DESIGN OF PIER WALL
PARAMETERS:
f'c = 3000 psi = 20.73 Mpa Hw= 11 m 433.071
fy = 60000 psi = 414.7 Mpa h= 0.6 m 23.622
µ= 0.5 Lw= 20 m 787.402
ca= 0.32 Ht. of dam crest= 7 m 275.591
δconc.= 23.5 Kn/m3 Max. Elev. Of flood= 10 m 393.701
width of gate= 2.2 m 86.614
d= 16 m 629.921
Nu= 5 Kip
HORIZONTAL FORCES
CASE DL (kip) DL2(Kip) LL(Kip) TOTAL (Kip)
NORMAL CONDITION 32.393 118.776 151.169
MAX. FLOOD 66.109 242.4 25 333.509
CHECK FOR THICKNESS:
Vu= 333.509
Vn=
Vn= 6112.581 Kip > 333.509 (OK)
CHECK FOR SHEAR:
Vc=
Vc= 2689.536 Kip
Vc= Mu= 15865.76 Kip-f
Vc= 5016846.375 Kip
CHECK FOR SHEAR REINFORCEMENT:
1008.576 Kip > 333.509 Kn
Horizontal Shear Reinforcement:
-0.0594
Using BarØ= 16 mm
s2= -10.493 in ≈ -266.5222 mm
S2max= 157.48 in USED = 200 mm
ρmin= 0.0025 7.87 in
ρh = 0.00335 > ρmin=
Vertical Shear Reinforcement:
ρn= 0.0033287501
Using BarØ= 16 mm
s2= 7.927 in ≈ 201.3458 mm
S2max= 262.467 in USED = 200 mm
CHECK FOR FLEXUREAL REINFORCEMENT:
Mu= 21237.647 Kip-in
2.51753229
ρ= 0.00004
As= ρbd
As= 0.595 in2
Using BarØ= 16 mm
s= 64.715 in ≈ 1643.761 mm
USED = 200 mm
Distance of Flexural = 194.488 ≈ 4.94 m
2.5 m
CHECK FOR FLEXURAL ALONG WEAK SECTION:
Wt= 450.707 Kip-in
Mu= 12345.649 Kip-in
31.221
ρ= 0.00052
As= ρbd
As= 4992 in2
Using BarØ= 16 mm
s= 24.828171122 in ≈ 40.27682889 mm
USED = 150 mm
FINAL LAYOUT DRAWING:
Ø 16 mm @ Ø 16 mm @
150 mm spacing E.F. 200 mm spacing E.F.
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
2.5 m 2.5 m
20 m
PLAN DETAILED
in
in
in
in
in
in
in
spacing E.F.
0.6m