0% found this document useful (0 votes)
76 views3 pages

SIMATIC S7 - 200 Micro PLC: General

This document provides specifications for discrete I/O, analog I/O, and relay output modules for the SIMATIC S7-200 Micro PLC system. Key specifications outlined include input/output types, voltage ranges, current limits, isolation capabilities, and component lifetime ratings. Analog modules allow for measuring voltage and current changes with 12-bit resolution, and consume between 20-30mA of power.

Uploaded by

Dharmil Bhavsar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
76 views3 pages

SIMATIC S7 - 200 Micro PLC: General

This document provides specifications for discrete I/O, analog I/O, and relay output modules for the SIMATIC S7-200 Micro PLC system. Key specifications outlined include input/output types, voltage ranges, current limits, isolation capabilities, and component lifetime ratings. Analog modules allow for measuring voltage and current changes with 12-bit resolution, and consume between 20-30mA of power.

Uploaded by

Dharmil Bhavsar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

16_Sec (161-180).

qxd 07/28/03 03:38 PM Page 16/168

SIMATIC S7 - 200 Micro PLC


General
EM 221, 222, 223
■ Discrete I/O module specifications
There are a wide range of discrete input, discrete output, and discrete combination expansion modules available in the S7-200 Micro PLC
family. Regardless of the combination of points, the modules all share the same basic characteristics.

AC input features DC input features


Input type IEC Type 1 Input type Sink/Source (IEC Type 1 sink)
Input Voltage Input Voltage
Maximum continuous 264 VAC Maximum continuous 30 VDC
Surge - Surge 35 VDC for 0.5 s
Rated value 120 VAC at 6 mA or 230 VAC at 9 mA, nominal Rated value 24 VDC at 4 mA, nominal
Logic 1 signal (minimum) 79 VAC at 2.5 mA, minimum Logic 1 signal (minimum) 15 VDC at 2.5 mA, minimum
Logic 0 signal (maximum) 20 VAC at 1 mA, AC Logic 0 signal (maximum) 5 VDC at 1 mA, maximum
Isolation (Field Side to Logic) 1500 VAC for 1 min Isolation (Field Side to Logic) Optical (galvanic), 500 VAC for 1 min
Input Delay Times 15 ms Input Delay Times 4.5 ms
2-Wire Prox. Leakage 1 mA, AC 2-Wire Prox. Leakage 1 mA, maximum

■ Discrete output module specifications


Output specifications DC output Relay output Output specifications DC output Relay output
General Number of Outputs 4 4
Output Type Solid State-MOS- Relay, dry contact General
Permissible range FET 5 - 30VDC or 5 - Output Type Solid State-MOS- Relay, dry contact
20.4 to 28.8 VDC 250VAC Permissible range FET 12 - 30VDC or 12 -
Rated value - 20.4 to 28.8 VDC 250 VAC
Logic 1 signal at max. current 24 VDC - Rated value -
Logic 0 signal with 10 K Ω load 20 VDC, minimum - Logic 1 signal at max. current 24 VDC -
0.1 VDC, maximum Logic 0 signal with 10 K Ω load 20 VDC, minimum -
0.2 VDC, maximum
Output current Output Current
Logic 1 signal 0.75 A 2.00 A Logic 1 signal 0.75 A 10.00 A
Max. current per common/group 3A 8A Max. current per common/group 3A 10A
Lamp load 5.0 W 30 W DC/200 W AC Lamp load 5.0 W 100 W DC/1000 W
ON state resistance (contact) 0.3 Ω 0.2 Ω, max when new ON state resistance (contact) 0.3 Ω AC
Leakage current per point 10 µA, maximum - Leakage current per point 10 µA, maximum 0.1 Ω, max when new
Surge current 8 A for 100 ms, max 7 A w/ contacts closed Surge current 30 A -
Overload protection 15 A for 4s@10%
duty cycle
Overload protection No No No No

Isolation Isolation
Optical isolation (galvanic) 500 VAC for 1 min - Optical isolation (galvanic) 500 VAC for 1 min -
Isolation resistance - 100 M Ω, min when new Isolation resistance - 100 M Ω, min.
when new

Isolation coil to contact - 1500 VAC for 1 min Isolation coil to contact - 1500 VAC for 1 min
Isolation between open contacts - 750 VAC for 1 minute Isolation between open contacts - 750 VAC for 1 min
Inductive Load Clamping Inductive Load Clamping
Repetitive Energy dissipation < 1 W, all channels - Repetitive Energy dissipation < 1 W, all channels -
0.5 LI2 x switch. rate 0.5 LI2 x switch. rate
Clamp voltage limits L+ minus 48 V - Clamp voltage limits L+ minus 48 V -
Output Delay Output Delay
Off to On 50 µs, max. - Off to On 50 µs, max. -
On to Off 200 µs, max. - On to Off 200 µs, max. -
Relay Life Relay Life
Switching delayLifetime - 10 ms,maximum Switching delayLifetime - 10 ms, maximum
mechanical (no load) - 10,000,000 open/close mechanical (no load) - 30,000,000 open/
close

Lifetime contacts at rated load - 100,.000 open/close Lifetime contacts at rated Load - 30,.000 open/close

16/168 Siemens Energy & Automation, Inc.


Industrial Controls Catalog
16_Sec (161-180).qxd 07/28/03 03:38 PM Page 16/169

SIMATIC S7 - 200 Micro PLC


General
EM 231, 232, 235

■ Analog I/O module specifications


Analog I/O modules are used in a wide variety of applications to measure current or voltage changes.

Description EM 231 AI4 x 12 Bit EM 232 AQ2 x 12 Bit EM 235 AI4/AQ1 x 12 Bit
General specifications
Power Consumption
From +5 VDC (I/O bus) 20 mA 20 mA 30 mA
From L+ 60 mA 70 mA (both outputs at 20 mA) 60 mA (with output at 20 mA)
L+ voltage range, Class 2 or DC 20.4 to 28.8 20.4 to 28. 20.4 to 28.8
sensor supply
LED indicator 24 VDC Power Supply Good 24 VDC Power Supply Good, 24 VDC Power Supply Good,
ON = no fault, ON = no fault, ON = no fault,
OFF = no 24 VDC power OFF = no 24 VDC power OFF = no 24 VDC power

Analog input specifications


Data word format
Bipolar, full-scale range -32000 to +32000 -32000 to +32000
Unipolar, full-scale range 0 to 32000 0 to 32000
Input impedance ≥10 MΩ ≥10 MΩ
Input filter attenuation -3 db @ 3.1 Khz -3 db @ 3.1 Khz
Maximum input voltage 30 VDC 30 VDC
Maximum input current 32 mA 32 mA
Resolution 12 bit A/D converter 12 bit A/D converter
No. of Analog Input Points 4 4
Isolation (Field side to logic) None None
Input type Differential Differential
Input ranges 0 to 10 V, 0 to 5 V,
Voltage (unipolar) 0 to 10 V, 0 to 5 V 0 to 1 V, 0 to 500 mV,
0 to 100 mV, 0 to 50 mV
± 10 V, ± 5 V, ± 2.5 V,
Voltage (bipolar) ±5 V, ± 2.5 V ± 1 V, ± 500 mV,
± 250 mV, ± 100 mV,
± 50 mV, ± 25 mV
Current 0 to 20 mA 0 to 20 mA
Analog to digital conv. time < 250 ∝s < 250 ∝s
Analog input step esponse 1.5 ms to 95% 1.5 ms to 95%
Common mode rejection 40 dB, DC to 60 Hz 40 dB, DC to 60 Hz
Common mode voltage Signal voltage plus Signal voltage plus
common mode voltage common mode voltage
(must be ≤ 12 V) (must be ≤ 12 V)

Analog output specifications


Isolation (Field side to logic) None None
Signal range
Voltage output ± 10 V ± 10 V
Current output 0 to 20 mA 0 to 20 mA
Resolution, full-scale
Voltage 12 bits 12 bits
Current 11 bits 11 bits
Data word format
Voltage -32000 to +32000 -32000
Current 0 to +32000 0 to +32000
Accuracy
Worst case, 0° to 55° C
Voltage output ± 2% of full-scale ± 2% full scale
Current output ± 2% of full-scale ± 2% full scale
Typical, 25° C
Voltage output ± 0.5% of full-scale ± 0.5% full scale
Current output ± 0.5% of full-scale ± 0.5% full scale
Settling time
Voltage output 100 µS 100 µS
Current output 2 mS 2 mS
Maximum drive
Voltage output 5000 Ω min. 5000 Ω min.
Current output 500 Ω max. 500 Ω max.

Siemens Energy & Automation, Inc. 16/169


Industrial Controls Catalog
16_Sec (161-180).qxd 07/28/03 03:38 PM Page 16/170

SIMATIC S7 - 200 Micro PLC


General
EM 231 modules

■ RTD & thermocouple module specifications ■ Thermocouple module ■ RTD module


The RTD & Thermocouple modules are most The EM 231 Thermocouple module provides a The EM 231 RTD module pro-
often used in applications involving tempera- convenient, isolated interface for the S7-200 family vides a convenient interface
ture control. to seven thermocouple types: J, K, E, N, S, T, and for the S7-200 family to sever-
R. It also allows the S7-200 monitor low level ana- al different RTDs. It also allows
log signals, in the 80mV range. The module has the S7-200 to measure three
DIP switches to select the thermocouple type, different resistance ranges.
open wire check, temperature scale, cold junction You use DIP switches to select
compensation and burnout direction. All thermo- RTD type, wiring configura-
couples attached to the module must be of the tion, temperature scale, and
same type. The EM 231 Thermocouple module can burnout direction. Both RTDs
report temperatures in Celsius or Fahrenheit. attached to the module must
be of the same type

Description EM 231 AI4 x Thermocouple EM 231 AI2 x RTD


General specifications
Power Consumption
From +5 VDC (I/O bus) 87 mA 87 mA
From L+ 60 mA 60 mA
L+ voltage range, Class 2 or DC sensor supply 20.4 to 28.8 VDC 20.4 to 28.8 VDC
LED indicator 24 VDC Power Supply Good 24 VDC Power Supply Good
ON = no fault ON = no fault
OFF = no 24 VDC power OFF = no 24 VDC power
SF SF
ON = module failure ON = module failure
BLINKING = input signal error BLINKING = input signal error
OFF = no faults OFF = no faults

Analog input specifications


Isolation
Field side to logic 500 VAC 500 VAC
Field side to 24 VDC 500 VAC 500 VAC
24 VDC to logic 500 VAC 500 VAC
Common mode input range 120 VAC (input channel to channel) 0
Common mode rejection > 120 dB @ 120 VAC > 120 dB @ 120 VAC
Input type Floating TC Module ground referenced RTD
Input ranges TC types (select one): S, T, R, E, N, K, J RTD types (select one):
Voltage range: +/- 80 mV Pt -100Ω, 200Ω, 500W, 1000Ω
(with a = 3850 ppm, 3920 ppm,
3850.55 ppm, 3916 ppm, 3902 ppm)
Pt -10000Ω (a = 3850 ppm)
Cu -9.035Ω (a = 4720 ppm)
Ni -10Ω, 120Ω, 1000Ω
(with a = 6720 ppm, 6178 ppm)
R -150Ω, 300Ω, 600Ω FS
Input Resolution
Temperature 0.1° C / 0.1° F 0.1° C / 0.1° F
Voltage 15 bits plus sign
Resistance 15 bits plus sign
Measuring Principle Sigma-delta Sigma-delta
Module update time: All ch. 405 mS 405 mS (700 ms for Pt10000)
Wire length 100 meters to sensor max 100 meters to sensor max
Wire loop resistance 100W max 20Ω, 2.7Ω for CU max
Suppression of interference 85 dB @ 50 Hz/60 Hz/ 400 Hz 85 dB @ 50 Hz/60 Hz/ 400 Hz
Data word format Voltage: -27648 to + 27648 Resistance: -27648 to + 27648
Maximum sensor dis. 1m W
Input impedance >1 MΩ >10 MΩ
Maximum input voltage 30 VDC 30 VDC (sense), 5 VDC (source)
Resolution 15 bit + sign 15 bit + sign
Input filter attenuation -3 dB @ 21 kHZ -3 dB @ 3.6 kHZ
Basic error 0.1% FS (voltage) 0.1% FS (resistance)
Repeatability 0.05% FS 0.05% FS
Cold junction error ±1.5 ° C