0% found this document useful (0 votes)
144 views19 pages

Aconis2000e Introduction PDF

The document describes an integrated machinery control and monitoring system. It provides details on the system overview, configuration, hardware, software, characteristics, and global service network. The system allows flexibility in architecture from low to high complexity and integration. It focuses on safety, ease of use, and low maintenance costs.

Uploaded by

lujohn28
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
144 views19 pages

Aconis2000e Introduction PDF

The document describes an integrated machinery control and monitoring system. It provides details on the system overview, configuration, hardware, software, characteristics, and global service network. The system allows flexibility in architecture from low to high complexity and integration. It focuses on safety, ease of use, and low maintenance costs.

Uploaded by

lujohn28
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

ACONIS-2000E

INTEGRATED MACHINERY CONTROL & MONITORING SYSTEM


Table Contents

• 1. SYSTEM OVERVIEW
• 2. SYSTEM CONFIGURATION
• 3. HARDWARE CONFIGURATION
• 4. SOFTWARE CONFIGURATION
• 5. SYSTEM CHARACTERISTIC
• 6. GLOBAL SERVICE NETWORK
1. System Overview
• ICMS (Integrated Control and Monitoring System)
– Machinery and cargo control and monitoring
• System Benefits for Shipowner
– The benefits for the shipowner are focused on
safety and reducing the cost of ownership ;
• Easy to install and extension
• Easy to learn and use
• High quality product
• Low maintenance cost
• System Benefits for Shipyard
– The benefits for the shipyard are focused on total cost reduction during
installation and commissioning ;
• Saving the cable and cabling work
• Simple to commissioning
• Easy to other system interface
2. System Configuration
• System Capacity(1)
2. System Configuration
• System Capacity (2)

• I/O CPU Module in I/O Cabinet : 32 Stations (Max.)


• I/O Card Modules :30 I/O Card Modules (Max.) per I/O CPU
- Digital Input 16 Ch., Digital Output 16 Ch., Analog Input 16 Ch., Analog Output 8 Ch.
• Extension Alarm System Panels : 15 Panel (Max.)
• Communication CPU : RS232/422/485, Independent 8 Ch.
2. System Configuration
• System Redundancy Function
• System & Network Configuration
– System : System Server, MPM
– Network : Ethernet, Fieldbus, EAS, Process I/O Bus
3. Hardware Configuration
• Server & Graphic Client System
– Embedded Industrial-PC System
• Industrial AMD Geode™ NX 1750 (1.4 GHz) Processor based
-Low Power Consumption, Long-term Manufacturing/Support
-FSB : 266MHz, Op.Temp. : 95 °C, Power Comsumption : 14W
• Industrial NX DB1750 & SIS (741CX/964) Chipset based System
• SDRAM DDR 333(for Notebook) PCI, USB 2.0 (#5), Ethernet(10/100/Gigabit),
Serial-ATA (#2), Serial (#2, RS232/422/485 based)
3. Hardware Configuration
• I/O Cabinet Configuration
– Main I/O Control Unit and Local I/O Control Unit
▪ I/O CPU Modules
▫ Redundant Field-bus Network, 5 Mbps (Max.),
ARCnet Field-bus Protocol
▫ Embedded Real-time Operating System
▫ Redundant CPU & Communication
▪ I/O CARD Modules
▫ 8 Bit Embedded RISC Processor
▫ Digital Input 16 Ch., DC 24V
▫ Digital Output 16 Ch., Dry Contact
▫ Analog Input 16 Ch., RTD/4~20mA, 0~5V, 1~5V
▫ Analog Output 8 Ch., 4~20mA, 0~5V, 1~5V
▫ Universal I/O 8 Ch. : DI, AI
3. Hardware Configuration
• Extension Alarm System
▪ Extension Alarm System Modules
▫ 4 line text LCD
▫ Redundant Field-bus Communication
▫ LCD/LED, Day and Night/Brightness Control

• Communication System ▪ Communication CPU Modules


▫ Redundant Ethernet Network
▫ RS232, RS422, RS485 Interface
▫ Communication Protocols :
- NMEA-0183, IEC61162-1, Modbus ASC/BIN
- Maker’s Communication Protocols
4. Software Configuration
• Overview
System Specification
Operating System Microsoft Windows-2000/XP
Server System Redundant Server
Integrated Monitoring Database Standard SQL Database
&
Control System Report/Log Report/Log Generator
Communication (Operator Workstation) Redundant Ethernet, 10/100 Mbps
Communication (I/O Processor Controller) Redundant ARCnet Field-bus, 1 ~ 5Mbps

System Functions
PI/PID Controls
Applicable
Valve Control
Controls
Pump Control
Power Management System
Cargo & Ballast Control/Monitoring System
Expansible
Ship Performance System
Systems
Reefer Container Monitoring System
Hull Stress Monitoring System
Incorporated with Integrated Bridge System
Miscellaneous Interface to VDR/AIS
Interface to various Computer systems
4. Software Configuration
• Graphic Display System (1)
– Standard Graphic Display

– Machinery Alarm & Monitoring System


4. Software Configuration
• Graphic Display System (2)
– Cargo Monitoring System

– Power Management System


5. System Characteristic
The modular concept of ACONIS-2000E allows flexibility in system
architecture, from low complexity to highly integrated systems.
• Highlights
- EASY TO INSTALL AND EXTENSION, EASY TO LEARN AND USE

- DISTRIBUTED I/O ACQUISITION AND CONTROL PROCESSING(DCS)

- NO SPECIAL MAINTENANCE SKILL REQUIRED

- REDUNDANT NETWORK(LAN) AND REDUNDANT FIELD-BUS(ARCnet) COMMUNICATION

- INDUSTRIAL STANDARD WINDOWS BASED SERVER

- EASY INTEGRATION AND EXTENSION WITH OTHER SHIPBOARD DEVICE & SYSTEMS
5. System Characteristic
• System Engineering
– Easy to Install and Extension with Client Graphic Systems
• ECR/CCR and Bridge, other Officer/Engineer/Public Rooms
– Easy to Install and Extension with I/O Processing
• Redundant/Hot Backup I/O Processing Unit (I/O CPU, Field-bus)
• Basic Input/Output Card (DI/DO/AI : 16 Ch., AO : 8 Ch.,)
- Reliable Diagnostic Function (DI/DO/AI/AO), Wire break Function (DI)
• Universal Input/Output Card 16 Ch. (DI/DO/AI/AO)
– Easy to Integrate and Extension with Other Systems
• Other Shipboard System Interface by Communication System
• RS232/RS422/RS485, NMEA/IEC61162-1/Modbus and Maker’s Protocol
5. System Characteristic
• System Installation
– Easy to Install and Extension with Module-based System(DIN)

CPU & I/O


MAIN I/O UNIT and LOCAL I/O UNIT I/O UNIT
CARD
CONFIGURATION INSTALLATION
MODULE
5. System Characteristic
• System Commissioning
– On-line System Check and Easy to confirm in Client Graphic Display
– System Status & Monitoring, Parameter Tuning ;
• I/O Channel Information, I/O Parameter Modification

System Status
Check in Notebook

Main & Local I/O Unit


Engine Control Room
5. System Characteristic
• System Maintenance
▪ For Low Maintenance Cost ;
- On-line System Check
- On-line Channel/Parameter Modification
- Live Insertion and Extraction with I/O CPU and I/O Card
- High Reliability System to EMI/EMC
6. Global Service Network
Rotterdam

1
Seattle
Head Office
San Francisco 3 Ulsan, HHI
Augustine
2
New-Orleans
4

Singapore

Service Agent HHI Service Center


ROTTERDAM
1 Tel(+1) 425-
425-745
745--4803 3067 NW Rotterdam, The Netherlands
Fax(+1) 425-
425-741
741-- 2822 Tel(+31)-10212-1567
2 Fax(+31)-10212-5134
Mobile(+1) 206-
206-412
412--8754
3 E- mail : [email protected]
SINGAPORE
4 Attn: Mr. J. H. Lee
Singapore 038987, Singapore
Tel(+65)-6-337-2366
Fax(+65)-6-337-8966

You might also like