A B C D E F: C/C of Beam C/C of Beam C/C of Beam C/C of Beam C/C of Beam

The document appears to be an engineering drawing showing dimensions and details of beam reinforcements. It includes 6 labeled sections with dimensions for the center-to-center spacing of beams and sizes of concrete beams. Notes provide specifications for the grade of concrete and reinforcement, required concrete cover thickness, lap lengths, and standards to be followed for bending and fixing reinforcements.

Uploaded by

PinapaSrikanth
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views

A B C D E F: C/C of Beam C/C of Beam C/C of Beam C/C of Beam C/C of Beam

The document appears to be an engineering drawing showing dimensions and details of beam reinforcements. It includes 6 labeled sections with dimensions for the center-to-center spacing of beams and sizes of concrete beams. Notes provide specifications for the grade of concrete and reinforcement, required concrete cover thickness, lap lengths, and standards to be followed for bending and fixing reinforcements.

Uploaded by

PinapaSrikanth
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Fold-2

Fold-1

Fold-2
6 5 4 3 2 1

DRAWING NO.:

A B C D E F
F F

2670 2110 2670 3890 3890


C/C OF BEAM C/C OF BEAM C/C OF BEAM C/C OF BEAM C/C OF BEAM
NOTES

1. ALL DIMENSIONS ARE IN MM


2. NO DIMENSIONS FROM THIS DRAWING ARE TO BE
SCALED OFF AND ONLY FIGURED DIMENSIONS SHALL
BE FOLLOWED
300 X 450 300 X 450 300 X 450 300 X 450 300 X 450
2000

2250

1650

1650

1450
3. GRADE OF CONCRETE SHALL BE M 30
Fold-4 1 4. ALL REINFORCEMENT SHALL BE OF GRADE FE500
Fold-4
C1/F3 C2/F4 C2/F2 C1/F2 C1/F1
CONFORMING TO IS:1786-1985
E E
C/C OF BEAM

1450 5. CLEAR COVER TO REINFORCEMENT SHALL BE 40 MM


1650 1650
2670

2000 2250 6. LAP LENGTH AND ANCHORAGE LENGTH SHALL BE 57


TIMES THE BAR DIAMETER
7. BENDING AND FIXING OF REINFORCEMENT SHALL BE
375 X 300 375 X 300 375 X 230 375 X 300 375 X 300 AS PER IS:2502-1963
2250

2650

2650

2000
1450
2
C2/F4 C3/F7 C3/F1 C2/F6 C2/F3

1450
2250 2000
C/C OF BEAM

2650 2650
3890

D 1750 D

300 X 450 300 X 450 300 X 450 300 X 450 300 X 450 300 X 450
2250

2250
2900

2650

2400
2650
2400

Fold-3
3 Fold-3

C2/F5 C2/F6 C1/F7 C2/F5


C1/F4 C2/F4-1
C/C OF BEAM
2440

2250 2400 2400


2650 2650
C 230 X 375 230 X 375 375 X 300 375 X 300 C
1450

1450

1650

1650
4
C4/F1 C4/F1 C5/F2 C5/F2

1450 1450 1650 1650


C/C OF BEAM
3890

EXECUTIVE ENGINEER
APEWIDC, KRISHNA DT.

B 300 X 450 300 X 450 300 X 450 300 X 450 300 X 450 300 X 450
2000

2000

2000

2400

2400

2000
Fold-4
5 Fold-4

C1/F3 C6/F3 C6/F3 C6/F5 C1/F5 C1/F3


DEPT. NAME SIGN DATE

AQUA LAB
CODE DRN

2000 2000 2000 2000


2400 2400 DESN

MACHILIPATNAM CHD

REV. DATE ALTD CHD APPD REV. DATE ALTD CHD APPD REV. DATE ALTD CHD APPD REV. DATE ALTD CHD APPD
APPD

TITLE:

FOUNDATION LAYOUT - I
A

DRAWING NO. :

DEPT.

SIGN

8 7 6 5 4 3 DATE SHEET OF REV.


Fold-2

Fold-1

Fold-2