Normal Conditions at 100% Barometer Amb Temp,°C Inlet Capacity: Ist Stage

This document summarizes the normal operating conditions and performance of an air compressor at 100% capacity. It provides details on inlet and outlet conditions such as volumetric flow, temperature, and pressure. It then estimates the horsepower required at 1,859 HP and reviews the estimated performance of a steam turbine that would provide that power output.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views1 page

Normal Conditions at 100% Barometer Amb Temp,°C Inlet Capacity: Ist Stage

This document summarizes the normal operating conditions and performance of an air compressor at 100% capacity. It provides details on inlet and outlet conditions such as volumetric flow, temperature, and pressure. It then estimates the horsepower required at 1,859 HP and reviews the estimated performance of a steam turbine that would provide that power output.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

AIR COMPRESSOR 12/03/2018

NORMAL CONDITIONS AT 100%

BAROMETER 13.6 PSIA


Amb Temp,°C 25

INLET CAPACITY: Ist Stage

Volumetric Flow, cfm 8,937


Mass Flow, lb/min. 617

TEMPERATURE:

Inlet, °F 80.0

PRESSURE:

Inlet Pressure, psia 13.6


Outlet Pressure, psia 115.0

GAS INLET CONDITIONS:

Molecular Weight 29.000


Specific Heat Ratio, k1=Cp/C 1.1980
Compressibility, Z1 0.9865

GAS OUTLET CONDITIONS:

Specific Heat Ratio, k2=Cp/C 1.1906


Compressibility, Z2 0.9737

ESTIMATED HORSE POWER 1,822

TOTAL ESTIMATED HP = 1,822


Gear and Other Losses 2.00% 36
Total Req'd HP = 1,859

ESTIMATED STM TURBINE PERFORMANCE

Assumed Turbine Efficiency = 77.00%


Stm Press to Turbine, psig = 600
Stm Temp to Turbine, °F = 690
Extraction pressure, psig 60
Condensing Press. psia 1.965

Stm Turb HP lb/hr


-------------- ---------------
Extraction stm = 1,899 32,000
Condensing stm = 0 0
Total Steam and HP = 1,899 32,000 100.00%