Using The 8T-2700 Blowby/Air Flow Indicator (0774, 0781, 0785)
Using The 8T-2700 Blowby/Air Flow Indicator (0774, 0781, 0785)
Página 1 de 34
Cerrar SIS
Pantalla anterior
Instrucción Especial
Using the 8T-2700 Blowby/Air Flow Indicator {0774, 0781,
0785}
Número de medio -SEHS8712-03Fecha de publicación -01/01/2005Fecha d
i02104788
Introduction
The 8T-2700 Blowby/Air Flow Indicator has a digital readout that is capable
of displaying either volume or air flow. The blowby/air flow indicator
displays Metric units. The blowby/airflow indicator also displays US
Customary units.
The blowby/air flow indicator can measure the exhaust gas that escapes from
the crankcase. The gas that escapes is commonly known as blowby.
Measuring the blowby helps the technician assess the condition of the
cylinder, which can be very helpful in determining when engine repair is
needed. The amount of blowby can be displayed in liters per minute or in
cubic feet per hour.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {07... Página 2 de 34
The blowby/air flow indicator can measure the airflow that passes through the
radiator core. Measuring the airflow helps the technician locate areas in the
radiator core that have become restricted. The rate of airflow can be displayed
in meters per minute or in feet per minute.
Adaptability
Illustration 1 g00815969
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {07... Página 3 de 34
Illustration 2 g00817505
(2) The vinyl hose has an ID of 19.05 mm (0.75 inch). The wall thickness of
the vinyl hose is 3 mm (0.125 inch). The length of the vinyl hose is 1524 mm
(5 ft). The nipple is 12.7 mm (0.50 inch) male pipe by 19.05 mm (0.75 inch)
with a 12.7 mm (0.5000 inch) hose clamp.
(4) The hose clamps have an operating range of 19.05 mm (0.75 inch) to 50.8
mm (2.00 inch). Two hose clamps are included.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {07... Página 4 de 34
(11) The 8T-2701 Blowby Indicator As comes with the following 4 Vinyl
hoses.
z The first vinyl hose has an ID of 22 mm (0.875 inch). The wall thickness
is 3 mm (0.125 inch). The length of the hose is 102 mm (4 inch).
z The second hose has an ID of 6.35 mm (0.25 inch). The wall thickness is
5 mm (0.185 inch). The length of the hose is 102 mm (4 inch).
z The third hose has an ID of 38.1 mm (1.50 inch). The wall thickness is 5
mm (0.185 inch). The length of the hose is 102 mm (4 inch) long.
z The fourth hose has an ID of 50.8 mm (2.00 inch). The wall thickness is 5
mm (0.185 inch). The length of the hose is 102 mm (4 inch).
(12) The length of the PVC pipe is 305 mm (12 inch). The diameter of the
PVC pipe is 12.7 mm (0.5 inch). There is also a PVC Schedule 40 Bushing.
Storage Memory - Three separate storage memories record the minimum, the
maximum, and the different values of the measurements that are being taken.
These values may be displayed at any time.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {07... Página 5 de 34
Hold Function - The display may be held constant for any length of time.
A power saving feature turns the display off if the probe is not used for 15
minutes. This auto turn-off feature may be disabled.
Low Battery Voltage Indicator - When the internal battery or external power
is less than 6 volts, "LO BAT" will appear on the display. The blowby/airflow
indicator will remain accurate until the voltage drops to 5.5 volts.
Once "LO BAT" appears on the display, two hours of continuous operation
will remain or five hours of intermittent operation will remain.
Specifications
Power
Measuring Range
Accuracy
Resolution
Blowby ... one liter per minute (one cubic foot per minute)
Air flow ... one meter per minute (one foot per minute)
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {07... Página 6 de 34
Normal Rate - Data measured 2 1/2 times per second. The LCD is updated at
one second intervals.
Medium Rate - Data measured 2 1/2 times per second. The LCD is updated
at five second intervals.
Slow Rate - Data measured 2 1/2 times per second. The LCD is updated at 10
second intervals.
Operating Temperature
Storage Temperature
Size
Weight
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {07... Página 7 de 34
Indicator
Illustration 3 g00816576
Connector for the External Power Source - The connection for the external
power source is 11 to 40 VDC. This connection is not required if a good 9 volt
battery is installed in the indicator.
Use the optional 5P-7366 Power Cable to connect to the machine battery.
The optional 8T-5268 Converter connects at location (1) for 110/230 VAC.
Connector for Blowby Pickup - Install 8T-2685 Blowby Pickup or the 1U-
8860 Blowby Pickup at location (2). Use the 8T-5297 Cable As . The 6V-
2198 Cable may be used if a longer cable is required.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {07... Página 8 de 34
Illustration 4 g00816591
(1) "HOLD" - The value on the display is being held and the value will not
change even if the values change.
Note: An arrow will appear on the display next to the label to indicate the
following functions.
(3) "UNDER" - The flow rate is under the range of the indicator. The display
will be blank.
(5) "NORM" - The display is being updated at the normal rate of one second
intervals.
(7) "MED" - The display is being updated at the medium rate of five second
intervals.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {07... Página 9 de 34
(9) "SLOW" - The display is being updated at the rate of 10 second intervals.
(11) "MIN" - The minimum value that is recorded during the test
(13) "MAX" - The maximum value that is recorded during the test
(14) "DIFF INDICATOR" - The difference in the values that are recorded
for minimum and maximum
Illustration 5 g00816655
(1) "L/MIN" - After pressing, the display will indicate the amount of blowby
in liters per minute. An arrow will appear on display next to "L/MIN".
(2) "FT3/HR". - After pressing, the display will indicate the amount of
blowby in cubic feet per hour. An arrow will appear on display next
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 10 de 34
to"FT3/HR".
(3) "M/MIN" - After pressing, the display will indicate the amount of air
flow in meters per minute. An arrow will appear on display next to "M/MIN".
(4) "FT/MIN" - After pressing, display will indicate the amount of air flow in
feet per minute. An arrow will appear on display next to "FT/MIN".
(5) "MIN" - This button displays the minimum value that is recorded during
the test once the "CLEAR" button is initially pressed. An arrow will appear on
display above "MIN".
(6) "MAX" - This button displays the maximum value that is recorded during
the test once the "CLEAR" button is initially pressed. An arrow will appear on
display above "MAX".
(7) "DIFF" - After pressing, the display will indicate the difference between
the minimum value and the maximum value, once the "CLEAR" button is
initially pressed. An arrow will appear on display above "DIFF". This
function is only for blowby .
(8) "ACTUAL" - After pressing, this will display the current actual value. An
arrow will appear on display above "ACTUAL".
(9) "CLEAR" - After pressing, the memories will be cleared for the "MIN"
value, the "MAX" value, and the "DIFF" value. The value that is currently
displayed will be entered into the memory for the "MIN" and the "MAX"
when the "CLEAR" button is pressed.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 11 de 34
(13) "HOLD" - When you press this button, the "MIN", "MAX", "DIFF", or
"ACTUAL"readings will not change until the "HOLD" and "CLEAR" buttons
are pressed or until the indicator is turned off.
(14) "HOLD CLEAR" - If the reading on the display is being held, this
button will allow the reading to be updated to the current value. The arrow
next to "HOLD" will disappear when the "HOLD" button is pressed.
(16) "OFF" - This button turns the indicator off. No memories are retained.
Note: The battery must be changed within two hours after "LO BAT" appears
on the display, or inaccurate results will be obtained.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 12 de 34
Illustration 6 g00816769
1. Remove six screws (1) from the rear cover. Remove cover (2) .
Illustration 7 g00816773
2. To remove battery (3), pull upward on the battery and remove the battery
from the holder.
Note: Be sure that the positive (+) terminal on the battery is on the
positive (+) terminal in the holder.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 13 de 34
Illustration 8 g00816858
Note: Always connect one of the clips to the frame of the machine.
Connect the other clip to the positive (+) terminal on the battery. The
connector is not polarized. Either clip may be connected to the positive
(+) terminal on the battery or to the machine frame.
Fuse Replacement
Use the following procedure to check and replace these fuses if the indicator
fails to operate.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 14 de 34
Illustration 9 g00816769
1. Remove six screws (1) from the rear cover, and remove cover (2) from
the indicator.
Illustration 10 g01090583
2. Locate two fuses (3) on the printed circuit board. The fuses are located
directly behind the connector for the external power source. You do not
need to remove the fuses from the holders for the check.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 15 de 34
Note: A good fuse will measure less than 1 ohm resistance. A damaged fuse
will measure infinite ohm "OL" on the multimeter display. Replace the
damaged fuse with a 8K-4644 Fuse .
2. Plug the connector on the 8T-5268 Converter into the connector for the
external power source on the blowby/airflow indicator. Plug the converter
into an AC outlet. For operation outside the USA, an AC adapter may be
required.
3. Once the power has been supplied, the blowby/airflow indicator will
operate whenever the "ON" button is pressed.
Operating Instructions
Checking the Operation of the Blowby/Air Flow Indicator
The following procedure may be used to check the operation of the 8T-2701
Blowby Indicator As , the 8T-2685 Blowby Pickup , or the 1U-8860 Blowby
Pickup . This procedure is designed to test the operation of the systems only.
This test is not intended to check for accuracy.
The components for this test are the blowby/airflow indicator, the 8T-5297
Cable , and the blowby pickup. Perform the following steps.
2. When you press the "ON" button, the letters "OF" should flash on the
display. This display indicates that a pickup has not been installed or that
the cable is broken.
3. Use the 8T-5297 Cable to connect the 8T-2685 Blowby Pickup to the
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 16 de 34
blowby/airflow indicator. The flashing should stop and the display should
read "0".
6. Blow air into the pickup in the direction of the arrow on the pickup.
Observe the reading on the display. The display should show
approximately 300 to 900 "FT/MIN".
7. Press the "M/MIN" button. the arrow should point to "M/MIN". Blow air
into the pickup. The display should show approximately 100 to 400
"M/MIN".
8. Press the "FT3/HR" button. The arrow should point to "FT3/HR". Blow
air into the pickup. The display should show approximately 100 to 400
"FT3/HR".
9. Press the "L/MIN" button. The arrow should point to "L/MIN". Blow air
into the pickup again. The display should show approximately 10 to 80
"L/MIN".
10. Press the "MAX" button. The arrow should point to "MAX". A number
should be on the display. The maximum value should be 900 during the
last four tests. Remember this number for the next test.
11. Press the "MIN" button. The arrow should point to "MIN". The display
should read "0".
12. Press the "DIFF" button. The arrow should point to "DIFF". The display
should read the difference between "MIN" and "MAX". The value for the
"DIFF" should equal the value for the "MAX".
13. Press the "CLEAR" button and look at the values in "MIN", "MAX" and
"DIFF". The values should be "0".
14. Blow air into the pickup continuously after you press the "MIN" button in
order to check the "MIN" function. The display will read "0". While you
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 17 de 34
are still blowing air, press the "CLEAR" button. A value will appear on
the display. This value is the minimum value that appeared. When you
stop blowing air into the pickup, the display will go to "0". This value is
the new minimum value.
15. In order to check the "HOLD" function, repeat Step 14. While you blow
air into the pickup, press the "HOLD" button after you press the
"CLEAR" button. The minimum value should stay on the display and an
arrow should appear next to "HOLD". Press the "HOLD" button and the
"CLEAR" button. The number on the display should go to "0". The arrow
next to "HOLD" should disappear.
16. In order to check the "RATE" buttons, press the "FT/MIN" button and the
"ACTUAL" button. The arrow for the "NORM RATE" button should
indicate that the "NORM RATE" button has been depressed. You should
vary the force of the air into the pickup. The reading on the display
should change accordingly. The reading should change every second.
Press the "MED RATE" button. The reading should change in five
second intervals. Press the "SLOW RATE" button. The reading should
change in 10 second intervals.
17. Press the "OFF" button. The display should be blank. This completes the
test of the blowby/Air Flow Indicator.
Test Procedure
Hookup for Checking Blowby
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 18 de 34
Illustration 11 g00816870
1. Attach the 1.5 m (5 ft) hose (4) to the most convenient location on the
crankcase breather output tube or the breather hose. Connect appropriate
sized bushing (3) and hose (2) to the crankcase breather. Secure hose
with clamps (1) .
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 19 de 34
Illustration 12 g00816873
2. Attach 8T-2685 Blowby Pickup (5) to the hose by sliding the pickup into
hose (4).
Note: Install pickup (5) with arrow (6) in the direction of the air flow.
Measuring Blowby
Note: The 8T-2685 Blowby Pickup is sensitive to noise or movement of air.
In order to prevent inaccurate readings, keep the pickup away from the engine
fan and any movement of air past the end of the pickup.
1. Start and run the engine until normal operating temperature is reached.
c. Press the "NORM RATE" button. An arrow must appear next to the
selection.
3. Run the engine at high idle. The value of the blowby will be displayed.
The display will change whenever the amount of blowby changes.
a. After you test the minimum blowby, test the maximum blowby and
record the difference between the two. Press the buttons in order to
recall the "MIN", the "MAX", or the "DIFF" between the two
readings.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 20 de 34
b. Press the "CLEAR" button in order to retest the "MIN" and "MAX".
Note: Do not press the "HOLD" button until the check has been completed.
The readings will not change after the "HOLD" button is pressed. The
memory will retain the values until the "HOLD CLEAR" button is pressed or
until the blowby/airflow indicator is turned off.
Analyzing Results
Note: Do not use the data alone to determine if the engine should be
overhauled. The obtained data from the blowby/air flow indicator should only
be used for additional information. Other indicators such as high oil
consumption, low power, hard starting, and excessive fuel consumption must
be considered.
The data from the blowby/air flow indicator should be used in order to
establish a trend for the engine. You should not make a decision in order to
repair an engine on the results of a single blowby test.
After a new engine is used for a short time, the blowby can decrease as the
rings are seated. New engines should be checked for blowby during all
maintenance checks. As the piston rings and cylinder walls wear, the blowby
will gradually increase. Other sources of blowby can be worn valve guides or
leaking turbocharger seals.
The blowby on a worn engine may be two times or more than the blowby of a
new engine and may indicate the need for an overhaul.
An engine that has been overhauled can have a high rate of blowby due to
several factors: improperly seated rings, worn parts which were not changed
and worn valve guides.
Always check the blowby by the same method for better comparison of future
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 21 de 34
tests. Read the rate of blowby at full engine RPM, either at no load or at full
load. The blowby could vary as much as 100 percent under a no load
condition to a full load condition. Use the highest reading for the actual
blowby value.
The blowby meter is sensitive to engine noise at high frequencies. When you
are making blowby measurements, keep the blowby pickup as far away from
the engine as possible. Do NOT put the pickup near the turbocharger or fan
blades, as this can cause a reading error.
The rates of blowby for new Caterpillar engines without ACERT technology
are shown in the chart below. The rates of blowby are typical. The readings
are not the absolute rates of blowby. Do not base your decision for repairs on
only the readings.
Table 1
Typical Blowby Rates for New (Low Hour) Caterpillar Engines without
ACERT technology
Ring Blowby Blowby High Idle No Load
Engine Package Range Ft Range Blowby/HP Ratio
3 L/Min 3 L/Min
/Hour Ft /Hour
3204 NA
2 ring 90-100 42-47 1.0 0.5
3204 DIT
2 ring 110-240 52-110 2.0 1.0
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 22 de 34
Plugging of the radiator core is the most common cause of poor air flow. The
blowby/airflow indicator measures the air flow through the radiator core. The
blowby/airflow indicator also helps pinpoint the exact location of a restriction
in the radiator core.
The blowby/airflow indicator is most effective with blower fans. Suction fans
tend to average the air flow across the core. A radiator core that has plugged
areas will have a reduction of air flow.
The air that flows across the radiator core may not be consistent. The items
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 23 de 34
that follow affect the air that flows across the radiator core:
z Air swirl
z Guards
z Braces
z Position of engine mounted components
Illustration 13 g00817521
The air flow rises sharply at the inner tip (2) of the fan blade. The air flow
gradually increases to a maximum at the outer tip (1).
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 24 de 34
Illustration 14 g00817541
The flow of air is lowest at the center of the fan hub (5). Maximum air flow is
found in the area of the fan blades (4).
The flow of the air in the corners of radiator core (3) are generally less than
flow of the air in area (4). However, the flow of the air in the corners of
radiator core (3) are higher than the flow of air in area (5) .
Turn off the engine and place a light behind the radiator core. Inspect the
radiator core for plugged areas. The fan guards may limit the visibility of the
inspection.
If area (4) of the radiator core is plugged, the rest of the radiator core could be
plugged. The light may show through area (4) and the radiator core can still be
plugged in area (3). This is due to air velocity that has not been high enough
to blow material through the core.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 25 de 34
Illustration 15 g00826690
Note: Ensure that the air flow is in the direction of arrow (8). The end of
pipe (6) should be against the radiator core during the test.
Illustration 16 g00826739
3. Press the "ON" button. Select the following functions with the buttons on
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 26 de 34
4. Start the engine and run the engine at high idle. Check the air flow by
placing the PVC pipe against the radiator core.
Note: Air flow below 43 "M/MIN" (141 "FT/MIN") will read "0" on the
blowby/airflow indicator .
5. Check the air flow by using circular patterns at an equal distance from the
fan hub. The air flow can be decreased at some point in any circular
pattern.
A blocked radiator core or a restricted radiator core will cause a decrease in
the air flow.
1. Remove the internal battery. Follow Step 1 and Step 2 in ""Replacing the
Internal Battery" ".
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 27 de 34
Illustration 17 g00817708
2. Remove four screws (1) that are located on the corners of the small
printed circuit board (2) .
Note: Care must be taken when you remove the small circuit board (2) in
order to prevent damage to the conductors.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 28 de 34
Illustration 18 g00815991
4. Locate the connector for the auto turn-off feature on the large circuit
board. The connector is located between the battery and the integrated
circuit (40 pin).
5. Lift the connector and move the connector to the next set of pins that are
closest to the battery. This will disable the auto turn-off feature. The
Illustration18 shows the proper location of the connector for each mode
of operation.
6. Carefully place the small circuit board (2) on top of the large printed
circuit board. Ensure that the connector for the two circuit boards is
properly aligned before you press the two circuit boards together.
7. Install four screws (1) in the corners of small board (2). Replace the
battery and install the rear cover.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 29 de 34
2. Remove the small printed circuit board. Follow Step 3 and Step 4 in
""Disabling the Auto Turn-off Feature (If Equipped)" ".
Illustration 19 g01090586
3. Remove six screws (3). Lift up the printed circuit board (4) from the front
cover. Be sure to lift the printed circuit board from the LCD end.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 30 de 34
Illustration 20 g00826754
4. Carefully remove the 8T-0999 Membrane Switch connector (5) from the
connector pins (6) .
Replacement Procedure for the 8T-0844 Front Cover and the 8T-
0999 Membrane Switch
Note: Always replace both the front cover and the membrane switch even if
only one is damaged.
2. Start at the window end of the membrane switch. Carefully peel the
backing from the 8T-0999 Membrane Switch while you align the
membrane switch with the 8T-0844 Front Cover .
Note: Before you glue the switch in place, make sure that the switch
connector is properly installed through the slot in the front cover.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 31 de 34
Illustration 21 g00826872
Illustration 22 g00826873
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 32 de 34
Illustration 23 g00826864
3. Remove 8T-0887 Connector As (8) and 8T-1005 LCD display (12) from
the circuit board.
Note: Do not touch strips (14) with bare hands. If the strips need to be
placed into the slots in frame (13), use a tweezers.
Illustration 24 g00826875
The pins on the bottom of the frame of the connector must fit into holes
(15) .
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 33 de 34
Illustration 25 g00826876
5. Place the assembled frame (13) and strips (14) on the large circuit board.
6. Hold the digital LCD display (12) in front of a light in order to determine
which end the "LO BAT" display is on. Do not lose this orientation.
7. Place theLCD display on top of the strips with the "LO BAT" on the left.
8. Place shield (11) on top of the LCD display. Put cover (10) over the
shield and install four screws (7) in the large circuit board.
9. Make sure that the connector for the membrane switch (5) is properly
aligned with the pins (6) on the large circuit board. Press the components
together.
10. Install six screws (3). Carefully place the small circuit board on top of the
large circuit board.
11. Align the connector for the circuit boards before you press the two boards
together.
12. Install four screws (1) in the corners of small circuit board (2). Replace
the battery and the rear cover.
Repair Information
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 21/08/2008
Búsqueda del medio - SEHS8712 - Using the 8T-2700 Blowby/Air Flow Indicator {... Página 34 de 34
Units that are less than one year old will be repaired under the warranty. The
cost of repairs that are out of warranty will be charged to the owner.