IV- AUMA 1
ELECTRIC ACTUATOR AUMA SA 07.2÷16.2
Multi-turn actuator for the CLOSED-OPEN function;
Electric engine, with three-phase operation ( one phase operation), with
induction winding cage, insolation class F, with three thermistors wrapped in
Design: stator’s coils for overload protection.
Cycle: S2-15 min.
2 limit switches and 2 moment switches.
Wheel for manual operation in case of emergency with hand lever for
triggering and automatically disconnecting the mechanism at engine turn-on.
Wiring diagram KMS.
Water protection IP67 according to EN60529
Standard coating SILVER GREY ( similar to RAL 9007)
Environment -25˚C and up to +80˚C
temperature:
Connecting According to DIN ISO 5210.
flange:
220V;230V;380V;400V;500V
Power 50HZ ( for the three-phase alternative power engines)
supply: 220V;240V;50Hz ( for the one-phase alternative power engines)
24VDC ( continuous power)
Protection IP 67
IP58 protection
Mechanical position indicator
Potentiometer 4÷20mA
Thermistors PTC ( according to DIN 44082)
Optional: Cycle: S2-30min.
Tandem moment and cycle limiter ( 2NC and 2NO for each direction)
Explosion protection: II2G Eex IIC T4
Control panel AUMA MATIC
Control panel AUMATIC
Body, Caps, wheel: Aluminium alloy
Internal parts: Steel, Bronze alloy, Stainless Steel
Drive bush, gear cogs, pinions Carbon steel
IV- AUMA 1
IV- AUMA 1
Local control
OPEN-STOP-CLOSED buttons and indicating lamps ( OPEN-green light; DAMAGE- red light,
CLOSED- yellow light)
Selective switch LOCAL-CLOSED-DISTANCE ( Lockable in all three positions)
Reversing contactor switch with mechanical and electrical stopping devices.
Entry/Exit signals.
Entry signal OPEN – (STOP)-CLOSED at 24V cc from internal or external power source.
Exit signal for the limit positions CLOSED/OPEN and selective switch in the
LOCAL/DISTANCE position.
Warning signal with control relay ( phase warning, engine protection launched at half
cycle)
Logical programmed control
Automatic phase correction
Power supply panel with control transformer at 24V cc
Wiring diagram MSP 1110 KC3-A18E1 KMS TP 114/001
Water protection IP67 according to EN60529
Standard coating Silver-Grey ( similar to RAL 9007)
Working environment temperature: -20˚C up to 40˚C
Power supply connector with sealed terminal panel with double inside sealing and with an
entry bonnet for 3 wires (2xM25x1,5 and 1xM20x1,5)
Local control
OPEN-STOP-CLOSED buttons and indicating lamps ( OPEN-green light; DAMAGE- red light,
CLOSED- yellow light)
Selective switch LOCAL-CLOSED-DISTANCE ( Lockable in all three positions) with double
contacts for distance indication
Signal for collective damage through monitoring relay ( phase warning, engine protection
launched at half cycle)
Logical programmed control
Automatic phase correction
Auto-adaptable positioner ( optional)
Programmable signal relays
Communication interface PROFIBUS or MODBUS
Alfa-numerical display
Monitoring and diagnostic
Registration of functioning data
Serial programming interface
Power supply control panel with 24Vcc transformer
Wiring diagram MSP 111700-F28E1 KMS TP104/201
Water protection IP67 according to EN60529
Standard coating Silver-Grey ( similar to RAL 9007)
Working environment temperature: -25˚C up to 60˚C
Power supply connector with terminal panel with an entry bonnet for 3 wires (2xM25x1,5
and 1xM20x1,5)