0% found this document useful (0 votes)
1K views3 pages

DataSheet CoaDATA 504 EN 11-2017 PDF

Uploaded by

Habib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views3 pages

DataSheet CoaDATA 504 EN 11-2017 PDF

Uploaded by

Habib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1 / 4

September 2017

CoaDATA 504
Semi-automated 1-channel coagulation
analyzer for fast and accurate
determination of coagulation assays.
Compact in size, easy to operate, this
analyzer is the ideal partner for the small
laboratory, medical practices and
intensive care.

The CoaDATA 504 uses the


turbodensitometric measuring principle
and combines the advantages of
mechanical and optical detection methods.
This standardized measurement method
ensures reliable measurements even when
using turbid samples and reagents.

labitec.com

LABiTec® - LAbor BioMedical Technologies GmbH · An der Strusbek 6 · 22926 Ahrensburg · Germany
Phone: +49 (0)4102 4795-0 · Fax: +49 (0)4102 4795-35 · Mail: [email protected]
2 / 3

CoaDATA 504

FEATURES DETECTION PRINCIPLE FEATURES


• Turbodensitometric (opto-mechanic) • Open System, free editable reagent
• Magnetic stir bar for homogenizing parameter
the test approach and increase of • 15 programmable test positions
sensitivity • Automated calculation of seconds,
• Large measuring range with higher INR, %, g/l, mg/dl, Ratio
accuracy and precision compared to • Editable calibration-/reference curve
only optical detecting principles (9 points)
• Ambient light compensation • Patient-ID, numeric (manually) and
• Plasma Samples alphanumeric (Barcode)
• Micro volume: 150µl test volume • Uni-directional HOST communication
• Multi-language user interface
MEASURING UNIT (37,4° C CONTROLLED) (DE, EN, ES, FR, PT, RU)

• 1 Measuring channel
• 1 Reagent position
• 4 Cuvette incubation positions

labitec.com

LABiTec® - LAbor BioMedical Technologies GmbH · An der Strusbek 6 · 22926 Ahrensburg · Germany
Phone: +49 (0)4102 4795-0 · Fax: +49 (0)4102 4795-35 · Mail: [email protected]
3 / 3

CoaDATA 504

ASSAYS COAGULATION REAGENTS THROMBOSIS RISK REAGENTS


• PT (Seconds, %, INR) • Protein C (Clotting Test)
• aPTT (Seconds, RATIO) • Protein S (Clotting Test)
• Fibrinogen according to Clauss
(mg/dl, g/l)
• Thrombin Time (Seconds)
• Batroxobin Time (Seconds)

FACTOR DEFICIENT REAGENTS


• Extrinsic Factors II, V, VII
and X (PT based)
• Intrinsic Factors VIII, IX, XI
and XII (aPTT based)

TECHNICAL DATA DIMENSIONS: OPTIONS:


21 x 15,5 x 8 cm (LxWxH) External thermal printing device

POWER SUPPLY: INTERFACES:


100V-240V, 47-63Hz, 260mA • ChipCARD® reading unit
• RS232 (Printer / Barcode Scanner)
OUTPUT: • USB-Device (HOST)
12VDC / 1.25A • SD-Card

WEIGHT:
0,7 kg

labitec.com

LABiTec® - LAbor BioMedical Technologies GmbH · An der Strusbek 6 · 22926 Ahrensburg · Germany
Phone: +49 (0)4102 4795-0 · Fax: +49 (0)4102 4795-35 · Mail: [email protected]

You might also like