100% found this document useful (1 vote)
432 views

SA12A90 - F10 Data Sheet On-Off

This document provides specifications for an SA12A90 actuator with integral starter to be used for valves tagged 21HFY30AA151 through 22HFY80AA151. The actuator has a torque range of 40-120 Nm, operates at 90 RPM, and is rated for S2-15 minute duty cycle with a maximum of 60 starts per hour. Key electrical specifications include 415V 3-phase 50Hz power, IP67 enclosure, and thermal switches. The actuator weighs approximately 49kg.

Uploaded by

anbarasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
432 views

SA12A90 - F10 Data Sheet On-Off

This document provides specifications for an SA12A90 actuator with integral starter to be used for valves tagged 21HFY30AA151 through 22HFY80AA151. The actuator has a torque range of 40-120 Nm, operates at 90 RPM, and is rated for S2-15 minute duty cycle with a maximum of 60 starts per hour. Key electrical specifications include 415V 3-phase 50Hz power, IP67 enclosure, and thermal switches. The actuator weighs approximately 49kg.

Uploaded by

anbarasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MKTG/AUMA-IV/15-16 Rev 00

12/23/2015
DATA SHEET
Page 1 of 1

Project : M/s. MEPL


22HFY30AA151, 22HFY40AA151, 22HFY50AA151,
Valve Tag Nos. :
22HFY60AA151, 22HFY70AA151, 22HFY80AA151
21HFY30AA151, 21HFY40AA151, 21HFY50AA151,
21HFY60AA151, 21HFY70AA151, 21HFY80AA151
Actuator : SA12A90
DATA SHEET FOR ACTUATOR WITH INTEGRAL STARTER (EPAC) – ON-OFF TYPE
Actuator Model:- SA12A90
Description Unit Data
Manufacturer Auma India
Actuator Model- flange SA12A90 – F10
Torque range of Actuator only Nm Min.40 – Max.120
Actuator Speed RPM 90
ISO Flange Std. / Max. shaft Diameter F10 / 38 mm
Type of service ON-OFF
Duty S2-15 mins.
No. of Starts per Hour (Max) 60 st/hr.
Enclosure IP67
Motor type & reference standard Squirrel cage induction motor & IS325
Rated Voltage and Frequency 415 Volts, 50 Hz, 3Ph, AC
Admissible Voltage Fluctuation % +/-10
Admissible Frequency Fluctuation % +/- 5
Admissible Voltage and Frequency Variation % 10 (absolute)
Insulation Class ‘F’ class with temp. rise limited to Class ‘B’
0
Admissible ambient temperature C -20 to +80
Cable entries 2XM20X1.5 & 1XM32X1.5
Lubrication Grease – EP0 Servogem
4 nos. 2NO+2NC contacts
Limit switches
(2 for OPEN & 2 for CLOSE)
2 nos. 2NO+2NC contacts
Torque switches
(1 for Open and 1 for Close)
Rating of switches 5A/0.46A at 250V AC/DC
Thermo switches 3 nos. (one in each winding)
Local Position Indication Continuous Local Mechanical Position Indicator
Hand wheel Top Mounted for manual operation
Space Heater Yes (Internally powered)
TOLR Yes
Motor nominal output kW 1.1
Frame size 71
Full Load Current/Nominal Current A 2.9
Starting Current A 16
Full load speed rpm 2800
Power factor 0.72
Full load efficiency % 75
Paint Shade Smoke.Grey Paint shade 692 of IS 5
Wiring Diagram No. 3-WDP-A2D ; ZDAA101A-B6B00
Weight of Actuator (Approx) only Kgs 49 (approx)

Prepared by PK
Auma (India) Pvt. Ltd.,
Approved by PK

You might also like