General Regulations Part 3, Chapter 1: Table 1.8.5 Structural Misalignment and Fit (Steel and Aluminium)
General Regulations Part 3, Chapter 1: Table 1.8.5 Structural Misalignment and Fit (Steel and Aluminium)
4390/139
l2 4390/140
4390/141
l2
4390/142
4390/143
4390/145
90 Lloyd's Register
Rules and Regulations for the Classification of Special Service Craft, July 2016
General Regulations Part 3, Chapter 1
Section 8
> 80 1/75
where
s = stiffener spacing, in mm
t = plating thickness, in mm
δp = panel deflection, in mm
dp
4390/194
s
Lloyd's Register 91
Rules and Regulations for the Classification of Special Service Craft, July 2016
Section
1 General
2 Deflection control
3 Stress control
4 Buckling control
5 Vibration control
n Section 1
General
1.1 Application
1.1.1 The requirements of this Chapter are applicable to mono-hull and multi-hull craft of aluminium construction as defined in
Ch 1, 1 Background.
1.2 General
1.2.1 The failure modes criteria contained within this Chapter are to be used in the formulae from the preceding Chapters to
determine the scantling requirements. In addition, they are to be used when direct calculation methods are proposed as an
alternative.
1.3.1 The symbols and definitions applicable to this Chapter are defined in the appropriate Sections.
1.3.2 The slamming zone area referred to in this Chapter is defined as the region where the operational non-displacement
mode pressures exceed the operational displacement mode pressures.
1.4.1 Where direct calculations are proposed, the requirements of Pt 3, Ch 1, 2 Direct calculations are to be complied with.
1.4.2 In addition, with the agreement of Lloyd's Register (hereinafter referred to as 'LR'), tests may be conducted to
demonstrate the actual response of the structure and the results verified against the failure mode criteria in this Chapter.
n Section 2
Deflection control
2.1 General
2.1.1 The limiting deflection requirements for plate panels and stiffening members are given in terms of limiting deflection
coefficient, f δ, see Table 7.2.1 Limiting deflection ratio. The coefficient equates to a span/deflection ratio in consistent units.
Bottom structure:
Side structure:
Superstructures/deckhouses stiffeners: