BUILDING MEP SYSTEM
MEP SERVICES
• MEP or Mechanical, Electrical, and Plumbing
is an important part of building project
required for creating a safe and comfortable
environment inside the building.
• In simple terms, it is the prerequisite to begin
on a construction project and MEP
(Mechanical, Electrical, Plumbing)
coordination is one of the most challenging
tasks faced by the engineers and professionals
as they can account for up to 40 to 60% of the
project
INTRODUCTION TO MEP
ELECTRICAL SYSTEM
MECHANICAL SYSTEM MEP PLUMBING SYSTEM
CIVIL CO-ORDINATION
MECHNICAL SYSTEM
• HVAC SYSTEM
Air Conditioning
Ventilation, Exhaust ,Pressurization & smoke extraction
• FIRE FIGHTING SYSTEM
REFERENCE STANDARD OF HVAC
• National Building Code of India (NBC) 2005 / NBC 2015
• Energy Conservation Building Code (2009)
• ASHRAE Hand Books.
• Refrigeration 2014
• Fundamentals 2013
• HVAC Systems and Equipment 2012
• HVAC Applications 2011
• Air filters as per ASHRAE 52.1-1992 and 52.2-2010
• Duct construction standards as per relevant BIS Codes &
DW-144, SMACNA standards
• Indoor Air Quality as per ASHRAE 62.1-2010
• Motors, cabling, wiring and accessories as per BIS Codes
• ASHRAE Standard 90.1 2010
AIR CONDITIONING
TYPES OF AIR CONDITIONING
AIR CONDITONING
NON DUCTED PRODUCTS DUCTABLE SYSTEMS
SPLIT AIR CONDITIONING WINDOW AIR CONDITIONING PACKAGED AIR CONDITIONING CENTRAL PLANT
AIR COOLED CHILLED WATER
FLOOR STANDING PACKAGED AC DX SYSTEM
DUCTABLE SPLITS SYSTEM
WATER
FLOOR CEILING WALL AIR COOLED COOLED VAPOUR VAPOUR
MOUNTED MOUNTED MOUNTED
COMPRESSION UNIT ABSORPTION UNIT
RECIPROCATING SCREW TYPE RECIPROCATIN CENTRIFUGAL SCREW TYPE
EXPOSED CASSETTE UNITS AIR &
CENTRIFUGAL
UNITS WATER UNITS AIR & G UNITS AIR & UNITS WATER UNITS AIR &
TYPE TYPE WATER WATER COOLED WATER COOLED
COOLED COOLED WATER COOLED
COOLED
HIDE AWAY
TYPE
Ventilation, Exhaust ,Pressurization & smoke extraction
Requirements:
• To supply oxygen for breathing (respiration).
• To dilute pollutants such as body odors and
exhaled carbon dioxide.
• To remove unwanted heat from the building.
• To supply air for combustion appliances
• To lower the relative humidity and so avoid
condensation.
• To clear smoke in the event of fire.
CAR PARKING SCHEMATIC
CFD ANALYSIS
SCHEMATIC SECTOIN OF STAIRCASE PRESSURIZATION
• FIRE FIGHTING SYSTEM
FIRE FIGHTING SYSTEM CONSIST OF :
• HYDRANT SYSTEM (INTERNAL & EXTERNAL)
• AUTOMATIC SPRINKLER SYSTEM
• FIRE PUMPS
• FIRE WATER RESERVOIR
• PORTABLE FIRE EXTINGUISHERS
• WATER CURTAINS
APPLICATION DESIGN STANDARD AND CODES
The National Building Code (NBC) and Local Fire Authority together form the basis
for the fire protection design.
NFPA 13 - Standard for the Installation of Automatic Sprinkler Systems.
NFPA 14 - Standard for the Installation of Standpipe Systems - 2003 edition.
Recommendations of the local CFO.
• HYDRANT SYSTEM
INTERNAL EXTERNAL
• AUTOMATIC SPRINKLER SYSTEM
• FIRE PUMPS
• FIRE WATER RESERVOIR
• PORTABLE FIRE EXTINGUISHERS
• WATER CURTAINS
• TYPICAL FIRE PROTECTION SCHEMATIC
MUNCIPAL WATER SUPPLY TANKER WATER /BOREWELL
BRIDGE INLET FIRE WATER TANK
DP HP SP J B
HYDRANT SPRINKLER
DP : Diesel Pump
HP : Hydrant Pump EXTERNAL HYDRANT INTERNAL HYDRANT
SP : Sprinkler Pump
J : Jockey Pump
B : Booster Pump
PLUMBING SYSTEM
THE PLUMBING SYSTEM IS REALLY MADE UP OF TWO SYSTEMS:
The supply system that brings in fresh water
The drain-waste-vent system that takes out used water and
sewage
• THE DRAIN-WASTE-VENT SYSTEM ALSO LETS AIR IN AND WASTE
• GASES OUT.
• BETWEEN THESE TWO SYSTEMS ARE THE FIXTURES (SINKS,
TUBS, TOILETS, AND SO ON).
DESIGN STANDARD AND CODES
IS 5329 – 1983 Code of practice for sanitary pipe work above ground for buildings
IS 2064 – 1973 Code of practice for selection, installation and maintenance of sanitary appliances
IS 1239 Part 1 & Part 2 Steel tubes & tubulars and fittings
IS 783 – 1959 Code of practice for laying of concrete pipes
IS 2527 – 1984 Code of practice for fixing rainwater gutters and down pipes for roof drainage
IS 6784 – 1984 Method of performance testing of water meters (Domestic type)
IS 12235 (Parts 1to11) Methods of test for un plasticized PVC pipes
IS 458 – 1988 Specification for pre-cast concrete pipes (with or without reinforcement)
IS 771 – (Part 3to6) Specific requirements for urinals
IS 2548 (Part 1&2) Specification for plastic seats and covers for water closets
IS 3004 – 1979 Specification for plug cocks for water supply purposes
IS 1703 – 1977 Specification for ball valves (Horizontal plunger type) including floats for water supply purposes
IS 4038 – 1979 Specification for foot valves for water works purposes
IS 1172 – 1983 Code of basic requirements for water supply, drainage & sanitation
IS : 3989 Centrifugally cast iron pipes
IS : 13592 PVC SWR Pipes & Fittings
IS 1726 – 1991 Code for cast iron manhole frame and cover
IS 1742 – 1983 Code of practice for building drainage
IS 2064 – 1973 Code of practice for selection, installation and maintenance of sanitary appliances
IS 2065 – 1983 Code of practice for water supply to buildings
IS 4111 – 1986 Code of practice for Ancillary structures in sewerage system
IS 4985 – 1988 Specification for un plasticized PVC pipes
IS 778 Specification for gunmetal gate, globe and check valves for water, steam and oil only
PHE Services
Water Storage
Water Pumping and Distribution Supply System
Sewage Treatment Plant
Water Treatment
Rain Water Harvesting
• WATER STORAGE
Water Pumping and Distribution Supply System
WATER DISTRIBUTION SYSTEM
DOMESTIC FLUSHING
HYDRO HYDRO
GRAVITY GRAVITY
PNEUMATIC PNEUMATIC
SCHEMATIC DOMESTIC WATER SUPPLY SYSTEM
MUNCIPAL WATER SUPPLY TANKER WATER/BOREWELL
FIRE TANK
OVERFLOW FROM FIRE
TANK
RAW WATER TANK
WTP
DOMESTIC WATER TANK
TOILETS& PANTRY/KITCHEN
SCHEMATIC FLUSHING WATER SYSTEM
SEWAGE FROM TOILET PANTRY/ KITCHEN
INSPECTION CHAMBER GREASE TRAP
STP
TREATED WATER WASTE WATER
FLUSHING WATER TANK DISPOSAL TO MUNICIPAL LINE
FLUSHING WATER FOR TOILETS
SEWAGE TREATMENT PLANT
RAIN WATER HARVESTING
ELECTRICAL SYSTEM
REFERENCE STANDARD OF ELECTRICAL
• Local By – laws
• National Building Code of India – 2005 / Draft
NBC 2015
• Energy Conservation Building Codes 2009
• Relevant codes of Bureau of Indian Standards
• Institute of Electrical & Electronic Engineers
(Design Hand Book)
• NEC – NFPA 70, National Electric Code
• NFPA 101, Life safety code
• NEC, National Electric Code of India
• Indian Electrical Act
• Indian Electrical Rule
ELECTRICAL SYSTEM
TRANSFORMERS LT PANELS
ELECTRICAL SYSTEMS
HT PANELS DISTRIBUTION BOARDS
METERING EARTHING
BUSDUCT/CABLING CABLE TRAY
EXTERNAL INTERNAL
EARTHPIT/EARTHING LT CABLING
POWER/ LIGHTING
LIGHTING ARRESTORS WIRING
CLASSIFICATION OF UPS/EMERGENCY
DG SETS ELECTRICAL SYSTEMS WIRING
RECEPTACLES
SOLAR SYSTEM
LUMINAIRES
ELECTRICAL SCHEMATIC
FROM UTILITY
HT INCOMING SUPPLY
HT CABLE
METERING KIOSK
HTCABLE
HT PANEL
HTCABLE
TRANSFORMERS DG SETS
BUS DUCTS / CABLES
LT PANELS
CABLES BUSDUCTS/ CABLES
CAPACITOR DISTRIBUTION
UPS
BANKS BOARDS
LIGHTING POWER Common area
EXTRA VOLTAGE SYSTEM
• FIRE ALARM SYSTEM
• PUBLIC ADDRESS SYSTEM
• CCTV SYSTEM
• ACCESS CONTROL SYSTEM
• BUILDING MANAGEMENT SYSTEM
FIRE ALARM SYSTEM
PUBLIC ADDRESS SYSTEM
PUBLIC ADDRESS SYSTEM
CCTV SYSTEM
ACCESS CONTROL SYSTEM
BUILDING MANAGEMENT SYSTEM
BHAVIK PANCHAL
Contact us:
Bhavik Panchal
Qualification:(Diploma & BE in electrical & Post gradutae
diploma in Energy management ,PDGEM )
Experience: 8 years of experience in the MEP installation of
Residential ,commercial ,Hotel ,hospital & Industrial project
Mobile /What sapp no: 8286401135
THANK YOU