Eolo Maior KW 0093 GB
Eolo Maior KW 0093 GB
Wall-mounted boiler for heating and instantenaous production of adjuster knob, general selector with function (stand-by, domestic hot
domestic hot water, with sealed chamber, forced draught and 24 kW water, heating, Reset);
(20,640 kcal/h), 28 kW (24,080 kcal/h) or 32 kW (27,520 kcal/h) • boiler operating parameters entered by means of knobs with Leds to
nominal heat output, high efficiency and forced circulation. display the status and operating mode;
The boiler classification changes when the type of installation is varied, • check-control system with Leds to display the operating status and
regardless of whether the boiler is installed indoors or outdoors. faults;
Appliance type B22 - if installed using the relative kit (optional). • console with retracting controls complete with electronic board with
Appliance type C12/ C32/ C42/ C52/ C82 - if installed using the Ø 80/80 microprocessor, infinite flame modulation with 2 sensors (domestic
separator kit or concentric vertical or horizontal kits. hot water and heating), P.I.D. monitoring, modulation range:
Both models consist of: - EOLO Maior 24 kW from 9.3 to 24 kW (from 8,000 to 20,640
• main multigas burner with 11 ramps (mod. 24 kW), 14 ramps kcal/h);
(mod. 28 kW) or 15 ramps (mod. 32 kW) and aspirated air. Made - EOLO Maior 28 kW from 10.5 to 28 kW (from 9,000 to 24,080
of stainless steel and complete with ignition electrodes and detection kcal/h);
electrode; - EOLO Maior 32 kW from 12.5 to 32 kW (from 10,750 to 27,520
• electric gas valve with double shutter and built-in modulating coil; kcal/h);
• high-efficiency gas/water primary exchanger made of copper and • electronic ignition with ionizing monitoring function;
consisting of four pipes connected in series in lamellar coils protected • antifreeze protection system (down to -5 °C), circulator anti-blocking
by non-corroding alloy; function and three-way valve, system post-circulation function,
• combustion chamber in steel plate internally insulated with ceramic post-ventilation function, chimney-sweep function, pre-engineered
panels; for connection to the Immergas Amico Remote Control, the Timer-
• sealed chamber in steel plate with fixed speed fumes exhaust fan, thermostat, the Ambient thermostat, the Timer clock, the External
differential pressure switch to ensure the fan and fumes exhaust/air probe and the Electronic control unit for zoned systems;
intake circuit operate correctly; • IP X4D electrical insulation degree.
• secondary water/water exchanger for producing domestic hot water, • (optional) connecting group with depth adjustable fittings, gas cut
made of stainless steel with 16 plates (mod. 24 kW), 20 plate (mod. off cock and filling valve.
28 kW) or 22 plates (mod. 32 kW); Supplied complete with intakes for combustion analysis, bottom
• hydraulic unit consisting of a 3-way electric valve, adjustable speed protection grille.
circulator with built-in air separator, adjustable by-pass, absolute II2H3+ category appliance running on Natural Gas or LPG.. With
pressure switch for the primary circuit, system draining fitting and CE mark.
a cock for filling the system;
• domestic water flow switch to detect when domestic water is used; The following models are available:
• 10 litre diaphragm expansion tank (real capacity 7.4) with 1.0 bar • EOLO Maior 24 kW Export code 3.019355
preload, 3-bar system safety valve and pressure gauge; • EOLO Maior 28 kW Export code 3.019356
• overtemperature safety thermostat; • EOLO Maior 32 kW Export code 3.019357
• heating temperature adjuster knob, domestic hot water temperature
1
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
Wall-mounted boiler for heating and instantaneous production of preload, 3-bar system safety valve and pressure gauge;
domestic hot water, with sealed chamber, forced draught and 24 kW • overtemperature safety thermostat;
(20,640 kcal/h) or 28 kW (24,080 kcal/h) nominal heat output, high • heating temperature adjuster knob, domestic hot water temperature
efficiency and forced circulation. adjuster knob, general selector with function (stand-by, domestic hot
The boiler classification changes when the type of installation is varied, water, heating, Reset);
regardless of whether the boiler is installed indoors or outdoors. • boiler operating parameters entered by means of knobs with Leds to
Appliance type B22 - if installed using the relative kit (optional). display the status and operating mode;
Appliance type C12/ C32/ C42/ C52/ C82 - if installed using the Ø 80/80 • check-control system with Leds to display the operating status and
separator kit or concentric vertical or horizontal kits. faults;
both models consist of: • console with retracting controls complete with electronic board with
• main multigas burner with 11 ramps (mod. 24 kW) or 14 ramps microprocessor, infinite flame modulation with 2 sensors (domestic
(mod. 28 kW) and aspirated air. Made of stainless steel and complete hot water and heating), P.I.D. monitoring, modulation range:
with ignition electrodes and detection electrode; - EOLO Maior 24 kW VIP from 9.3 to 24 kW (from 8,000 to 20,640
• electric gas valve with double shutter and built-in modulating coil; kcal/h);
• high-efficiency gas/water primary exchanger made of copper and - EOLO Maior 28 kW VIP from 10.5 to 28 kW (from 9,000 to 24,080
consisting of four pipes connected in series in lamellar coils protected kcal/h);
by non-corroding alloy; • electronic ignition with ionizing monitoring function;
• combustion chamber in steel plate internally insulated with ceramic • antifreeze protection system (down to -5 °C), circulator anti-blocking
panels; function and three-way valve, system post-circulation function,
• sealed chamber in steel plate with fixed speed fumes exhaust fan, post-ventilation function, chimney-sweep function, pre-engineered
differential pressure switch to ensure the fan and fumes exhaust/air for connection to the Immergas Amico Remote Control, the Timer-
intake circuit operate correctly; thermostat, the Ambient thermostat, the Timer clock, the External
• secondary water/water exchanger for producing domestic hot water, probe and the Electronic control unit for zoned systems;
made of stainless steel with 16 plates (mod. 24 kW) or 20 plates • IP X4D electrical insulation degree.
(mod. 28 kW); • (optional) connecting group with depth adjustable fittings, gas cut
• patented "Aqua Celeris" comprising a small storage tank installed off cock and filling valve.
in the primary circuit and maintained at the right temperature by Supplied complete with intakes for combustion analysis, bottom
a modulating electric heating element; protection grille.
• hydraulic unit consisting of a 3-way electric valve, adjustable speed II2H3+ category appliance running on Natural Gas or LPG.. With
circulator with built-in air separator, adjustable by-pass, absolute CE mark.
pressure switch for the primary circuit, system draining fitting and
a cock for filling the system; The following models are available:
• domestic water flow switch to detect when domestic water is • EOLO Maior 24 kW VIP export code 3.019358
used; • EOLO Maior 28 kW VIP Export code 3.019359
• 8 litre diaphragm expansion tank (real capacity 6.5) with 1.0 bar
2
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
3
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
LEGEND:
1 - Gas valve 14 - Safety thermostat
2 - D.h.w. probe 15 - Flue hood
3 - D.h.w. flow switch 16 - Primary heat exchanger
4 - D.h.w. heat exchanger 17 - System expansion vessel
5 - Burner 18 - Ignition and detection electrodes
6 - Combustion chamber 19 - Automatic vent valve
7 - Sealed chamber 20 - Boiler pump
8 - Fan 21 - System pressure switch
9 - Sample point (air A) - (flues F) 22 - 3-bar safety valve
10 - Positive signal pressure point 23 - Three-way valve (motorized)
11 - Negative signal pressure point 24 - Draining valve
12 - Flue pressure switch 25 - Filling valve
13 - Flow probe
4
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
LEGEND:
1 - Gas valve 14 - Safety thermostat
2 - D.h.w. probe 15 - Flue hood
3 - D.h.w. flow switch 16 - Primary heat exchanger
4 - D.h.w. heat exchanger 17 - System expansion vessel
5 - Burner 18 - Ignition and detection electrodes
6 - Combustion chamber 19 - Aqua celeris
7 - Sealed chamber 20 - Automatic vent valve
8 - Fan 21 - Boiler pump
9 - Sample point (air A) - (flues F) 22 - System pressure switch
10 - Positive signal pressure point 23 - 3-bar safety valve
11 - Negative signal pressure point 24 - Three-way valve (motorized)
12 - Flue pressure switch 25 - Draining valve
13 - Flow probe 26 - Filling valve
5
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
LEGEND:
1 - Gas valve 12 - Flue hood
2 - Burner 13 - Primary heat exchanger
3 - Combustion chamber 14 - Ignition and detection electrodes
4 - Sealed chamber 15 - System expansion vessel
5 - Fan 16 - Automatic vent valve
6 - Sample point (air A) - (flues F) 17 - Boiler pump
7 - Positive signal pressure point 18 - System pressure switch
8 - Negative signal pressure point 19 - 3-bar safety valve
9 - Flue pressure switch 20 - Three-way valve plug
10 - Flow probe 21 - Draining valve
11 - Safety thermostat 22 - Filling valve
6
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
3.1 CONNECTIONS
B A B
A = inlet/outlet
B = inlet
Note: Coupling system (OPTIONAL) Distance between upper casing line and
Ø 80/80 separator elbow axis: A=135 mm B = 115
Model Flow Return Hot outlet Cold inlet Gas Expansion vessel
M R AC AF G Litres
EOLO Maior kW 3/4" 3/4" 1/2" 1/2" 1/2" 10 (real 7.4)
EOLO Maior kW VIP 3/4" 3/4" 1/2" 1/2" 1/2" 8 (real 6.6)
7
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
4.1 CONNECTIONS
B A B
A = inlet/outlet
B = inlet
Note: Coupling system (OPTIONAL) Distance between upper casing line and
Ø 60/100 concentric elbow axis: 95 mm
Water Heater Capacity Height Width Depth
UB 80 (80 l.) 850 mm 500 mm 500 mm Distance between upper casing line and
UB 105 (105 l.) 1020 mm 500 mm 500 mm Ø 80/80 separator elbow axis: A=135 mm B = 115
UB 120 (120 l.) 850 mm 600 mm 600 mm
UB 200 (200 litri) 1250 mm 600 mm 600 mm * Only if mounted Storage Tank coupling kit
Model Flow Return * Storage tank * Storage tank System filling Gas Expansion vessel
M R flow MU return RU RR G Litres
EOLO Maior kW X 3/4" 3/4" 3/4" 3/4" 1/2" 1/2" 10 (real 7.4)
8
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
“EOLO Maior kW” boilers are supplied with a built-in circu- The “EOLO Maior kW” boilers are equipped with an adju-
lation pump and three-position electric speed governor. The stable by-pass. The by-pass is regulated in the factory for curve
pump is already equipped with a condenser. B. This setting can be modified by means of the screw on the
by-pass unit.
Head (m H2O)
Head (kPa)
B A
A: Available head at top speed with by-pass closed (adjuster screw fully tightened).
B: Available head at top speed with factory setting (screw turned 1-1/2 turns in relation to the setting with the adjuster screw
fully loosened).
C: Available head at top speed with by-pass fully open (adjuster screw fully unscrewed).
9
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
Head (m H2O)
Head (kPa)
A: Available head at top speed with by-pass closed (adjuster screw fully tightened).
B: Available head at top speed with factory setting (screw turned 1-1/2 turns in relation to the setting with the adjuster
screw fully loosened).
C: Available head at top speed with by-pass fully open (adjuster screw fully unscrewed).
10
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
AMBIENT THERMOSTAT OR REMOTE CONTROL used, connect to terminals 40 and 41 and eliminate jumper
The boiler is pre-engineered for installation of the Amico Re- X40. If both are used, connect S20 to terminals 40 and 7
mote Control (CAR), which must be connected to terminals 42 and P1 to terminals 8 and 41 after having eliminated jumper
and 43 of connector X2 on the integrated electronic board, in X40.
compliance with the polarity and eliminating jumper X40. The External Probe (B4) must be connected to terminals 38
The boiler is pre-engineered for installation of the Ambient and 39 of connector X2 on the integrated electronic board.
Thermostat (S20) and Programmer Clock (P1). If only one is
Zone Control
Unit
230 Vac
50Hz
supply
brown
white
white
white
black
black
black
black
black
black
grey
blue
grey
grey
grey
grey
red
red
red
red
red
RELAY
BOARD
yellow/green
brown
blue
NAT-LPG
brown
blue
Primary
Secondary
LEGEND:
A5 - CAR interface board M30 - Three-way valve
B1 - Flow probe P1 - Heating Timer
B2 - D.h.w. probe R5 - D.h.w. temperature trimmer
B4 - External probe (optional) R6 - Heating temperature trimmer
CAR - Comando Amico Remoto remote control R10 - Main switch
(optional) S4 - D.h.w. flow switch
CZ - Zoned control unit (optional) S5 - System pressure switch
E1 - Ignition electrodes S6 - Flue pressure switch
E2 - Detection electrode S8 - Gas type selector
E4 - Safety thermostat S20 - Room thermostat (optional)
F1 - Line fuse T1 - Ignition transformer
F2 - Neutral fuse X40 - Room thermostat jumper
M1 - Boiler pump Y1 - Gas valve
M20 - Fan Y2 - Gas valve modulator
11
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
AMBIENT THERMOSTAT OR REMOTE CONTROL used, connect to terminals 40 and 41 and eliminate jumper
The boiler is pre-engineered for installation of the Amico Re- X40. If both are used, connect S20 to terminals 40 and 7
mote Control (CAR), which must be connected to terminals 42 and P1 to terminals 8 and 41 after having eliminated jumper
and 43 of connector X2 on the integrated electronic board, in X40.
compliance with the polarity and eliminating jumper X40. The External Probe (B4) must be connected to terminals 38
The boiler is pre-engineered for installation of the Ambient and 39 of connector X2 on the integrated electronic board.
Thermostat (S20) and Programmer Clock (P1). If only one is
Connector on the
electronic board
brown
blue
blue
brown
brown
white
white
white
black
black
black
black
black
black
grey
blue
grey
grey
grey
grey
red
red
red
red
red
230 Vac Zone Control
50Hz Unit
supply
brown
blue
y/g
brown
blue
NAT-LPG
Primary
Secondary
12
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
AMBIENT THERMOSTAT OR REMOTE CONTROL used, connect to terminals 40 and 41 and eliminate jumper
The boiler is pre-engineered for installation of the Amico Re- X40. If both are used, connect S20 to terminals 40 and 7
mote Control (CAR), which must be connected to terminals 42 and P1 to terminals 8 and 41 after having eliminated jumper
and 43 of connector X2 on the integrated electronic board, in X40.
compliance with the polarity and eliminating jumper X40. The External Probe (B4) must be connected to terminals 38
The boiler is pre-engineered for installation of the Ambient and 39 of connector X2 on the integrated electronic board.
Thermostat (S20) and Programmer Clock (P1). If only one is
Zone Control
Unit
230 Vac
50Hz
supply
brown
white
white
white
black
black
black
black
black
black
blue
grey
grey
grey
grey
red
red
red
red
red
RELAY
BOARD
yellow/green
brown
blue
brown
blue
NAT-LPG
Primary
Secondary
13
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
14
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
15
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
LEGEND:
1 - Gas valve 10 - System expansion vessel
2 - Burner 11 - Automatic vent valve
3 - Primary heat vexchanger 12 - Boiler pump
4 - Flue hood 13 - Draining valve
5 - Fan 14 - Three-way valve (without motor)
6 - Sealed chamber 15 - Adjustable by-pass
7 - Flue pressure switch 16 - System pressure switch
8 - Flow probe 17 - 3-bar safety valve
9 - Safety thermostat 18 - Filling valve
16
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
Maximum nominal heat input kW (kcal/h) 25.9 (22,241) 30.1 (25,920) 34.4 (29,579)
Maximum useful heat ouput kW (kcal/h) 24.0 (20,640) 28.0 (24,080) 32.0 (27,520)
Minimum nominal heat input kW (kcal/h) 10.7 (9,195) 12.2 (10,488) 14.6 (12,590)
Minimum useful heat output kW (kcal/h) 9.3 (8,000) 10.5 (9,030) 12.5 (10,750)
Efficiency at 100% heat output % 92.8 92.9 93.0
Efficiency at 30% heat output load % 90.7 90.9 91.5
Central heating circuit
Adjustable central heating temperature °C 35 - 85 35 - 85 35 - 85
Max system operating temperature °C 90 90 90
Max system operating pressure bar 3 3 3
Nominal (actual) capacity of expansion vessel litres 10 / (7.4) 10 / (7.4) 10 / (7.4)
Preload pressure of system expansion vessel bar 1.0 1.0 1.0
Available head with 1000 l/h flow rate kPa (m H2O) 35.30 (3.6) 38.24 (3.9) 39.22 (4.0)
Domestic hot water circuit
Useful heat output for D.H.W. production kW (kcal/h) 24.0 (20,640) 28.0 (24,080) 32.0 (27,520)
D.H.W. temperature adjustable range °C 30 - 60 30 - 60 30 - 60
Minimum D.H.W. dynamic circuit pressure bar 0.3 0.3 0.3
Maximum D.H.W. circuit pressure bar 10 10 10
Min. D.H.W. flow rate litres/min 1.5 1.5 1.5
Flow rate for continuous service (∆t 30°C) litres/min 11.5 13.4 15.3
Gas supply
NATURAL GAS (G20) MIN - MAX mbar 2.20 - 12.20 1.80 - 10.50 2.20 - 12.40
nozzles n°- ø mm 11 x 1.35 14 x 1.35 15 x 1.35
LPG (G30) MIN - MAX mbar 6.00 - 27.50 4.95 - 27.41 5.39 - 28.20
nozzles n°- ø mm 11 x 0.79 14 x 0.77 15 x 0.79
LPG (G31) MIN - MAX mbar 7.00 - 36.20 6.30 - 36.30 7.09 - 36.00
nozzles n°- ø mm 11 x 0.79 14 x 0.77 15 x 0.79
Supply voltage V/Hz 230 - 50 230 - 50 230 - 50
Nominal power absorption A 0.62 0.83 0.96
Installed electric power W 130 150 170
Power absorbed by fan W 25 48 60
Power absorbed by pump W 90 88 98
Electrical insulation degree IP X4D X4D X4D
Boiler water content litres 1.3 3.3 3.5
Empty boiler weight kg 43 45 46
17
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
EOLO 24 EOLO 28
18
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
EOLO 28
19
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
The gas flow rates refer to the NHV at 15°C and with a 1013 mbar pressure.
The fumes temperature values refer to a 15°C inlet air temperature.
20
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
The gas flow rates refer to the NHV at 15°C and with a 1013 mbar pressure.
The fumes temperature values refer to a 15°C inlet air temperature.
21
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
The gas flow rates refer to the NHV at 15°C and with a 1013 mbar pressure.
The fumes temperature values refer to a 15°C inlet air temperature.
22
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
Antifreeze electric heating element kit (-15 °C) Supplementary system expansion vessel kit (2 litres)
code 3.015348 code 3015413
Control unit kit for zoned systems code 3.011668 Universal connection kit code 3.011667
Connections set kit code 3.019319 Disconnector kit for the water main code 3.015408
The boiler can be coupled to the DIM (Multi-system Distribution Manifold) available in 5 recessing kits.
23
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
Antifreeze electric heating element kit (-15 °C) Supplementary system expansion vessel kit (2 litres)
code 3.015348 code 3015450
On-off cock kit code 3.4297 Universal connection kit code 3.011667
Disconnector kit for the water main code 3.015408 Connections set kit code 3.019319
The boiler can be coupled to the DIM (Multi-system Distribution Manifold) available in 5 recessing kits.
24
EOLO Maior kW Export
EOLO Maior kW VIP Export
EOLO Maior kW X Export
Weekly digital timer-thermostat Antifreeze electric heating element kit (-15 °C)
code 3.014438 code 3.015348
Configurable relay interface kit Control unit kit for zoned systems
code 3.015350 code 3.011668
Water Heater connection kit Supplementary system expansion vessel kit (2 litres)
code 3.015359 code 3.015413
On-off cock kit code 3.4297 Connections set kit code 3.019328
Riser pipe connection kit (WHU 105 and WHU 200) code 3.014920
The boiler can be coupled to the DIM (Multi-system Distribution Manifold) available in 5 recessing kits.
25
Immergas reserves the right to carry out, without notice, any modification to its models which it deems useful for the evolution of the
product. Code S.0093 rev. 000 - 03/2008 - Technical Documentation Office - Immergas Marketing Office
During their working life,
the performances of the
products are influenced by
external factors such as the
hardness of the domestic
water, the weather condi-
tions, scaling in the system,
etc. The data indicated in
this brochure refer to new
products, installed and
used in compliance with the
current standards in force.
N OT E : r e m e m b e r t o
have your applian-
ce periodically serviced.