A reinforced concrete spandrel beam has overall dimensions of 250 x 460 and is joined
integrally with a 150 mm slab as shown in Fig. 1. The section shown is that at the critical location a
distance d from the face of support. At this section, the factored loads are negative bending moment M u
= 100 kN-m, shear force Vu = 89 kN, and torsional moment Tu = 11 kN-m. Assume that the torsional
stiffness was estimated and used in a structural analysis to obtain these design loadings. Check the
adequacy of this section, and select the transverse hoop steel required, if any, according to ACI Code
using f’c = 28 MPa and fy = 276 MPa. 10 mm @
100 mm o.c.
150 mm 3-25 mm
3-25 mm
460 mm
d = 400 mm
10 mm @ 2-16 mm 10 mm minimum
100 mm o.c. size, slab design will
2-20 mm
2-20 mm determine this
reinforcement
250 mm 3hf = 450 mm
(a) Details of torsion reinforcement
(b) Given data
Fig. 1 Spandrel beam of Example
1 2mRn fy 276
required = 1 1 m= '
= = 11.597
m fy 0.85 f c 0.85(28)
1 2(11.597)( 2.778)
required = 1 1 = 0.010733
11.597 276
Acp2
limit Tu 0.083 f '
Pcp
c
Note that Acp, the area enclosed by outside perimeter of the concrete section, and Pcp, the outside
perimeter of the concrete cross-section, have included the slab portion. Note that the maximum
effective width of slab used is 3 times its thickness (ACI-R11.6.1, 4th par.). That ACI Commentary section
states, “For a T-beam cast monolithically with a slab, Acp and Pcp can include portions of the adjacent
slabs conforming to 13.2.4.” Unless closed stirrups are used in the slab portion, that area should not be
included in computing either Acp or Pcp. Thus
182500 2
limit Tu 0.083(0.75)(1.0) 28 = 4728856.379 N-mm = 4.729 kN-m
2320
(c) Determine whether or not the section is large enough for combined shear and torsion. From ACI-
11.6.3.1, for solid sections
2 2
Vu Tu Ph Vc
2
0.66 f ' c
w
b d 1.7 Aoh w
b d
Conservatively, the effect of the integral slab is neglected. The perimeter Ph of the centerline of
outermost closed transverse torsional reinforcement, again neglecting the integral slab,
Since 2.7445 MPa exceeds 2.15 MPa, the section has adequate size.
2 Ao At f yt
Tn = cot (ACI 11.21)
s
At 14.667 x10 6
= 0.528 mm2/mm for 1 leg of stirrup
s 2(50320)( 276) cot( 45 o )
Av/s = Vs/fyd = (28711 N)/[276(400)] = 0.26 mm2/mm for two legs of stirrups
2At/s + Av/s = 2(0.528) + 0.26 = 1.316 mm2/mm for two legs of stirrups
Taking, s = 100 mm
Stirrups provided are 10 mm bars spaced at 100 mm o.c.
At f yt 2
Al= ph cot = ( 0.528)(1060 mm)(276/276)(1)2557.56 mm2
s f
y
Additional longitudinal steel is provided in four inside corners of stirrups and vertically in
between. So, total longitudinal steel provided in beam is,
Try 2-16 mm bars for the mid-depth reinforcement, As = 2(π/4)(16)2 = 402.124 mm2
Available As provided:
3-25 mm
10 mm @ 2-16 mm 10 mm minimum
100 mm o.c. size, slab design will
2-20 mm determine this
reinforcement
Details of torsion reinforcement