The document describes the SensoIRIS addressable fire alarm system, including an addressable fire panel, loop expanders, programming and monitoring software, detectors, bases, call points, modules, addressing tools, and audio-visual devices. The system supports up to 4 loops with 250 devices per loop, has a touchscreen display, 10,000 event log, and can connect 32 panels in an Ethernet network. Detectors have selectable sensitivity levels and classes, and include heat, smoke, and combined models. Modules provide inputs, outputs, and interfaces to conventional systems. Audio devices include wall sounders, bases with sounders, and models with strobe lights.

Uploaded by

Ahcene
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
113 views

CNC Retrofit Kit

The document describes the SensoIRIS addressable fire alarm system, including an addressable fire panel, loop expanders, programming and monitoring software, detectors, bases, call points, modules, addressing tools, and audio-visual devices. The system supports up to 4 loops with 250 devices per loop, has a touchscreen display, 10,000 event log, and can connect 32 panels in an Ethernet network. Detectors have selectable sensitivity levels and classes, and include heat, smoke, and combined models. Modules provide inputs, outputs, and interfaces to conventional systems. Audio devices include wall sounders, bases with sounders, and models with strobe lights.

Uploaded by

Ahcene
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SensoIRIS

Addressable Fire Alarm Solution

Addressable Fire Alarm Panel

IRIS - Addressable Fire Panel


• Expandable from 1 to 4 loops;
• 96 zones;
• 10 000 events log;
• Touch-screen display;
• Multi-language menus;
• Supports TTE and System Sensor protocols;
• Up to 250 devices per each loop;
• 4 operation levels for optical detectors:
low/ middle/ normal/ high;
• Day and night operation modes;
• Selectable classes for heat detectors:
A1R, A2R, BR, A1S, A2S, BS, CS;
• Up to 32 panels connected in Ethernet network;
• External printer interface;
• Optional redundant processor;
• ModBUS over Ethernet interface;
• Operation with 1 accumulator battery 12V/18Ah.
EN54-2/4

IRIS Loop Expanders


IRIS TTE loop IRIS SS loop
• Loop expander for 1 loop; • Loop expander for 1 loop;
• Supports ТTE protocol; • Supports System Sensor 200/500 pro-
• Maximum consumptions of the loop tocol;
devices - 500mA; • Maximum consumptions of the loop
• Maximum number of devices in the devices - 500mA;
loop - 250. • Maximum number of devices in the
loop - 198: 99 detectors + 99 devices
(modules, sirens and call points).

Software Applications
ProsTE - Programming Software
• Programming software for products manufactured by Teletek Electronics JSC;
• Quick and easy operation with user-friendly graphic interface;
• Multi-language menus;
• Possibility for creating of data base with different system configuration;
• Reading and writing system configurations via special cable.

Alvis - Monitoring Software


• A general-purpose tool to develop user specific monitoring and control system;
• Suitable for monitoring and control of small and large protected areas;
• No limitation of sort, quantity, producer the way of connection of devices;
• Based on client-server architecture, allowing distributed division of the alarm
and monitored system among several computers interconnected in a network;
• The monitored panels can be connected to different computers and their
operation can be controlled by another computer.
Addressable Fire Alarm Detectors
SensoIRIS T110 / T110IS - Addressable Heat Detector
• Class, selectable from the control panel: A1R, A2R, BR, A1S, A2S, BS, CS;
• Power supply: 15 - 30VDC;
• Consumption in quiescent state: T110 < 180μA; Т110IS < 290μA;
• Consumption in alarm state: 6.5mA;
• Protected area: up 35m²;
• Installation height: up 3,5m;
• Supports TTE protocol. EN54-5
• SensoIRIS T110IS is with built-in isolator module.

SensoIRIS S130 / S130IS - Addressable Smoke Detector


• Sensitivity, selectable from the control panel: High/ Normal/ Middle/ Low;
• Power supply: 15 - 30VDC;
• Consumption in quiescent state: S130 < 200μA; S130IS < 310μA;
• Consumption in alarm state: 6.5mA;
• Protected area: up 120m²;
• Installation height: up 16m;
• Supports TTE protocol. EN54-7
• SensoIRIS S130IS is with built-in isolator module.

SensoIRIS M140 / M140IS - Combined Heat and Smoke Detector


• Class: A1/R;
• Sensitivity, selectable from the control panel: High/ Normal/ Middle/ Low;
• Power supply: 15 - 30VDC;
• Consumption in quiescent state: M140 < 200μA; M140IS < 310μA;
• Consumption in alarm state: 6.5mA;
• Protected area: up 120m²;
• Installation height: up 16m;
• Supports TTE protocol. EN54-5/7
• SensoIRIS M140IS is with built-in isolator module.

Bases
SensoIRIS B124 - Standard Base
• Compatible with addressable fire detectors:
SensoIRIS T110/ T110IS, SensoIRIS S130/ S130IS, SensoIRIS M140/ M140IS;
• Low profile design;
• Reliable contact system;
• Possibility of locking the detector to the base.

Addressable Call Points


SensoIRIS MCP150
• Resettable fragile (flexible) element;
• LED indication for fire alarm event;
• Supports TTE protocol;
• Built-in isolator module;
• Optional transparent cover.
EN54-11
Addressable Modules
SensoIRIS MIO - Input/ Output Module
• Range of modules with inputs and outputs;
• Built-in isolator module;
• Status LED indication;
• Supports TTE protocol;
• Mounting box - IP67.
EN54-18

SensoIRIS MC-Z - Conventional Zone Module


• Provides interface between a zone of conventional detectors and IRIS TTE Loop;
• Built-in isolator module;
• Status LED indication;
• Supports TTE protocol;
• Mounting box - IP67.
EN54-18

SensoIRIS MOUT - Output Module


• Potential output for conventional sounders;
• Built-in isolator module;
• Status LED indication;
• Supports TTE protocol;
• Mounting box - IP67.
EN54-18

SensoIRIS MC-D - Conventional Detectors Module


• Addressable base for conventional detectors SensoMAG series;
• Loop powered;
• Supports TTE protocol. EN54-18

SensoIRIS MISO - Isolator Module


• Compact mounting box - IP40;
• Supports TTE protocol. EN54-17

SensoIRIS MINP - Mini Input Module


• Provides connection of external control devices;
• Compact size, suitable for built-in mounting;
• Supports TTE protocol.
EN54-18

Addressing Tools
SensoIRIS Programmer
• Compatible with addressable detectors and modules SensoIRIS series;
• Supports TTE protocol;
• Easy address programing;
• LCD screen for viewing the operation.

Teletek Electronics JSC, www.teletek-electronics.com


Addressable Audio-Visual Devices
SensoIRIS WSOU - Wall Sounder
• Wall mount sounder;
• 2 sound levels selectable from the panel - 92dB/ 100dB;
• 32 sound types selectable from the panel; in
• Loop powered; o m ing 2
C 01
• Color - red;
Q of 2
• Supports TTE protocol; 3
• Optional built-in isolator;
• In compliance with EN54-3.

SensoIRIS WSST - Wall Sounder and Strobe


• Wall mount sounder and strobe;
• 2 sound levels selectable from the panel - 92dB/ 100dB;
in
• 32 melody types selectable from the panel;
o m ing 2
C 1
• Loop powered;
o f 20
• Color - red, transparent; 3Q
• Supports TTE protocol;
• Optional built-in isolator;
• In compliance with EN54-3.

SensoIRIS BSOU - Base with Sounder


• Base with built-in sounder;
• 2 sound levels selectable from the panel - 92dB/ 100dB; n
• 32 melody types selectable from the panel; m i ng i 3
• Loop powered; Co f 201
o
• Color - white; 1Q
• Supports TTE protocol;
• Optional built-in isolator.

SensoIRIS BSST - Base with Sounder and Strobe


• Base with built-in sounder and strobe;
n
ng i 3
• 2 sound levels selectable from the panel - 92dB/ 100dB;
• 32 melody types selectable from the panel; m i
Co f 201
• Loop powered; o
• Supports TTE protocol; 1Q
• Optional built-in isolator;
• In compliance with EN54-3.

Contact Information
Address: 14A Srebarna Str., 1407 Sofia, Bulgaria
Tel.: (+359) 2 96 94 800, 2 96 94 744; Fax: (+359) 2 96 25 213
e-mail: [email protected]; www.teletek-electronic.com

02 / 2012

You might also like