Diffraction by A Plane Grating: Objective

This document describes an experiment to study diffraction using a plane grating and measure the wavelength of spectral lines from a mercury lamp. [1] The grating produces a diffraction pattern according to an equation relating intensity to wavelength and grating parameters. [2] Maxima occur when the path difference between rays is an integer multiple of the wavelength, relating diffraction angle to wavelength. [3] The procedure outlines initial alignment of the optical components and measurement of diffraction angles to determine wavelengths of mercury lines and the grating's resolving power using sodium D lines.

Uploaded by

s musarrat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views

Diffraction by A Plane Grating: Objective

This document describes an experiment to study diffraction using a plane grating and measure the wavelength of spectral lines from a mercury lamp. [1] The grating produces a diffraction pattern according to an equation relating intensity to wavelength and grating parameters. [2] Maxima occur when the path difference between rays is an integer multiple of the wavelength, relating diffraction angle to wavelength. [3] The procedure outlines initial alignment of the optical components and measurement of diffraction angles to determine wavelengths of mercury lines and the grating's resolving power using sodium D lines.

Uploaded by

s musarrat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 3

5.

Diffraction by a Plane Grating

Objective
To study the diffraction of light with a plane grating and to measure the wave length of
various spectral lines in Hg lamp and the resolving power of the grating.

Theory
A diffraction grating consists of large number of slits each of width b which are separated
by distance d called the spatial period. A plane wave incident normally on a grating
produces a diffraction pattern, the intensity variation I of which is given by

sin 2 b sin 2 N g
I = Io (1)
b 2 sin 2 g

Where 2b=kbsind is the phase difference between the Huygens secondary waves coming
from extreme edges of a slit, 2 g=kdsind is the phase difference between the Huygens
secondary waves from corresponding points in any two adjacent slits, Io is the intensity
of the incident light, d is the diffraction angle, N is the no. of slits and k =2/ is the
magnitude of the wave vector ( being the wavelength of light). Since the width of each
slit in the grating is small, the effect of b can be neglected and the intensity variation can
be written approximately as
sin 2 N g
I = Io (2)
sin 2 g
From equation 2 it can be seen that maxima will occur whenever g=m where m is the
diffraction order. This thus corresponds to

dsind =m m=0, 1, 2 --- (3)

Equation 3 shows that light of different wavelengths get diffracted at different angle from
the central maxima. It is this property of the grating that makes it an useful dispersion
element in optics.

Procedure

Measurement of various spectral lines in a mercury lamp.

Set the telescope for viewing the object at infinity and the collimator for the parallel
beam of light as described in the lecture 2 of this module. Use the mercury lamp for this
experiment.When all these initial adjustments are over, the grating may be mounted for
normal incidence. To do this following steps are to be followed.
1. Align the collimator and the telescope in a straight line. Locate the image of the slit
at the crosswire. Note down the angular readings. Lock the prism table.
2. Rotate the telescope by 90and lock it, Fig 1.

3. Mount the grating on the grating table as shown in fig 2.

Fig 2 mounting of grating (this may be replaced by better photograph)

and rotate the table without changing the angle between the telescope and collimator till
you see a reflected image of the slit at the telescope Fig 3. Note down the angular
reading. This will make the angle of incidence on to the grating at 45.

Fig 3. Grating mounted at 45 . C: Collimator, G: Grating, T: Telescope.


4. Now rotate the grating table by 45, the sense of rotation should be in such a direction
that the angle of incidence becomes zero. This will set the grating for normal incidence.
Rotate the telescope till the new reading differs from the reading taken in step 3 by 45 to
make it collinear with the collimator as shown in Fig 4. Lock the table again and note
down this reading. This will be the initial direct reading.

Fig 4. Grating Aligned for normal incidence


Did you understand the reason for the above steps? As the condition of maxima
given in eq 3, is valid for the normal incidence and hence the grating is required to
be set for normal incidence.

5. With the slit width narrowed down sufficiently, find the angular locations of the
telescope for different diffracted coloured images of the slit with respect to the direct
reading. The differences between the angular readings for different colours and the direct
reading give the angles of diffraction for various wavelengths. The grating period of d is
given by the manufacturer usually in terms of number of lines per cm.

Analyses
1. Determine the emission wavelengths in the spectrum of the given line source, using
Eq. (3).
2. Estimate the errors in the measurement of .

Measurement of resolving power of a grating


The resolving power of grating is given by . Where  is the wave length of a
D
particular line and is the separation between the closet line which can be resolved by the
given grating. From eq 3


= tan  d D d , (4)
D

where d is the diffraction angle in the given order and Dd is the corresponding angular
separation of the nearest line. Equation 4 can be used to measure the resolving power of a
grating experimentally.

Procedure:

1. In the above experiment replace the mercury lamp with the sodium lamp
and do the alignment fro the grating as described above.
2. Set the grating for first order for the sodium D lines. Measure the angular
position for both the lines. The wave lengths for sodium d lines are 5890 nm
and 5896nm.
3. measure the angulr positions in second order also.
Analyses

Calculate the angular separation Dd for both the orders and estimate from eq 4.