis.
Les cartes peuvent être extraites sans intervention sur les autres cartes ou sur les
raccordements de celles-ci.
Les raccordements à effectuer sur l'équipement sont fonction de la configuration choisie :
Sur le bandeau d'alimentation :
§ accès d'alimentation : "PWR" ou "PWRA" et/ou "PWRB",
Sur le bandeau de la carte-mère du châssis :
§ accès de télésignalisation, de télécommandes et d'alarmes station "LOOPS".
§ accès de configuration de l'adresse IP "COMM" : permet le raccordement à un terminal ou
émulation VT100.
§ accès de gestion Ethernet "ETH"
§ accès de gestion ou de trafic 2Mbit/s X24/V11 "MNGT"
§ accès de synchronisation 2Mbit/s G.703 "SYNC".
§ accès de trafic 21x2Mbit/s G.703 "E1 INPUT / E1 OUTPUT".
Sur la carte d'accès STM-1 optique :
§ 1 accès STM-1 optique G.957 "TR / REC"
§ 2 accès de voies de service "AUX" et "EOW"
Sur la carte d'accès STM-4 optique :
§ 1 accès STM-4 optique G.957 "TR / REC"
§ 2 accès de voies de service "AUX" et "EOW"
Sur la carte d'accès STM-1 électrique :
§ 1 accès STM-1 électrique G.703 "TR / REC"
§ 2 accès de voies de service "AUX" et "EOW"
Sur la carte ADR21E120/ADR21E1R8 :
§ 1 accès de trafic 21x2Mbit/s G.703 "E1 OUTPUT / E1 INPUT"
Sur la carte ADRE3DS3 :
§ 1 accès de trafic 34 ou 45 Mbit/s G.703 "TR / REC"
Sur la carte ADRLAN1 :
§ 1 accès de trafic Ethernet "ETH"
Sur la carte ADRIMA :
§ 1 accès de trafic Ethernet "ETH"
Sur la carte ADRGFP150 :
§ 8 accès de trafic Ethernet "ETH"
Règles de raccordement
ð Pour une bonne répartition des cordons de part et d'autre du châssis, les raccordements des
alvéoles A et C, les 21 accès 2Mbit/s et l'accès de synchronisation sont orientés vers la
gauche. Tous les autres raccordements sont orientés vers la droite.
ð Le passage des cordons ne doit pas gêner l'extraction d'un module ; en particulier, les câbles
de raccordement de la moitié gauche du châssis doivent être assujettis au bâti avec un mou
suffisant afin de permettre l'extraction du module de ventilation lors d'une opération de
maintenance.
ð Les accès d'alimentation "PWR" et "PWRA" et/ou "PWRB" peuvent être connectés
simultanément.
ð Toujours raccorder le côté équipement avant le côté source d'énergie.
ð Le bloc d'alimentation doit être installé de telle sorte qu'il soit éloigné de toute source de
chaleur et qu'aucune traction ne puisse être exercée sur ses fils de raccordement.
ð Le câble utilisé pour relier le bloc d'alimentation à la source d'énergie doit avoir une section
de 1.5 mm² minimum, et être de qualité <HAR> H03 VV_F ou <HAR> H03 VVH2_F.
ð La liaison de terre entre le bloc d'alimentation et la source d'énergie doit être respectée.
ð Le raccordement à l'installation électrique doit être réalisé conformément aux normes
nationales en vigueur.
POWER
- 48V
2A MAX
"PWR"Connecteur de type Jack
PWRA et PWRB
1 - 48 B1
9
5 2 - 48 B1 6 OB1
3 - Réservé 7 OB1
6
1 4 - 48 B2 8 OB2
5 - 48 B2 9 OB2
ADR-155C
Figure 1-2 - Raccordement des accès alimentation
Interface d'alimentation "PWRA"/"PWRB" :
Tension d'entrée : Une ou deux sources d'alimentation - 48 V de type TBTS (Très
Basse Tension de Sécurité)
Plage de tension autorisée : - 36 V à - 60 V
Plage de tension maximale : - 36 V à - 72 V
Puissance 100 VA maximum
Connecteur HE5 9 points mâle
5 1
9 6
LOOPS
8 1
15 9
1 : Break B
2 : Make B 9 : Common B
3 : Common A 10 : Break A
4 : Gnd 11 : Make A
"SYNC" 5 : R-MON 4 N 12 : R-MON 4 P (OB)
6 : R-MON 3 N 13 : R-MON 3 P (OB)
5 1 7 : R-MON 2 N 14 : R-MON 2 P (OB)
9 6 8 : R-MON 1 N 15 : R-MON 1 P (OB)
1 : GND Schéma de principe
d'une boucle sèche au repos
2 : TX1_TIP 6 : TX1_RING
3 : RX1_TIP 7 : RX2_TIP
4 : RX2_RING 8 : RX1_RING MC B
5 : RESERVE 9 : RESERVE
5 1 1 : TX_ETH_TIP 5 : NC
2 : TX_ETH_RING 6 : RX_ETH_RING
9 6 3 : RX_ETH_TIP 7 : NC
COMM
1 : GND 4 : NC * 8 : NC
5 1
2 : RXPA 6 : RXPB Voyant droit : état de la liaison
9 6
3 : TXPA 7 : TXPB allumé : liaison correcte
4 : TXCLKPA 8 : TXCLKPB 1 : DCD
Voyant gauche : état du trafic
2 : RX 6 : DSR
5 : RXCLKPA 9 : RXCLKPB allumé : émission en cours
3 : TX 7 : RTS
4 : DTR 8 : CTS NC * : Réservé
5 : Gnd 9 : NC *
NOTA : OB est le "OU" logique des signaux OB1 et OB2 des interfaces alimentation "PWR", "PWRA" et "PWRB".
Interface "COMM" :
Accès Interface RS232, interconnexion d’une console ou émulation au
standard VT100
Débit 19200 bauds (8 bits de données, pas de bit de parité et 1 bit de
stop),
Connecteur Type HE5 – 9 points femelles (voir tableau ci-après)
5 1
9 6
Schéma de cablage
1 1
6 6
9
5 9
5
Interface "ETH" :
Accès Interface Ethernet de gestion fonctionnant à 10 Mbit/s en mode half
duplex ou full duplex selon le mode utilisé par l’interlocuteur
(adaptation dynamique du port Ethernet à chaque nouvelle
connexion de l’interlocuteur),
Connecteur Type RJ48 (RJ45 blindé).
Contact 8 Contact 1
vue de face
*En mode contradirectionnel esclave (entrant) les signaux TXCLK sont des entrées.
TXP (B-A)
(sortie données émises B8 B1 B2
sur l'interface P)
RXCLKP (B-A)
(entrée horloge de réception)
RXP (B-A) B8 B1 B2
(entrée données reçues
sur l'interface P)
Interface "SYNC"
Accès 2 Interfaces d'entrée de synchronisation externe à 2 MHz G.703
(T3) et une interface de sortie de synchronisation à 2 MHz G.703
(T4) Conforme à la recommandation G.703 de l'UIT-T (§ 13.3 pour
l'interface d'entrée, § 13.2 pour l'interface de sortie)
Impédance 120 Ω symétrique,
Connecteur HE5 9 points femelles (120 Ω).
5 1
9 6
NOTA : Le blindage du connecteur est relié à la masse électrique de la face avant du châssis
Deux connecteurs sont associés aux accès : les appellations (RX) correspondent à celles du
connecteur E1 INPUT et les appellations (TX) à celles du connecteur E1 OUTPUT.
15 1
30 16
44 31
NOTA : Le blindage du connecteur est relié à la masse électrique de la face avant du châssis
ADR IC1.1
"EOW et "AUX"
Voyants STATUS 8 1
15 9
Vert Rouge
NC : Réservé
Figure 1-4 - Raccordement sur les modules ADR Optique ADR IC1.1 et ADR IC1.2
(Connecteur FC/PC)
Accès STM-1 émission
Accès STM-1 réception
EOW et AUX
Voyants STATUS 8 1
Vert Rouge 15 9
Figure 1-5 - Raccordement sur les modules ADR Optique ADR S1.1, ADR L1.1, ADR MM1
ADR S4.1, ADR L4.1 et ADR L4.2
(Connecteur SC/PC)
T64 (B-A)
(sortie horloge d'émission)
T (B-A) B8 B1 B2
(entrée données à transmettre
sur la ligne STM1/STM4)
TOFP (B-A)
(sortie synchro octet
en émission)
R64 (B-A)
(sortie horloge de réception)
R (B-A)
(sortie données reçues B8 B1 B2
de la ligne STM1/STM4)
ROFP (B-A)
(sortie impulsion de trame
en réception)
Les accès EOW et AUX étant physiquement solidaires des modules optiques, l'exploitation des
voies de service et voie auxiliaire avec protection MSP nécessite l'utilisation d'un cordon en Y
reliant électriquement un à un à l'identique les signaux des connecteurs EOW et AUX.
Cordon en Y Cordon en Y
pour exploitation pour exploitation
de la voie de service de la voie auxiliaire
De même pour garantir un bon comportement lors du basculement d'un module sur l'autre,
l'opérateur doit veiller à conserver une configuration identique sur les deux cartes ADR Optique ;
en cas de modification, une recopie automatique est effectuée et un message d'avertissement
apparaît.
Seules les connexions ne sont pas identiques. Il ne doit pas y avoir de connexions sur le module
en "Protection" toutes les connexions étant créées sur le module "Working".
Par ailleurs, il faut veiller à créer les liens de gestion sur le module « Working » et non sur le
module « Protect »
ADR ERE
"EOW et "AUX"
Voyants STATUS 8 1
15 9
Vert Rouge
NC : Réservé
ADR LAN1
Voyants STATUS
HALF/FULL
Vert Rouge
Voyant jaune : nature de l'interface
Allumé Eteint Carte en service Ethernet
Allumé Allumé Carte en alarme (Half ou Full Duplex)
Eteint Eteint Défaut matériel de la carte (fusible)
Eteint Allumé Carte hors service Allumé : Full duplex
Clignotant Défaut autotest
10/100
ADRIMA
STATUS TX LNK
ETH
Voyants STATUS
Vert Rouge
1 8
STATUS ETH
Voyant STATUS
Vert Rouge
Allumé Eteint Carte en service
Allumé Allumé Carte en alarme
Eteint Eteint Défaut de la carte (fusible)
Eteint Allumé Carte hors service
clignotant Défaut autotest
Contact 8 Contact 1
vue de face
Les cartes ADRLAN et ADRIMA présentent un interface Ethernet « droit ». La carte ADRGFP150 présente, selon sa
configuration , un interface droit ou croisé.
ADR E3DS3
STATUS DS3 E3
TR REC 45 34
Les raccordements de trafic à 2 Mbit/s effectués sur les accès "E1 INPUT" et "E1 OUTPUT" de
la carte ADR21E120/ADR21E1R8 sont identiques à ceux effectués sur les accès "E1 INPUT" et
"E1 OUTPUT" de la face avant de la carte-mère (voir § 1.3.2.5)
Note : sur la carte ADR21E1R8, seuls les ports #1 à #8 supportent la fonction retiming
ADR 21E120
Voyants STATUS
"E1 OUTPUT" et "E1 INPUT"
Vert Rouge
15 1
30 16
Allumé Eteint Carte en service 44 31
Allumé Allumé Carte en alarme
Eteint Eteint Défaut matériel de la carte (fusible)
Eteint Allumé Carte hors service
Clignotant Défaut autotest
Caractéristiques du connecteur
Le bandeau de raccordement 75 Ω est livré avec ses équerres de fixation, réversibles pour
installation en baie 19" ou ETSI.
§ Fixer le bandeau sur les montants du bâti, au-dessus ou en dessous du châssis ADR 155C.
§ Enficher respectivement les connecteurs "E1 INPUT", "E1 OUTPUT" et 'SYNC' sur les
connecteurs (120 Ω) de même nom du châssis ADR 155C.
§ Effectuer les raccordements en 75 Ω :
§ Accès émission (TX) 1 à 21 : ligne supérieure du bandeau,
§ Accès réception (RX) 1 à 21 : ligne inférieure du bandeau,
§ Accès SYNC (TX et RX) : deux connecteurs à la droite du bandeau.
FACE ARRIERE
FACE AVANT
TEST LOCAL
Inventaire du matériel
Contrôle de redondance du - 48 V
Raccordement optique
Elaboration de la configuration
oui
Mise en liaison
Mesures optiques
Qualité 24 H en liaison
Equipement opérationnel
(constitution du dossier d'installation)
Sauvegarde de la configuration
L'exploitation de l'équipement peut être réalisée à partir d'un PC équipé d'une émulation VT100
et du navigateur HTTP ; sa configuration minimale est définie au paragraphe 5.2 du "Guide de
Démarrage".
Un terminal local avec émulation VT100 est indispensable lors de la première mise en service,
afin de pouvoir accéder à l'équipement via la fonction de gestion ; toutefois, celui-ci ne permet
que le paramétrage de la fonction communication (définition de l'adresse IP de l'équipement).
Procédure.
F A la première mise en service, l'équipement scrute sa constitution et la prend comme
configuration attendue, en service, monitoré. Il est donc conseillé d'insérer toutes les cartes
d'accès avant la mise sous tension afin d'accélérer la mise en service.
F Mettre en marche l'alimentation raccordée à l'équipement.
F L'équipement effectue des auto-tests :
§ lorsque les auto-tests se sont déroulés correctement, le voyant "ON" est allumé,
§ dans le cas contraire, un code de clignotement du voyant définit l'auto-test défaillant
(contacter la hot line).
F Paramétrer l'interface de communication à l'aide de la VT100 (voir § 1.4.2).
F A l'aide du navigateur HTTP, (voir § 1.4.3).
§ Mettre à jour l'heure et la date de l'équipement
§ Configurer les ports de la gestion distante, à l’aide de l’interface HTTP
F Raccorder les accès 2 Mbit/s, 34/45 Mbit/s, Ethernet, STM-1, STM-4 et SYNC nécessaires,
selon la constitution de l'équipement,
F Raccorder les accès AUX et EOW nécessaires.
F Télécharger une configuration prédéfinie ou élaborer la configuration souhaitée à l'aide du
navigateur HTTP :
§ Créer les connexions
§ Etablir les sécurisations souhaitées (protection MSP, protection SNC ..)
§ Choisir la source de synchronisation et modifier ses paramètres si nécessaire.
§ Modifier si nécessaire les paramètres de surveillance et la configuration des alarmes
La configuration par défaut des différents paramètres est donnée au § 2.3.
F Effectuer les tests des liaisons STM-n en respectant le processus décrit à la Figure 1-13.
F L'équipement est dès lors opérationnel.
F Les alarmes d'exploitation peuvent signaler un mauvais raccordement des accès. Vérifier le
raccordement des accès, les alarmes qui correspondent aux accès raccordés et corriger les
problèmes éventuels.
F Effectuer une sauvegarde de la configuration.
REMARQUE : Il est possible, une fois la mise en service effectuée, de raccorder des accès
supplémentaires 2 Mbit/s G.703, E3/DS3, Ethernet,STM1 ou STM-4et d'insérer ou
d'extraire des cartes sous tension.
S NMP x S NMP
IONOS
ET H
Le "TPI" peut se brancher sur une
interface Ethernet quelconque dès lors
S H
N T
que le paramètrage permet d'atteindre
un équipement à exploiter M R T
ADR
P P
PP P
D1 - D 3 D1 - D 3
sur STMn sur STMn
Ouest Est
D 1 - D 3 STMn
HTTP on East
E P
ADR T
H
R P
P
D 1 - D 3 sur
SN MP STMn Oue st
S NMP
Pour sélectionner une commande, taper le numéro de la commande dans la zone de texte
"Choice ?" et appuyer sur la touche "ENTER" pour valider votre choix.
L'écran visualise les routes de gestion déjà définies avec leurs caractéristiques :
Ø Hops : saut 1, 2, 3…Chemin pour passer d’une machine à une autre.
1 2 3
Configuration IE 5.0
REMARQUE : Il est préférable de ne pas avoir de cache avec IE 5.0, sinon, il n’est jamais
certain d’avoir à l’ouverture de l’écran, des données actualisées.
1. Dans le menu Outils d’Internet Explorer, cliquez sur Options Internet.
2. Sous l’onglet Général, cliquez sur Paramètres.
3. Cochez le bouton radio A chaque visite de la page, puis définissez à 1 Mo l’espace
disque à utiliser. Cliquez sur [OK].
4. Sous l’onglet Fichiers Internet temporaires, cliquez sur Supprimer les fichiers.
5. Cochez Supprimer tout le contenu hors connexion, puis cliquez sur [OK].
6. Dans la boîte de dialogue Options Internet, cliquez sur [OK], puis fermez le navigateur IE
ouvert pour que les options soient prises en compte.
Remarque
Après un upgrade du code applicatif, il faut vider le cache comme suit :
Dans le menu "Outils" d'Internet Explorer cliquer sur "Options Internet / onglet Général / onglet
Fichiers temporaires Internet / Supprimer les fichiers"
Cocher "Supprimer tout le contenu hors connexion", puis cliquer "OK"
Puis fermer et relancer le Navigateur
Configuration PC
Afin que la date HTTP d'un équipement soit correcte, la variable d'environnement "TZ" ne doit
pas être définie. Pour obtenir la liste de toutes les variables d'environnement, taper "Set" dans la
console DOS.
Par ailleurs, afin d'obtenir un affichage correct des pages HTML, vérifier que les polices ne sont
pas définies comme "grandes" dans les propriétés d'affichage du panneau de configuration.
Le PC est connecté via Ethernet (la gateway du PC doit être dans le même sous-réseau que
l'interface Ethernet de l'ADR)
§ Si un écran de résolution 860 x 600 est utilisé, réduire la police de caractère afin
d'obtenir un affichage correct des pages écran (à titre d'exemple, l'écran
synchronisation doit comporter 3 boutons 'Apply')
§ Lors de la première mise en service, le mot de passe est vide ; cliquer sur Apply pour
accéder à l'écran "Shelf View"
§ le contour des modules est en rouge dans le cas d'une alarme d'insertion (Missing, Mismatch
detection),
§ les éléments à l'intérieur des modules en alarme sont encadrés en rouge dans le cas d'une
alarme majeure, en jaune pour une alarme mineure,
§ les modules configurés hors surveillance sont représentés en grisé,
§ les modules présents, configurés hors service comportent une croix rouge pour signaler cet
état administratif,
§ les modules absents, configurés hors service apparaissent sous forme d'un panneau
entièrement blanc.
Pour chaque fonction visualisée, les paramètres de configuration, les commandes d'exploitation,
les paramètres actifs et l'état des alarmes sont regroupés sur le même écran, les différentes
actions possibles étant accessibles ou non à l'opérateur selon son niveau d'habilitation.
Le bord supérieur de la fenêtre du navigateur rappelle le nom de l'équipement, son adresse IP,
le niveau d'habilitation acquis et, si besoin, l'alvéole concernée.
LOGIN
Menu "ADR21E120" Menu " ADR STM-1 Optique" Menu "ADR STM-4" Menu "Carte mère"
ou Menu "ADRERE"
Maintenance
Maintenance Maintenance
Monitoring Maintenance
Monitoring Monitoring
Service Monitoring
Service Performance :
Expected Card Service VC12 Near (# 1 to 21)
Expected Card
Performance : Expected Card VC12 Far (# 1 to 21)
Performance :
VC12 Near (#1 to 21) Performance : Board status
VC12 Near / VC12 Far #
VC12 Far (# 1 to 21) VC12 Near / VC12 Far # VC3 Near / VC3 Far # 2M Ports
Board status VC3 Near / VC3 Far # VC4 Near / VC4 Far #
VC4 Near / VC4 Far MNGT Port
2M Ports MST Near / MST Far /
MST Near / MST Far / IP Parameters
RST Near
RST Near Loops
Board status
Board status
Menu "ADR21E1R8" EOW
EOW
AUX
AUX
STM4's Functional Menu "ADRIMA"
STM's Functional Groups Groups
Maintenance
Protection STM1 Selection
Monitoring
Service Monitoring
Expected Card Service
Performance : Expected Card
VC12 Near (#1 to 21) Board status
VC12 Far (# 1 to 21)
IMA Ethernet
Board status
IMA's Functional Groups
Retiming
2M Ports Menu "ADRE3DS3" Menu "ADRLAN1"
Menu "ADRGFP"
Menu "ADRFAN"
Expected card
2. EXPLOITATION
2.2 - Généralités
L'exploitation et la maintenance de l'ADR 155C sont réalisées:
- soit directement sur l'équipement, au moyen des voyants de la face avant et des deux
boucles de gestion technique (boucles A et B),
- soit à partir d'un PC équipé d'un navigateur HTTP,
- soit à partir d'un gestionnaire de réseau par l'utilisation du protocole SNMP pour les aspects
réseau et supervision, et du navigateur HTTP inclus.
Paramètres de configuration
NOTA :
1) La dénomination des blocs fonctionnels, les paramètres de configuration et leur valeur par
défaut, notés "XXXXXX", sont visualisés sur le navigateur HTTP.
2) Les valeurs par défaut sont indiquées en présence d'une connexion.
"TIMdis" (Invalidation du TIM -Trace Identifier Mismatch) actif ou non Actif (pas de TIM)
LUG : Générateur de conduit d'ordre inférieur non équipé
(Lower order path Unequipped Generator)
Numéro des VC12s non équipés émis dans les TUG3s "FFH"
(par défaut, pas de connexion)
LPOM : Surveillance de préfixe de conduit d'ordre inférieur
(Lower order Path Overhead Monitor)
"Label Rec"
Etiquette signal (VC12) reçue – Valeur affichée non configurable
"Label Rec"
Etiquette signal (VC3) reçue - Valeur affichée non configurable
"SD threshold"
-5 -9
Seuil SD : configurable de 10 à 10 pour VC3 -6
-5 -9
configurable de 10 à 10 pour VC12 "10 "
LPC : Connexion de conduit d'ordre inférieur (Lower order Path Connection)
HPC : Connexion de conduit d'ordre supérieur (High order Path Connection)
Matrice de connexion – Menu "Cross-Connection > Configure ou Non mise en
service
Multiple connections" (après sélection d'un port d'entrée)
"Name"
Identification des connexions Pas de nom
(configurables conformément à M.1400 §13)
Module ADRLAN1
Etiquette signal (VC3# i) transmise, attendue et reçue; "Label" :
- "Sent" non configurable "A8H"
- "Expected" non configurable "A8H"
- "Received" non configurable
"SD threshold" -6
-5 -9 "10 "
Seuil SD : configurable de 10 à 10 pour VC3
Configuration du port Ethernet (choix exclusif)
"automatic" (ou auto-négociation) avec 4 modes de fonctionnement
possibles, non exclusifs 100Mbps Full
"Manual" avec sélection d'un seul mode de fonctionnement parmi les Duplex
quatre possibles
Mode de fonctionnement disponibles :
- 100Mbps Full Duplex
- 100Mbps Half Duplex
- 10Mbps Full Duplex
- 10Mbps Half Duplex
Contrôle du flux (en mode multi-point uniquement)
- LAN vers VC3_# i 60 %
- VC3_# i vers VC3_# j ou LAN 60 %
Configuration des interfaces
- LAN en service / hors service Service
- Age maximum du routage 300 s
- mode d'interconnexion de LAN (point à point sur 2VC3/ point multipoint) multi-point
- Path trace J1 émis : "UNNAMED VC3"
"UNNAMED VC3" + CRC7 non configurable et non traité en réception + CRC7
Module ADRIMA
- Pour la configuration de ce module on se reportera au guide de
démarrage de ADRIMA
Module ADRGFP150
- Pour la configuration de ce module on se reportera au guide de
démarrage de ADRGFP150
Etiquette signal (VC3# i) transmise, attendue et reçue; "mappage GFP" :
- "Sent" non configurable "1BH"
- "Expected" non configurable "1BH"
- "Received" non configurable
Etiquette signal (VC12# i) transmise, attendue et reçue; « Etiquette de
signal étendu » / « mappage GFP » : "101b / 1101b "
- "Sent" non configurable "101b / 1101b "
- "Expected" non configurable
- "Received" non configurable
"Minimum Quality"
Seuil de qualité pour T4
- "PRC" (Primary Reference Clock),
- "SSUT" (Synchronisation Supply Unit Transit), "PRC"
- "SSUL" (Synchronisation Supply Unit Local),
- "SEC" (Synchronisation Equipment Clock),
"Sase"
Contrôle du mode SASE (activation ou désactivation) False
Choix de la source T3 pour le mode SASE (T3-1 ou T3-2) T3-1
"Default Edge"
Module ADRE3DS3
"E3 (34M)" ou "DS3 (45M)"
Choix de l'interface physique 34 ou 45 Mbit/s "E3 (34M)"
Sélection de la longueur du câble de raccordement afin que l'impulsion
émise soit conforme au gabarit défini dans la norme Bellcore GR-489-
CORE : "Type of cable" (mode DS3/45Mbit/s uniquement) "short"
"long" ou "short" (longueur < 225ft soit 70m)
Tableau 2.9 – Paramètres de configuration (8/13)
Synchronisation
La synchronisation de l'équipement local et de l'équipement distant est gérée en fonction des
sources de synchronisation disponibles, de leur qualité et de la priorité qui leur a été attribuée.
Les sources de synchronisation possibles sont :
§ fonctionnement en autonome (oscillateur local),
§ T1 extraites de l'un des trains STM-n entrants (1 à 4 possibilité selon le nombre de cartes
ADR Optiques présentes dans l'équipement),
§ T2 : une source 2 Mbit/s G.703 par module 2 Mbit/s déclaré et sélectionnée parmi les
différents accès 2 Mbit/s G.703
§ T3 : deux sources externes 2 MHz G.703
Entrée de synchronisation
externe aà 2 MHz (T3) :
- Qualité = PRC,
- Priorité = 1. Accès STM-n (T1-c) =: Accès STM-n (T1-c) =:
- Qualité = DNU - Qualité = DNU
- Priorité = 2. - Priorité = 2.
ADR155C 1 ADR155C 2
ADR155C 3
SSM = PRC
T0 = T1-c
Synchronisation
d'autres équipements
Synchronisation
ADR155C 3
d'autres équipements
SSM = SEC
T0 = T1-c
Synchronisation
d'autres équipements
NOTA : La synchronisation se fait sur l'accès à 2 Mbit/s de l'ADR155C qui est mis en service le
premier (ADR155C local dans l'exemple).
A B Local useroutputs
EST Activation de local OUEST
user inputs
S1 = S1 reçu * + état de Local #1 ou #2 suite S1 = S1 reçu * + état de Local
user inputs #1 et #2 à activation user inputs #1 et #2
#1 de local user
outputs A ou B
#2 (alarmes
#3 équipement
S1 reçu* : collecte des S1 reçus ou local user
S1 affluent
sur les interfaces autorisées à #4 inputs #3 rt #4)
STMn reçu
l'exception de l'interface émettrice Local ADR 155C 3
User inputs
Figure 2-3 - Déport de boucles (rapatriement des alarmes sur un site central)
NOTE 1: Lorsque les boucles entrantes #1 et #2 (Local user inputs #1 et #2) collectent les
informations d'alarme majeure et mineure ((Local user outputs A et B), il est impératif
de leur affecter une sévérité "néant" pour éviter une activation permanente.
NOTE 2 :L'état des boucles entrantes (Local user inputs #1 à #4), des boucles entrantes
distantes (Far user inputs #1 et #2) et des boucles sortantes (Local user outputs A et B
peut être visualisé à partir du navigateur HTTP.
ð Boutons poussoirs :
Appellation Localisation Rôle Conséquence à la mise en oeuvre
"ACK" Carte mère Acquittement L'appui désactive les boucles d'alarmes
des alarmes sortantes. L'alarme visuelle est
maintenue.
"INIT Carte mère Rechargement Rechargement de la configuration
CONFIG"* configuration "constructeur"
* Pour mettre en œuvre le bouton poussoir "INIT", appuyer dessus pendant 5 secondes
minimum. Ce bouton poussoir est inaccessible (et inutilisé) en exploitation normale. La
dépose du capot est nécessaire pour son accessibilité.
Défauts et Alarmes
Les tableaux ci-après donnent les valeurs par défaut des gravités associés aux défaillances.
DEFAUTS 1 2 3 4 5 6
DEFAUTS TF LOS LOF AIS SD-B2 RDI
1 TF
2 LOS
3 LOF X
4 AIS (MS-AIS) X X
5 SD-B2 X X X
6 RDI (MS-RDI) X X X
DEFAUTS 1 2 3
DEFAUTS PAM SCM OTM
1 PAM
2 SCM X
3 OTM X
DEFAUTS 1 2 3 4 5 6 7 8
DEFAUTS AU-AIS AU-LOP UNEQ RDI SLM TU-LOM TIM SD-B3
1 AU-AIS
2 AU-LOP
3 UNEQ (VC4 UNEQ) X X
4 RDI (VC4 RDI) X X X X
5 SLM X X X X
6 TU-LOM X X X X X
7 TIM X X X
8 SD-B3 (VC4) X X X
DEFAUTS 1 2 3 4 5 6
DEFAUTS TU-AIS TU-LOP LP-UNEQ LP-RDI LP-SLM LP-SD
1 TU-AIS
2 TU-LOP
3 LP-UNEQ X X
4 LP-RDI X X X
5 LP-SLM X X X
6 LP-SD X X
DEFAUTS 1 2
DEFAUTS LOS AIS
1 LOS
2 AIS X
Le résultat de ces calculs est ensuite cumulé pour chaque point de surveillance dans :
§ des compteurs 24 heures (BBE, ES, SES et UAS),
§ et des compteurs 15 minutes (BBE, ES, SES et UAS).
Les six dernières périodes d'indisponibilité (UNAVAILABLE PERIODS) sont conservées et
visualisables à partir du navigateur HTTP.
Le traitement de la qualité est initialisé dés que l'équipement est mis sous tension et que le point
de surveillance est activé ('monitored').
Les 16 derniers compteurs 15 minutes non nuls, le compteur 15 minutes courant, le dernier
compteur 24 heures non nul, le compteur 24 heures courant et les 6 dernières périodes
d'indisponibilité sont visualisables à partir du navigateur HTTP.
Observations :
§ Des alarmes apparaissent lorsqu'une carte est extraite du châssis. Afin d'éviter la remontée
des alarmes M/m et boucles ALA 1 et ALA 2, la carte doit être déclarée hors service.
§ Chaque module peut être extrait ou inséré sans intervention sur les autres modules ou leur
câblage. Seul le trafic du module concerné est perturbé.
Procédure :
La procédure décrite ci-dessous peut s'appliquer, sauf indication contraire, à toutes les cartes de
l'équipement.
1. Mettre la carte concernée "hors service" à partir du navigateur HTTP.
2. Retirer les raccordements externes, effectués sur la face avant de la carte.
NOTA : Lorsque les fibres optiques externes sont déconnectées, remettre en place
les capots de protection des connecteurs.
3. Dévisser les vis TORX situées en face avant à l'aide du tournevis adapté et désenficher la
carte
4. Extraire la carte en respectant les mesures de protection contre les décharges
électrostatiques.
NOTA : Pour toute manipulation de carte, l'opérateur doit être équipé d'un bracelet
anti-statique bien serré au poignet et relié à la terre.
5. Conditionner la carte dans un sachet anti-statique.
6. Sortir la nouvelle carte de son sachet anti-statique.
7. Insérer avec précaution la carte dans son alvéole en respectant les mesures de protection
contre les décharges électrostatiques et la fixer avec les vis TORX.
8. Rétablir les raccordements en face avant de la carte.
NOTA : Pour la carte STM-n optique, retirer les capots de protection des
connecteurs.
Pour nettoyer les connecteurs optiques, utiliser une bombe d'air sous
pression.
9. Configurer la carte, si nécessaire, et la mettre en service.
Le module ADRFAN est composé de deux ventilateurs redondants afin d'assurer une ventilation
suffisante lors d'une défaillance de l'un d'entre eux. Les pannes des ventilateurs sont détectées
sur la carte-mère par surveillance du courant consommé ; elles sont visualisées dans l'écran
d'accueil " Shelf View" du navigateur HTTP.
La configuration par défaut des sévérités des défauts du module ADRFAN amène le
comportement suivant :
§ Si le module ADRFAN est encadré en jaune, un des deux ventilateurs est en panne (alarme
mineure),
§ Si le module ADRFAN est encadré en rouge, les deux ventilateurs sont en panne (alarme
majeure).
NOTA : le fonctionnement des ventilateurs du module ADRFAN n'est pas
systématique ; le déclenchement est lié à la température interne de
l'équipement et au choix du mode de fonctionnement.
Le module ADRFAN est extractible, il peut être remplacé à tout moment sans perturbation du
trafic.
Procédure :
1. Dévisser les vis TORX situées en face avant à l'aide du tournevis adapté et désenficher le
module
2. Extraire la carte en respectant les mesures de protection contre les décharges
électrostatiques.
NOTA : Pour toute manipulation de carte, l'opérateur doit être équipé d'un bracelet
anti-statique bien serré au poignet et relié à la terre.
3. Conditionner le module dans un sachet anti-statique.
4. Sortir le nouveau module de son sachet anti-statique.
5 Insérer avec précaution le module dans son emplacement en respectant les mesures de
protection contre les décharges électrostatiques et le fixer avec les vis TORX.
Remplacement du fusible de face avant
Procédure :
3. RECHANGES ET CORDONS
ADR 155c
ADR 155c CORPS 19"/ETSI 21E1 STM1/4 NR A155 251 119 665
ADAPT 19" 1U3 ETSI 21E1 BNC/75 A155 251 035 468
CARTES
ADR IC1.1 CTE ITFE STM1 OPTIQ IC1.1 FC/PC NR A155 251 137 366
ADR IC1.2 CTE ITFE STM1 OPTIQ IC1.2 FC/PC NR A155 251 137 379
ADR MM1 CTE ITFE STM1 OPTIQ MM1 SC/PC NR A155 251 050 639
ADR S1.1 CTE ITFE STM1 OPTIQ S1.1 SC/PC NR A155 251 137 387
ADR L1.1 CTE ITFE STM1 OPTIQ L1.1 SC/PC NR A155 251 137 390
ADR S4.1 CTE ITFE STM4 OPTIQ S4.1 SC/PC NR A155 251 128 619
ADR L4.1 CTE ITFE STM4 OPTIQ L4.1 SC/PC NR A155 251 128 627
ADR L4.2 CTE ITFE STM4 OPTIQ L4.2 SC/PC NR A155 251 172 592
ADR ERE CTE ITFE STM1 ELEC BNC NR A155 251 137 431
ADRLAN1 CTE ITFE ETH 10/100BT ADRLAN NR A155 251 137 410
ADR21E1R8 CTE ITFE 21E1/ 8E1 RET /120NR A155 251 259 985
ADRIMA CTE ITFE ETH 10/100BT ADRIMA NR A155 251 229 007
ADRGFP150 CTE ITFE ETH 10/100 BT ADRGFP NR ADR155 251 347 772
Boîtier externe
Accès MNGT
Cordon pour interface de gestion entre deux 3m 55 670 656
ADR 155C
Cordon d'adaptation 9 points / 15 points pour 2,5 m 251 025 855
X24/V11 5m 251 025 876
Accès COMM
Accès de gestion VT100 1,8 m 4 980 214
Accès ETH
Accès Ethernet sur carte-mère ou module
ADRLAN1, ADRIMA, ADRGFP150: câble UTP
catégorie 5
3m 55 670 422
Cordon droit mâle – mâle * 3m 55 670 610
Cordon croisé mâle – mâle **
Accès LOOPS
Boucles d'alarmes GTR et télésignalisation 2,5 m 6 013 628
(1/2 cordon) 12 m 6 013 161
Accès POWER Energie
Cordon extrémité libre 3m 251 065 817
Cordon PAPA 3m 55 670 797
Accès TR ou REC (cartes ADR IC1.1, IC1.2) 2,5 m 6 491 366
3,4 m 6 491 367
Jarretière optique FC-PC/FC-PC 5,8 m 6 491 369
7m 6 491 370
8,2 m 6 491 371
9,4 m 6 491 372
15 m 55 670 481
20 m 55 670 495
25 m 55 670 752
4. CARACTERISTIQUES TECHNIQUES
EQUIPEMENT
Caractéristiques optiques
Type d'interface IC1.1 = L1.1 + S1.1; IC1.2 = L1.2 + S1.2; MM1; S1.1;
L1.1 ; S4.1; L4.1; L4.2
Débit STM-1 :155,520 Mbit/s ± 20 ppm
STM-4 : 622,08 Mbit/s ± 20 ppm
Norme UIT-T G.957 pour interface monomode
ANSI T1.646 (MM1) pour interface multimode
Codage Non codé (NRZ)
Fibre optique monomode : 1310 nm (IC1.1, S1.1, L1.1, S4.1, L4.1) ou
1550 nm (IC1.2, L4.2),
ou multimode : 1310 nm (MM1)
UIT-T G.652.
Atténuation garantie IC1.1, IC1.2 : 0 - 28 dB sans atténuateur externe
L1.1 : 10 – 28 dB
S1.1 : 0 – 12 dB
MM1 : 0 – 4 dB
L4.1, L4.2 : 10 - 24dB
S4.1 : 0 - 12dB
Portée typique S1.1 : 0 – 15 km
IC1.1 : 0 – 40 km
L1.1 : 10 – 40 kmIC1.2 : 0 – 80 km
MM1 : 0 – 2 km
S4.1 : 0 - 15km
L4.1 : 10 - 40km
L4.2 : 10 - 80km
Connecteur IC1.1, IC1.2 : FC/PC ou SC/PC
L1.1, S1.1, MM1, S4.1, L4.1, L4.2 : SC/PC
Caractéristiques mécaniques du châssis ADR 155c
Hauteur 2U
Largeur 19" ou ETSI
Profondeur 257 mm en baie 19''
243 mm en baie ETSI
Masse environ 6 kg
Indice de Protection (IP) correspond à l'IP de la baie utilisée
Caractéristiques mécaniques du bandeau 75Ω
Hauteur 1.3U
Largeur 19" ou ETSI
Profondeur 75mm
Consommation < 40 W (pour un châssis équipé de
(voir détails ci-après) deux cartes ADR Optique et deux cartes ADR LAN1)
EQUIPEMENT
Caractéristiques d'environnement
Mécaniques ETS 300 119-4 (19") ou CEI 297-3 (ETSI)
ETS 300 019-2-3
Condition climatique CEI 721-1 (1993)
ETS300 019 part 1-3, class 3.1, 3.2
Température de fonctionnement - 5 °C à + 45°C
Température de fonctionnement - 5 °C à + 55°C (le MTBF [Mean Time Between
étendue Failure] est sensiblement dégradé)
Température de transport et de - 40°C à + 70°C
stockage
Humidité relative < 85%
CEM (Compatibilité Electro-
EN 300386
Magnétique) et DES
Sécurité NF EN 60950-1 Avril 2002
(l'équipement n'est pas enceinte au feu)
Energie ETS 300132-2
(l'équipement est TBTS)
(*)
Fiabilité prévisionnelle
-6
Carte mère 1,12 10
-6
Carte ADR21E120 0,29 10
-6
Carte ADR21E1R8 0,43 10
-6
Carte ADRIC1.1 (FC/PC) 1,5 10
-6
Carte ADRIC1.2 (FC/PC) 1,5 10
-6
Carte ADRMM1 0,96 10
-6
Carte ADRL1.1 0,96 10
-6
Carte ADRS1.1 0,96 10
-6
Carte ADRERE 0,29 10
-6
Carte ADRE3DS3 0,21 10
-6
Carte ADRLAN 0,52 10
-6
Carte ADRIMA 0,54 10
-6
Carte ADRGFP150 0,77 10
(2) -6
Carte ADRS4.1 1,1 10
(2) -6
Carte ADRL4.1 1,1 10
(2) -6
Carte ADRL4.2 1,1 10
-6
Fond de panier 0,25 10
-6
Alimentation 0,39 10
-6
Module ADR FAN 3 10
*
Consommation par organe (mesurée sur alimentation 48V)
Carte-mère 11,3 W
Carte ADR21E120 5,0 W
Carte ADRIC1.x 4,7 W
Carte ADRMM1 3,7 W
Carte ADRL1.1 3,7 W
Carte ADRS1.1 3,7 W
Carte ADRERE 4,9 W
Carte ADRE3DS3 (en mode DS3) 3,9 W
Carte ADRE3DS3 (en mode E3) 3,72 W
Carte ADRLAN 6,8 W
Carte ADRIMA 5,9W
Carte ADRGFP150 11W
Carte ADRS4.1 4,0W
Carte ADRL4.1 4,0W
Carte ADRL4.2 4,0W
Carte ADR21E1R8 5,5 W
Module ADRFAN 4,43 W
* Ces consommations sont des valeurs typiques et peuvent servir pour l'évaluation de la
dissipation. Il convient d'ajouter 20% pour estimer les valeurs crêtes qui régissent le
dimensionnement des ateliers d'énergie. Ceci permet de tenir compte des variations
transitoires de consommation et des variations de rendement du convertisseur en fonction de
la puissance totale.
Attention : Il convient d'ajouter une majoration supplémentaire de 10% en cas d'alimentation
sous 72V.
Introduction
Vous venez d'acquérir un équipement ADR155c et nous vous en remercions.
L'équipement est livré avec une procédure de démarrage pour vous aider à partir d'exemples, à le configurer en fonction de la topologie du réseau à
construire.
a) Déballer l'équipement
b) Insérer puis visser les cartes dans les alvéoles utilisées
c) Raccorder le cordon d'énergie puis alimenter l'équipement
d) Après quelques secondes, vérifier que la led verte « ON » est allumée fixe sur l'équipement
Caractéristiques minimales du PC
Mémoire 32 Mo 64 Mo 128 Mo
(*) Le PC d'exploitation peut être équipé de Internet Explorer 5.5 ou 6.0 (version livrée avec Windows XP)
1
Marque déposée Microsoft Corporation
Guide d'Installation et d'Utilisation – N56717020107
Page B5-2 Reproduction et communication interdites sans autorisation écrite de SAGEM SA
5 – GUIDE DE DEMARRAGE
Pour être exploité, le châssis ADR155c doit avoir l'adresse Equipement ainsi que l'adresse du port Ethernet configurées dans deux sous-réseaux
différents.
La configuration de l'adresse Equipement et celle du port Ethernet est réalisée à l’aide de l’application HyperTerminal de Windows.
Ø Raccorder l’accès "COMM" de l’équipement à un port "COM" non utilisé du PC à l'aide du cordon Cordon droit SUB-D 9pts Mâle / Femelle
Ø Mettre le PC sous tension
Ø Windows étant démarré, lancer l'application HyperTerminal
( Menus : Démarrer / Programmes / Accessoires / HyperTerminal )
Ø Donner un nom et choisir une icône pour la connexion puis valider les choix
Ø Choisir le port "COM" du PC qui est raccordé à l'équipement puis valider le choix
Ø Configurer les paramètres du port suivant les caractéristiques ci-dessous puis valider la programmation
• Bits par seconde : 19200
• Bits de données : 8
• Parité : Aucun
• Bits d'arrêt : 1
• Contrôle de flux : Aucun
. Enregistrer la configuration de la connexion. Lors de la prochaine ouverture de l'application HyperTerminal, il suffira de choisir l'icône de
la connexion pour se connecter à l'équipement.
Ø Appuyer deux fois sur la touche "ENTER" du clavier.
La fenêtre MAIN MENU apparaît à l'écran.
L'adresse Equipement sera utilisée pour la notification des alarmes et évènements au Gestionnaire. Cette adresse est obligatoire lors de l'utilisation des
liens PPP Unnumbered ( Dans l'exemple ci-dessous, l'adresse Equipement est 192.168.30.30 ).
Choisir le menu 1
et valider en
appuyant sur la
touche "ENTER"
du clavier.
Répondre aux
questions et valider
chaque réponse en
appuyant sur la
touche "ENTER"
du clavier.
Dans l'exemple ci-
contre, l'adresse
Equipement est
192.168.30.30
: Valeurs à saisir
L'adresse de ce port doit se situer dans le même réseau que celle de l'interface Ethernet du PC ( Dans l'exemple ci-dessous, l'adresse de sous-réseau est
135.11.110.8 et le masque de sous-réseau est 255.255.255.252 ).
NOTA : Avec Windows 9x, l'adresse du PC se visualise en sélectionnant ( avec le bouton droit de la souris ) Propriétés de l'icône Voisinage Réseau puis
( avec le bouton gauche de la souris ) Propriétés du composant TCP/IP ( TCP/IP -> "Nom de la Carte Réseau" ).
Avec Windows NT, l'adresse du PC se visualise en sélectionnant ( avec le bouton droit de la souris ) Propriétés de l'icône Voisinage Réseau puis
( avec le bouton gauche de la souris ) Propriétés du composant TCP/IP ( Protocole TCP/IP ).
Avec Windows 2000/XP, l'adresse du PC se visualise en sélectionnant ( avec le bouton droit de la souris ) Propriétés de l'icône Favoris Réseau
puis Propriétés de l'icône Connexion au réseau local suivi de ( avec le bouton gauche de la souris ) Propriétés du composant TCP/IP
( Protocole Internet (TCP/IP) ).
Choisir le menu 2
et valider en
appuyant sur la
touche "ENTER"
du clavier.
Répondre aux
questions et valider
chaque réponse en
appuyant sur la
touche "ENTER"
du clavier.
Dans l'exemple ci-
contre, l'adresse
du port Ethernet
de l'équipement est
135.11.110.10
: Valeurs à saisir
Exploitation de l'équipement
Exemple :
Pour pouvoir exploiter l'équipement, consulter le menu d'aide en cliquant sur le lien Help de la fenêtre principale.
La configuration d'un port PPP (Point to Point Protocol) d'un équipement est nécessaire lors de l'extension d'un réseau et est réalisée, comme pour la
modification de l’adresse Equipement et du port Ethernet, à l’aide du Navigateur HTTP.
Dans l'exemple ci-dessous, les indications sont données pour la configuration du port PPP1. La configuration des ports PPP2, PPP3 et PPP4 est
identique à celle du port PPP1.
Ø Raccorder l’accès "ETH" de l’équipement à la carte Ethernet du PC à l'aide du cordon Ethernet croisé RJ45
. La led jaune du connecteur "ETH" de l'équipement doit s'allumer.
Ø Lancer le Navigateur HTTP
Ø Dans l'écran d'accueil, renseigner le champ "Adresse" avec l'adresse Equipement (192.168.30.30)
Ø La fenêtre Welcome on the ADR155C's site apparaît à l'écran. Par défaut, il n'y a pas de Mot de Passe; cliquer sur le bouton "Apply"
Ø La fenêtre Shelf view apparaît à l'écran.
Ø Cliquer sur le port "ETH" puis sur le lien "Interfaces Configuration" pour configurer le port PPP1 de l'équipement.
Ø Cliquer sur le lien "Routing Table" pour visualiser la configuration de routage de l'équipement
Exemple :
Ce chapitre décrit à l'aide d'un exemple la configuration IP des interfaces pour une liaison point à point.
Pour chaque équipement, il est possible de configurer le port Ethernet, l'adresse Equipement et quatre ports logiciel PPP (Point to Point Protocol) de
PPP1 à PPP4. A chaque port logiciel PPP, il est possible d'affecter un des cinq ports physiques correspondant au port MNGT et aux alvéoles A, B, C, D ainsi que
deux canaux VC12 repérés P#1 et P#2.
Exemple :
Ø Se reporter au chapitre Se connecter
à un ADR155c pour configurer le port
Ethernet et l'adresse Equipement de
chaque châssis.
Ø Se reporter au chapitre Configurer un
port PPP pour configurer les ports
PPP de chaque équipement.
Ø Les deux équipements ADR155c sont exploitables à l'aide d'un Navigateur HTTP.
Ø Se reporter au chapitre Se connecter à un ADR155c pour l'exploitation des équipements avec le Navigateur HTTP.
Ce chapitre décrit à l'aide d'un exemple la configuration IP des interfaces pour une liaison en bus.
Pour chaque équipement, il est possible de configurer le port Ethernet, l'adresse Equipement et quatre ports logiciel PPP (Point to Point Protocol) de
PPP1 à PPP4. A chaque port logiciel PPP, il est possible d'affecter un des cinq ports physiques correspondant au port MNGT et aux alvéoles A, B, C, D ainsi que
deux canaux VC12 repérés P#1 et P#2.
Exemple :
Ø Les trois équipements ADR155c sont exploitables à l'aide d'un Navigateur HTTP.
Ø Se reporter au chapitre Se connecter à un ADR155c pour l'exploitation des équipements avec le Navigateur HTTP.
Ce chapitre décrit à l'aide d'un exemple la configuration IP des interfaces pour un réseau en anneau.
Pour chaque équipement, il est possible de configurer le port Ethernet, l'adresse Equipement et quatre ports logiciel PPP (Point to Point Protocol) de
PPP1 à PPP4. A chaque port logiciel PPP, il est possible d'affecter un des cinq ports physiques correspondant au port MNGT et aux alvéoles A, B, C, D ainsi que
deux canaux VC12 repérés P#1 et P#2.
Exemple :
Ø Les trois équipements ADR155c sont exploitables à l'aide d'un Navigateur HTTP. Les liens de gestion sont sécurisés grâce au protocole OSPF.
Ø Se reporter au chapitre Se connecter à un ADR155c pour l'exploitation des équipements avec le Navigateur HTTP.
Ce chapitre décrit à l'aide d'un exemple la configuration IP des interfaces pour un réseau dont les liens de gestion transitent au travers d'équipements
de constructeur différent.
Pour chaque équipement, il est possible de configurer le port Ethernet, l'adresse Equipement et quatre ports logiciel PPP (Point to Point Protocol) de
PPP1 à PPP4. A chaque port logiciel PPP, il est possible d'affecter un des cinq ports physiques correspondant au port MNGT et aux alvéoles A, B, C, D ainsi que
deux canaux VC12 repérés P#1 et P#2.
Exemple :
Précisions pour la configuration du port PPP3 de l'ADR155c N°3 et du port PPP1 de l'ADR155c N°4
Cette annexe décrit d’une façon succincte les règles permettant de construire un RGT basé sur
la suite de protocoles IP.
A.1 - Préambule
Le réseau de gestion de l’ADR155c s’appuie sur la pile de protocole IP. Chaque nœud de
réseau (chaque ADR155c) intègre un routeur IP qui route chaque paquet vers sa destination ;
ces nœuds du réseau sont reliés entre eux par des liens PPP ( Point to Point protocol).
Les routes statiques telles qu’elles sont implémentées dans l’ADR155c ont les caractéristiques
suivantes :
• à une route est attribuée une métrique.
• à une route est attribuée une préférence. La préférence sert à régler les conflits quand des
routes de types différents (statiques et dynamiques) ont même destination.
• la préférence a été accordée aux routes statiques par rapport aux routes dynamiques.
• les routes statiques sont toujours exportées par les protocoles de routage aux autres
équipements
Selon l’état opérationnel ou non de l’interface qu’elles empruntent les routes statiques sont
mises en place ou enlevées évitant ainsi qu’elle imposent des routes non valides.
Un maximum de vingt routes statiques est supporté par chaque ADR.
La figure suivante donne un exemple de réseau IP et des tables de routage associé à deux
équipements types. On note que chaque port de la fonction de routage embarquée correspond
à un SUBNET différent.
140.1.1.3
F3
140.1.0.2 140.1.0.3 140.1.1.2
Gestionnaire Fibre 140.1.1.4
F1 F2
128.1.0.1 Ethernet
128.1.0.2 F4
Ethernet 140.1.1.5
NET 128.1 128.1.0.3
NET 140 - 1 F5
F6
PPP1 150.1.0.2
Fibre Fibre
150.1.0.3
F7
150.1.1.2
Ethernet Ethernet
Configuration de l'ADR155C F6
Interfaces
Eth 128.1.0.3
Masque de sous réseau 255.255.0.0
PPP1 150.1.0.2
Masque de sous réseau 255.255.255.0
Routes statiques
Dest @IP Subnet mask Next hop Interface Metric Remarque
Configuration de l'ADR155C F8
Interfaces
Eth 150.1.1.3
Masque de sous réseau 255.255.255.0
Routes statiques
Dest @IP Subnet mask Next hop Interface Metric Remarque
A.2.2.1 Réseau 1
Ce réseau est le cas le plus simple d’un réseau d’équipements ( à partir du palier P3.1) tous
reliés par des liens PPP unnumbered.
ppp Unn
ADR 2
ppp Unn
ppp Unn
ppp Unn
ADR 3
ADR 1
s/s réseau
ppp Unn
éthernet
Ethernet
Un protocole de routage RIP ou OSPF est mis en œuvre, (RIP uniquement si la dimension du
réseau le permet).
Le réseau Ethernet constitue un sous réseau IP, l’interface Ethernet se voit affecter une adresse
dans ce sous réseau.
Les adresses des équipements (c’est-à-dire l’adresse équipement) peuvent être choisis de
manière quelconque, mais pas dans le sous réseau Ethernet.
Le décompte du nombre d’adresses par équipement donne :
L’ADR 1 a deux adresses (adresse Ethernet et adresse équipement), les ADR 2 et 3 ont chacun
une adresse (l’adresse équipement).
A.2.2.2 Réseau 2
Ce réseau comporte des ADR ( à partir du palier P3.1) ainsi que un équipement palier P1 ou
P2.
s/s réseau 3
ppp Num 3 ADR 4
ADR 2
ppp Unn
FOTC 1 ppp Unn ppp Num 2
ADR 3
ADR 1
s/s réseau 1 ppp Unn
Ethernet
Les liens PPP reliant respectivement l’ ADR 4 et les ADR 2 et ADR3 doivent être de type
numéroté. Les liens PPP entre ADR1,ADR2,ADR3 seront préférentiellement de type
unnumbered.
Pour outrepasser les contraintes de RIP ( limite à 16 « bonds »), on peut scinder le réseau en 2
domaine de routage selon le schéma suivant :
Domaine 2
ADR 2
Domaine 1
ADR 1
ADR 0
Ethernet
Le lien entre les 2 ADR de bordure peut être de type Ethernet, PPP numéroté ou PPP
unnumbered.
RIP n’est pas activé sur les interfaces de ce lien de raccord entre les 2 domaines.
Le routage entre les deux domaines est rendu possible par des routes statiques configurées
dans ces ADR.
L’ADR 1 doit posséder des routes statiques vers les sous réseaux qui constituent le domaine 2
et l’ADR 2 des routes vers les sous réseaux qui constituent le domaine 1.
Les routes statiques vers les sous réseaux d’un domaine (2 par exemple) dans l’ADR de
bordure de l’autre domaine (ADR 1) peuvent être réduites à une seule route vers un sous
réseau agrégeant les sous réseaux du domaine (2)
Ce sous réseau englobant doit être distinct des sous réseaux de l’autre domaine (1 dans
l’exemple).
UN SEUL Email :
ON A SINGLE Email address:
[email protected]