0% found this document useful (0 votes)
731 views7 pages

Slab Corridor

1) The document provides specifications for the design of a reinforced concrete slab, including geometry, materials, actions, and structural requirements. 2) The minimum required slab thickness is 80mm for fire resistance. The estimated thickness for deflection control is 61.5mm, but a thickness of 150mm is selected. 3) Main reinforcement is determined to be H10 bars with 262mm^2/m at the bottom of short spans and 314mm^2/m at the top of short spans. Long span reinforcement is H10 bars with 262mm^2/m at the top.

Uploaded by

Tin Nesalaeh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
731 views7 pages

Slab Corridor

1) The document provides specifications for the design of a reinforced concrete slab, including geometry, materials, actions, and structural requirements. 2) The minimum required slab thickness is 80mm for fire resistance. The estimated thickness for deflection control is 61.5mm, but a thickness of 150mm is selected. 3) Main reinforcement is determined to be H10 bars with 262mm^2/m at the bottom of short spans and 314mm^2/m at the top of short spans. Long span reinforcement is H10 bars with 262mm^2/m at the top.

Uploaded by

Tin Nesalaeh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 7

REF.

CALCULATIONS OUTPUT
Corridor, 2-3/A-B

SPECIFICATION:

A B
Ly = 5100
2

Lx = 1600

Characteristics Action:
𝑙𝑦 5100
Long span, 𝑙𝑦 = 5100 𝑚𝑚 = = 3.18 > 2.0
𝑙𝑥 1600
Short span, 𝑙𝑥 = 1600 𝑚𝑚 ∴ 𝐨𝐧𝐞 𝐰𝐚𝐲 𝐬𝐥𝐚𝐛

Characteristic actions:
 Permanent, 𝑔𝑘 = 1.75 𝑘𝑁/𝑚2 (excluding selfweight)
 Variable, 𝑞𝑘 = 3.0 𝑘𝑁/𝑚2
 Design life = 50 𝑦𝑒𝑎𝑟𝑠 (Table 2.1 EN 1990)
 Fire resistance = 𝑅60 (Sec. 5.7 EN 1992-1-2)
Table 4.1  Exposure classes = 𝑋𝐶1

Materials:
 Characteristic strength of concrete, 𝑓𝑐𝑘 = 30 𝑁/𝑚𝑚2
 Characteristic strength of steel, 𝑓𝑦𝑘 = 500 𝑁/𝑚𝑚2
 Unit weight of reinforced concrete = 25 𝑘𝑁/𝑚3
 Assumed: ∅𝑏𝑎𝑟 = 10 𝑚𝑚

SLAB THICKNESS
Table 5.8 EN
Minimum thickness for fire resistance = 80 𝑚𝑚 1992-1-2
Table 7.4N Estimated thickness considering deflection control:
1600
ℎ= = 61.5 𝑚𝑚
26 Try,
𝒉 = 𝟏𝟓𝟎 𝒎𝒎
DURABILITY, FIRE AND BOND REQUIREMENTS:

Table 4.2 Min. cover with regard to bond, 𝐶𝑚𝑖𝑛,𝑏 = 10 𝑚𝑚


Table 4.4N Min. cover with regard to durability, 𝐶𝑚𝑖𝑛,𝑑𝑢𝑟 = 15 𝑚𝑚
4.4.1.2 Min. required axis distance for 1.0 hour fire resistance: Table 5.8 EN
1992-1-2
𝑎 = 20 𝑚𝑚
Min. cover with regard to fire:
∅ 10
𝐶𝑚𝑖𝑛,𝑓𝑖𝑟𝑒 = 𝑎 − 𝑏𝑎𝑟 = 20 − = 15 𝑚𝑚
2 2
4.4.1.3 𝑪𝒎𝒊𝒏 = 𝟏𝟓 𝒎𝒎
Allowance in design for deviation, ∆𝐶𝑑𝑒𝑣 = 10 𝑚𝑚
4.4.1.1(2) Nominal cover:
𝑪𝒏𝒐𝒎 = 𝟐𝟓 𝒎𝒎
𝐶𝑛𝑜𝑚 = 𝐶𝑚𝑖𝑛 + ∆𝐶𝑑𝑒𝑣 = 15 + 10 = 25 𝑚𝑚

ACTIONS:

Slab self-weight = 0.150 × 25 = 3.75𝑘𝑁/𝑚2


Ceramic tiles = 1 𝑘𝑁/𝑚2
Cement render = 0.3 𝑘𝑁/𝑚2
Ceiling = 0.15 𝑘𝑁/𝑚2
Building services = 0.3 𝑘𝑁/𝑚2
Permanent load (excluding self-weight), 𝑔𝑘 = 1.75 𝑘𝑁/𝑚2 Table A1.2B : EN
Characteristic permanent action, 𝑔𝑘 = 3.75 + 1.75 1990
= 5.5 𝑘𝑁/𝑚2
Characteristic variable action, 𝑞𝑘 = 3.0 𝑘𝑁/𝑚2
Design action, 𝑛𝑑 = 1.35𝑔𝑘 + 1.5𝑞𝑘
= 1.35(5.5) + 1.5(3.0) = 11.93 𝑘𝑁/𝑚2

ANALYSIS:
Bending moment:
Continue
𝑤𝑑 𝐿2 (11.93)( ) from here
𝑀= =
12
Short span,
𝑚𝑠𝑥1 = 𝛽𝑠𝑥 𝑛𝑑 𝑙𝑥 2 = 0.05(11.93)1.602 = 11.10 𝑘𝑁𝑚/𝑚
𝑚𝑠𝑥2 = 𝛽𝑠𝑥 𝑛𝑑 𝑙𝑥 2 = 0.063(11.93)1.602 = 13.97 𝑘𝑁𝑚/𝑚

Long span,
𝑚𝑠𝑦 = 𝛽𝑠𝑦 𝑛𝑑 𝑙𝑥 2 = 0.037(11.93)1.602 = 8.21 𝑘𝑁𝑚/𝑚
MAIN REINFORCEMENT:

Effective depth:
𝑑 = ℎ − 𝐶𝑛𝑜𝑚 − 0.5∅𝑏𝑎𝑟 = 150 − 25 − 0.5(10) = 120𝑚𝑚

9.2.1.1 Minimum and maximum reinforcement area:


𝐴𝑠,𝑚𝑖𝑛 = 0.0013𝑏𝑑 = 0.0013(1000)(120) = 160𝑚𝑚2 /𝑚 Secondary bar,
𝐴𝑠,𝑚𝑎𝑥 = 0.04𝑏ℎ = 0.04(1000)(150) = 6000𝑚𝑚2 /𝑚 H10-300
(262 𝒎𝒎𝟐 /𝒎)

Short span:

6.1 - Mid span, 𝑚𝑠𝑥1 = 11.10 𝑘𝑁𝑚/𝑚

𝑀
𝑘=
𝑓𝑐𝑘 𝑏𝑑 2
11.10(106 )
𝑘= = 0.031 < 𝑘𝑏𝑎𝑙 = 0.167
25(1000)(120)2

∴ 𝒄𝒐𝒎𝒑𝒓𝒆𝒔𝒔𝒊𝒐𝒏 𝒊𝒔 𝒏𝒐𝒕 𝒓𝒆𝒒𝒖𝒊𝒓𝒆𝒅 OK!

𝑘
𝑧 = 𝑑 [0.5 + √(0.25 − )]
1.134

0.031
𝑧 = 𝑑 [0.5 + √(0.25 − )]
1.134
𝑧 = 0.97𝑑 > 0.95𝑑 = 0.95(120) = 114

∴ 𝒕𝒂𝒌𝒆 𝒛 = 𝟏𝟏𝟒

𝑀 11.10(106 ) 𝑼𝒔𝒆,
𝐴𝑠 = = = 224 𝑚𝑚2 /𝑚
0.87𝑓𝑦𝑘 𝑧 0.87𝑥500𝑥114 𝑯𝟏𝟎 − 𝟑𝟎𝟎
(𝟐𝟔𝟐𝒎𝒎𝟐 /𝒎)
Bottom
6.1 - Support, 𝑚𝑠𝑥2 = 13.97 𝑘𝑁𝑚/𝑚

𝑀
𝑘=
𝑓𝑐𝑘 𝑏𝑑 2
13.97(106 )
𝑘= = 0.039 < 𝑘𝑏𝑎𝑙 = 0.167
25(1000)(120)2

∴ 𝒄𝒐𝒎𝒑𝒓𝒆𝒔𝒔𝒊𝒐𝒏 𝒊𝒔 𝒏𝒐𝒕 𝒓𝒆𝒒𝒖𝒊𝒓𝒆𝒅 OK!

𝑘
𝑧 = 𝑑 [0.5 + √(0.25 − )]
1.134

0.039
𝑧 = 𝑑 [0.5 + √(0.25 − )]
1.134
𝑧 = 0.96𝑑 > 0.95𝑑 = 0.95(120) = 114

∴ 𝒕𝒂𝒌𝒆 𝒛 = 𝟏𝟏𝟒

𝑀 13.97(106 )
𝐴𝑠 = = = 282 𝑚𝑚2 /𝑚 𝑼𝒔𝒆,
0.87𝑓𝑦𝑘 𝑧 0.87𝑥500𝑥114
𝑯𝟏𝟎 − 𝟐𝟓𝟎
𝟑𝟏𝟒𝒎𝒎𝟐 /𝒎
Top
Long span:
6.1
-Support, 𝑚𝑠𝑦 = 8.21 𝑘𝑁𝑚/𝑚

𝑀
𝑘=
𝑓𝑐𝑘 𝑏𝑑 2
8.21(106 )
𝑘= = 0.023 < 𝑘𝑏𝑎𝑙 = 0.167
25(1000)(120)2

∴ 𝒄𝒐𝒎𝒑𝒓𝒆𝒔𝒔𝒊𝒐𝒏 𝒊𝒔 𝒏𝒐𝒕 𝒓𝒆𝒒𝒖𝒊𝒓𝒆𝒅 OK!


𝑘
𝑧 = 𝑑 [0.5 + √(0.25 − )]
1.134

0.023
𝑧 = 𝑑 [0.5 + √(0.25 − )]
1.134
𝑧 = 0.98𝑑 > 0.95𝑑 = 0.95(120) = 114

∴ 𝒕𝒂𝒌𝒆 𝒛 = 𝟏𝟏𝟒

𝑀 8.21(106 ) 𝑼𝒔𝒆,
𝐴𝑠 = = = 166 𝑚𝑚2 /𝑚
0.87𝑓𝑦𝑘 𝑧 0.87𝑥500𝑥114 𝑯𝟏𝟎 − 𝟑𝟎𝟎
= 𝟐𝟔𝟐𝒎𝒎𝟐 /𝒎
Top
SHEAR:

Vsx

Vsx

𝑉𝑆𝑋1 = 𝑉𝑆𝑋2 = 𝛽𝑣𝑥 𝑛𝑙𝑥


𝑉𝑆𝑋1 = 𝑉𝑆𝑋2 = 0.5(16.65)(3.65) = 30.40 𝑘𝑁/𝑚

Design shear force:


𝑉𝐸𝑑 = 30.40 𝑘𝑁

6.2.2 Design shear resistance:

𝑉𝑅𝑑,𝑐 = 0.12𝑘(100𝜌1 𝑓𝑐𝑘 )1/3 𝑏𝑑


𝑘 = (1 + √200/𝑑) ≤ 2.0
𝑘 = (1 + √200/120) ≤ 2.0
𝑘 = 2.29 > 2.0
∴ 𝒕𝒂𝒌𝒆 𝒌 = 𝟐. 𝟎
𝐴𝑠1 314
𝜌1 = = = 0.0026 ≤ 0.02
𝑏𝑑 1000(120)
1
𝑉𝑅𝑑,𝑐 = 0.12(2)(100(0.0026)25)3 (1000)(120)
𝑉𝑅𝑑,𝑐 = 53.75 𝑘𝑁

𝑉𝑚𝑖𝑛 = (0.035𝑘 3/2 𝑓𝑐𝑘 1/2 )𝑏𝑑


𝑉𝑚𝑖𝑛 = (0.035(2)3/2 (25)1/2 )(1000)(120) = 59.40 𝑘𝑁

∴ 𝑽𝑹𝒅,𝒄 > 𝑽𝑬𝒅 OK!

7.4 DEFLECTION :

Percentage of required tension reinforcement:

𝐴𝑠 𝑟𝑒𝑞 225
𝜌= = = 0.002
𝑏𝑑 1000(120)

Reference reinforcement ratio:


𝜌0 = √𝑓𝑐𝑘 10−3 = √25(10−3 ) = 0.005

Table 7.4N Factor for structural system, K=1.3

𝜌 < 𝜌0 𝑢𝑠𝑒 𝑒𝑞𝑢𝑎𝑡𝑖𝑜𝑛 (1)

𝑙 𝜌0 𝜌0 3/2
= 𝑘 [11 + 1.5√𝑓𝑐𝑘 + 3.2√𝑓𝑐𝑘 ( − 1) ]
𝑑 𝜌 𝜌
3/2
𝑙 0.005 0.005
= 1.3 [11 + 1.5√25 + 3.2√25 ( − 1) ]
𝑑 0.002 0.002

𝑙
= 1.3(11 + 12.4 + 8.45) = 41.40
𝑑

Modification factor:
 For span more than 7m
7
= = 0.96
7.3
 For steel area provided
𝐴𝑠,𝑝𝑟𝑜𝑣 262
= = 1.17 ≤ 1.5
𝐴𝑠,𝑟𝑒𝑞 224

Therefore allowable span-effective depth ratio:


𝑙
𝑎𝑙𝑙𝑜𝑤𝑎𝑏𝑙𝑒 = 41.40 × 0.96 × 1.17 = 46.50
𝑑

Actual span-effective depth:


𝑙 3650
𝑎𝑐𝑡𝑢𝑎𝑙 = = 30.40
𝑑 120

𝒍 𝒍 OK!
∴ 𝒂𝒄𝒕𝒖𝒂𝒍 < 𝒂𝒍𝒍𝒐𝒘𝒂𝒃𝒍𝒆
𝒅 𝒅

CRACKING:
7.3.3
ℎ = 150 𝑚𝑚 < 200 𝑚𝑚
9.3.1 Main bar:
𝑆𝑚𝑎𝑥,𝑠𝑙𝑎𝑏𝑠 = 3ℎ ≤ 400 𝑚𝑚
= 450 > 400 𝑚𝑚 , take 400 mm
𝑀𝑎𝑥. 𝑏𝑎𝑟 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 300 𝑚𝑚 < 𝑆𝑚𝑎𝑥,𝑠𝑙𝑎𝑏𝑠 OK!

Secondary bar:
𝑆𝑚𝑎𝑥,𝑠𝑙𝑎𝑏𝑠 = 3.5ℎ ≤ 450 𝑚𝑚
= 525 > 450 𝑚𝑚, take 450 mm OK!
𝑀𝑎𝑥. 𝑏𝑎𝑟 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 450 𝑚𝑚 < 𝑆𝑚𝑎𝑥,𝑠𝑙𝑎𝑏𝑠
DETAILING: