Design of Beam (Internal) at Midspan: Solution (Using NSCP 6th Edition)

- The beam is being designed for an internal moment of 196 kN-m and at the support for a moment of 56 kN-m. - For the internal design, the beam is compression controlled and requires compression reinforcement, so it will be designed as a doubly reinforced beam. - For the support design, the beam is tension controlled and does not require compression reinforcement, so it can be designed as a singly reinforced beam. - Reinforcement amounts and sizes are calculated based on the given dimensions, material properties, and design equations from the code.

Uploaded by

Nico Paulo Ruz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
204 views12 pages

Design of Beam (Internal) at Midspan: Solution (Using NSCP 6th Edition)

- The beam is being designed for an internal moment of 196 kN-m and at the support for a moment of 56 kN-m. - For the internal design, the beam is compression controlled and requires compression reinforcement, so it will be designed as a doubly reinforced beam. - For the support design, the beam is tension controlled and does not require compression reinforcement, so it can be designed as a singly reinforced beam. - Reinforcement amounts and sizes are calculated based on the given dimensions, material properties, and design equations from the code.

Uploaded by

Nico Paulo Ruz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 12

Design of Beam (internal) @ Midspan

Given: Overall depth = 350 mm


Designing Moment = 196.00 KN Depth (d) = 327 mm
Length = Breath (b) = 250 mm
fc' = 21 Bar diameters = 16 mm
fy = 420 Concrete cover = 15 mm
β1 = 0.85
Solution(Using NSCP 6th Edition):

ρmax = (3/7)((0.85fc'β1)/fy)
ρmax = 0.0154821

cmax = (3/7)d
cmax = 140.143 mm

amax = β1cmax
amax = 119.12 mm

51
Mnmax = /140β1fc'bd2(1-3/14β1)
Mnmax = 142.1652 KN.m

Reduction Factor (φ) = 0.65 + 0.25((800-fy)/(1000-fy))


Reduction Factor (φ) = 0.81379

Mucap = φMnMax
Mucap = 0.81379 x 142.165
Mucap = 115.693

Since Mucap = 115.69 KN.m < 196 KN.m


(To be designed as Doubly Reinforced Beam)
***Compression steel is needed
Design of Beam (internal) @ Midspan

Design for Singly Reinforced Beam (Using NSCP 2010 Edition)


Mu = 196.000 KN d = 327 mm
fc' = 21 MPa
fy = 420 MPa

Required As:
Reduction Factor (φ)
φMnT = (459/1600)(β1fc'bd2(1-3/16β1))
φMnT = 115.072

Since φMnT = 115.07 KN.m < 196.00 KN.m


The beam is Compression Controlled,φ = 0.65 + 0.25 ((fs - fy)/(1000-fy))

fs = 600(d-cmax)/cmax = 800
φ = 0.65 + 0.25 (fs-fy)/(1000-fy) = 0.81379
φ= 0.81379
To be safe:
Beam Capacity = 196 KN

Mu = φfc'ωbd^2(1-0.59ω)
196 x10 =
6
φfc'ωbd^2(1-0.59ω)
ω(1-0.59ω) 0.4290296
ω = Err:502

ρ = ω(fc'/fy)
ρ = Err:502

ρmin = 1.4/fy
ρmin = 0.0033333

Since ρmax Err:502 ρ Err:502 ρmin


0.01548 Err:502 0.00333

Adopt ρ = Err:502

As = ρbd
As = Err:502

No. of 16 mm bars = Err:502 pcs 6m length RSB


Design of Beam (internal) @ Midspan

Design for Doubly Reinforced Beam (Using NSCP 2010 Edition)


d = 327 mm
Mu = φMn ; φ = 0.81379 d' = 23 mm
Mn = Mn1 + Mn2 fc' = 21 MPa
Mu = φ( Mn1 + Mn2) fy = 420 MPa

Mucap = φMn1
115.69 = 0.81 x Mn1 Mn2 = Mu/φ - Mn1
Mn1 = 142.16521 Mn2 = 98.682249

Required Tensile Steel Reinforcement:


As = As1 + As2

T1 = C cmax = 140.143
As1fy = 0.85 fc' ab amax = 119.12

As1 x 420 = 0.85 x 21 x 119.12 x


As1 = 1265.6652 mm 2

Mn2 = T2(d-d')
Mn2 = As2fy(d-d')
98.68225x106 = As2 x 420 x( 327 - 23 )
As2 = 772.88729 mm 2

As = 1265.6652 + 772.887
As = 2038.5525 mm 2

Required compression reinforcement:


T2 = C'
As2fy = As'fy

Check if compression steel yields: fs' = 600(c-d')/c


fs' = 501.52905 Mpa

Since fs' = 501.52905 > fy


***Compression steel yields (fs'=fy)

As'fy = As2fy
As' = 772.88729 mm2 No. of 16 mm bars = 4 pcs 6m length RSB
As = 2038.5525 mm2 No. of 16 mm bars = 10 pcs 6m length RSB
250
Design of Beam (internal) @ Support

Given: Overall depth = 400 mm


Designing Moment = 55.79 KN Depth (d) = 352 mm
Length = Breath (b) = 200 mm
fc' = 21 Bar diameters = 16 mm
fy = 345 Concrete cover = 40 mm
β1 = 0.85
Solution(Using NSCP 6th Edition):

ρmax = (3/7)((0.85fc'β1)/fy)
ρmax = 0.01885

cmax = (3/7)d
cmax = 150.857 mm

amax = β1cmax
amax = 128.23 mm

51
Mnmax = /140β1fc'bd2(1-3/14β1)
Mnmax = 131.7872 KN.m

Reduction Factor (φ) = 0.65 + 0.25((800-fy)/(1000-fy))


Reduction Factor (φ) = 0.82366

Mucap = φMnMax
Mucap = 0.82366 x 131.787
Mucap = 108.548

Since Mucap = 108.55 KN.m > 56 KN.m


(To be designed as Singly Reinforced Beam)
***Compression steel is not needed
Design of Beam (internal) @ Support

Design for Singly Reinforced Beam (Using NSCP 2010 Edition)


Mu = 55.79 KN d = 352 mm
fc' = 21 MPa
fy = 345 MPa

Required As:
Reduction Factor (φ)
φMnT = (459/1600)(β1fc'bd2(1-3/16β1))
φMnT = 106.672

Since φMnT = 106.67 KN.m > 55.79 KN.m


The beam is Tension Controlled,φ = 0.90

φ 0.90

To be safe:
Beam Capacity = 55.79 KN

Mu = φfc'ωbd^2(1-0.59ω)
55.79 x10 =
6
φfc'ωbd^2(1-0.59ω)
ω(1-0.59ω) 0.1191185
ω = 0.1289253

ρ = ω(fc'/fy)
ρ = 0.0078476

ρmin = 1.4/fy
ρmin = 0.004058

Since ρmax > ρ > ρmin


0.01885 0.0078 0.00406

Adopt ρ = 0.00785

As = ρbd
As = 552.47308

No. of 16 mm bars = 3 pcs 6m length RSB


Design of Beam (internal) @ Support

Design for Doubly Reinforced Beam (Using NSCP 2010 Edition)


d = 352 mm
Mu = φMn ; φ = 0.82366 d' = 48 mm
Mn = Mn1 + Mn2 fc' = 21 MPa
Mu = φ( Mn1 + Mn2) fy = 276 MPa

Mucap = φMn1
108.55 = 0.82 x Mn1 Mn2 = Mu/φ - Mn1
Mn1 = 131.78717 Mn2 = -64.05325

Required Tensile Steel Reinforcement:


As = As1 + As2

T1 = C cmax = 150.857
As1fy = 0.85 fc' ab amax = 128.23

As1 x 345 = 0.85 x 21 x 128.23 x


As1 = 1326.887 mm 2

Mn2 = T2(d-d')
Mn2 = As2fy(d-d')
-64.0533x106 = As2 x 276 x( 352 - 48 )
As2 = -763.4112 mm 2

As = 1326.887 + -763.41
As = 563.47579 mm 2

Required compression reinforcement:


T2 = C'
As2fy = As'fy

Check if compression steel yields: fs' = 600(d'-c)/c


fs' = 409.09091 Mpa

Since fs' = 409.09091 > fy


***Compression steel yields (fs'=fy)

As'fy = As2fy
As' = -763.4112 mm2 No. of 16 mm bars = -4 pcs 6m length RSB
As = 563.47579 mm2 No. of 16 mm bars = 3 pcs 6m length RSB
ort

200
Stirrup Design of Beam

Distance from the support = 0 mm


Designing Shear = 39.14 KN
Wu = 7.43 KN/m
Given:

bw = 200 mm Stirrup diameter = 10 mm


d = 352 mm λ = 1
fc = 21 Stirrup crossing the crack = 2
fyt = 345

Shear strength provided by the concrete:

Vc = 0.17λ(√fc')bw d φVc = 41.133199 KN


Vc = 54.8443 KN ⅟2φVc = 20.5666 KN

0.66√fc'bwd = 212.9248
0.33√fc'bwd = 106.4624
Av = 2x 78.5398163
Av = 157.08

*A mimimum area of shear reinforcement is required

s max1 = d/2
s max1 = 176

Avmin = 0.062√fc'(bws/fyt) >= (0.35bws/fyt)


s max2 = Avfyt/(0.062√fc' bw)
s max2 = 953.691
s max3 = Avfyt/0.35bw
s max3 = 774.178

Use 10 mm vertical U stirrup at 176 on centers


Stirrup Design of Beam

Distance from the support = 352 mm


Designing Shear = 36.52464 KN

*A mimimum area of shear reinforcement is required

s max1 = d/2
s max1 = 176

Avmin = 0.062√fc'(bws/fyt) >= (0.35bws/fyt)


s max2 = Avfyt/(0.062√fc' bw)
s max2 = 953.691
s max3 = Avfyt/0.35bw
s max3 = 774.178

Use 10 mm vertical U stirrup at 176 on centers

Distance from the support = 478 mm


Designing Shear = 35.58846 KN

*A mimimum area of shear reinforcement is required

s max1 = d/2
s max1 = 176

Avmin = 0.062√fc'(bws/fyt) >= (0.35bws/fyt)


s max2 = Avfyt/(0.062√fc' bw)
s max2 = 953.691
s max3 = Avfyt/0.35bw
s max3 = 774.178

Use 10 mm vertical U stirrup at 176 on centers

Therefore:
Stirrup spacing:
Use 2 stirrups at 176 mm spacing
Use 3 stirrups at 176 mm spacing
Rest at 176 mm spacing