CTR 8500-8300 3.6.0 Backup Power CLI Commands - July2018
CTR 8500-8300 3.6.0 Backup Power CLI Commands - July2018
Backup Power
CLI Commands
Version 3.6.0
260-668501-001
Build 41.5505
BACKUP POWER
Warranty
Aviat Networks makes no representation or warranties with respect to the contents hereof
and specifically disclaims any implied warranties or merchantability or fitness for any
particular purpose.
Further, Aviat Networks reserves the right to revise this publication and to make changes
from time to time in the content hereof without obligation of Aviat Networks to notify any
person of such revision or changes.
Safety Recommendations
The following safety recommendations must be considered to avoid injuries to persons
and/or damage to the equipment:
1. Installation and Service Personnel: Installation and service must be carried out by
authorized personnel who have the technical training and experience necessary to be
aware of any hazardous operations during installation and service, and of measures to
avoid any danger to themselves, to any other personnel, and to the equipment.
2. Access to the Equipment: Access to the equipment in use must be restricted to service
personnel only.
3. Safety Norms: Recommended safety norms are detailed in the Health and Safety
sections of the Eclipse User Manual.
4. Service Personnel Skill: Service personnel must have received adequate technical
training on telecommunications and in particular on the equipment and capabilities this
addendum refers to.
Trademarks
All trademarks are the property of their respective owners.
IV AVIAT NETWORKS
BACKUP POWER
Americas Technical Help Desk EMEA Technical Help Desk Asia Pacific Technical Help Desk
Aviat Networks, Inc. Aviat Networks Aviat Networks
San Antonio, TX Blantyre, Glasgow, Scotland Clark Freeport Zone
U.S.A. G72 0FB Philippines 2023
United Kingdom
Phone:+1 210 526 6345 Phone: +1 210 526 6345 Phone: +1 210 526 6345
Toll Free (USA): Fax: Fax: +63 45 599 5196
+1 800 227 8332 +44 16 9871 7204 (English)
Fax:+1 210 526 6315 +33 1 5552 8012 (French)
Email: [email protected] Email: [email protected] Email: [email protected]
Or you can contact your local Aviat Networks office. Contact information is available on our
website at: http://www.aviatnetworks.com/services/customer-support/technical-
assistance/
VI AVIAT NETWORKS
BACKUP POWER CHAPTER 2
Backup Power
These commands allow the user to configure parameters for the power plugin.
l backup-power - Configure a slot to expect backup power to be present.
l no backup-power - Configure a slot to not expect backup power to be present.
l show backup-power -Shows information about a power plugin card.
Prerequisite
To enable backup power, you must configure slot 1 as pwr, using the following commands:
aos(config)# slot 1 pwr
aos(config)#
slot [<chassis>/]<slot> <module>
aos(config)# slot 1
backup-power
Configures a slot to expect backup power to be present.
Syntax
backup-power slot [<chassis>/]<slot>
Parameters
chassis
The chassis where the power card is.
slot
The slot number where the power card is.
Command Mode
Global Configuration
Example
aos# configure terminal
aos(config)# backup-power slot 1
no backup-power
Configures a slot to not expect backup power to be present.
Syntax
no backup-power slot [<chassis>/]<slot>
Parameters
chassis
The chassis where the power card is
slot
The slot number where the power card is
Command Mode
Global Configuration
Example
aos# configure terminal
aos(config)# no backup-power slot 1
show backup-power
Shows information about a power plugin card. If the chassis and slot is not given this
command will show information about all power plug-in cards.
Syntax
show backup-power [slot [<chassis>/]<slot>]
Parameters
chassis
The chassis where the power card is
slot
The slot number where the power card is
Command Mode
User EXEC / Privileged EXEC
Examples
aos> show backup-power slot 1/1
1/1 - Backup Power: expected Voltage: 45.853 V Temperature: 27.5
C
aos> show backup-power
1/1 - Backup Power: Compatible module not detected