Pier Wall Design Specifications

The document provides design parameters and calculations for the design of a pier wall. Key parameters include a concrete compressive strength of 3000 psi, rebar yield strength of 60000 psi, and maximum flood elevation of 10 meters. Calculations are shown for checking wall thickness, shear capacity, flexural reinforcement, and developing a final reinforcement layout. The layout includes #16mm rebar spaced at 150mm along the weak section and 200mm elsewhere.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
356 views5 pages

Pier Wall Design Specifications

The document provides design parameters and calculations for the design of a pier wall. Key parameters include a concrete compressive strength of 3000 psi, rebar yield strength of 60000 psi, and maximum flood elevation of 10 meters. Calculations are shown for checking wall thickness, shear capacity, flexural reinforcement, and developing a final reinforcement layout. The layout includes #16mm rebar spaced at 150mm along the weak section and 200mm elsewhere.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

DESIGN OF PIER WALL

PARAMETERS:
f'c = 3000 psi = 20.73 Mpa Hw= 11 m 433.071
fy = 60000 psi = 414.7 Mpa h= 0.6 m 23.622
µ= 0.5 Lw= 20 m 787.402
ca= 0.32 Ht. of dam crest= 7 m 275.591
δconc.= 23.5 Kn/m3 Max. Elev. Of flood= 10 m 393.701
width of gate= 2.2 m 86.614
d= 16 m 629.921
Nu= 5 Kip

HORIZONTAL FORCES
CASE DL (kip) DL2(Kip) LL(Kip) TOTAL (Kip)
NORMAL CONDITION 32.393 118.776 151.169
MAX. FLOOD 66.109 242.4 25 333.509

CHECK FOR THICKNESS:


Vu= 333.509

Vn=
Vn= 6112.581 Kip > 333.509 (OK)

CHECK FOR SHEAR:


Vc=

Vc= 2689.536 Kip

Vc= Mu= 15865.76 Kip-f

Vc= 5016846.375 Kip

CHECK FOR SHEAR REINFORCEMENT:

1008.576 Kip > 333.509 Kn

Horizontal Shear Reinforcement:

-0.0594
Using BarØ= 16 mm
s2= -10.493 in ≈ -266.5222 mm
S2max= 157.48 in USED = 200 mm
ρmin= 0.0025 7.87 in
ρh = 0.00335 > ρmin=

Vertical Shear Reinforcement:

ρn= 0.0033287501

Using BarØ= 16 mm
s2= 7.927 in ≈ 201.3458 mm
S2max= 262.467 in USED = 200 mm

CHECK FOR FLEXUREAL REINFORCEMENT:


Mu= 21237.647 Kip-in

2.51753229

ρ= 0.00004
As= ρbd
As= 0.595 in2

Using BarØ= 16 mm
s= 64.715 in ≈ 1643.761 mm
USED = 200 mm
Distance of Flexural = 194.488 ≈ 4.94 m
2.5 m

CHECK FOR FLEXURAL ALONG WEAK SECTION:


Wt= 450.707 Kip-in
Mu= 12345.649 Kip-in

31.221

ρ= 0.00052
As= ρbd
As= 4992 in2

Using BarØ= 16 mm
s= 24.828171122 in ≈ 40.27682889 mm
USED = 150 mm

FINAL LAYOUT DRAWING:


Ø 16 mm @ Ø 16 mm @
150 mm spacing E.F. 200 mm spacing E.F.

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2.5 m 2.5 m

20 m

PLAN DETAILED
in
in
in
in
in
in
in
spacing E.F.