Design of Column
Design of Column
Design constants:
fy = 415N/mm2
fck =25N/mm2
Load combination:[1.2×DL+1.2LL+1.2EQX]
Design Data:
pu = 2069.135KN
Mux =11.983KNm
Muz = 156.357KNm
58
Then,
2746
Lex/D = =6.102 <12
450
2746
Lex/b = = 6.102 <12
450
P =3%
𝑝 3
= = 0.12
𝑓𝑐𝑘 25
OK.
59
Moment due to eccentricity
=42.39 KNm
Mux =42.39KNm
Muz = 156.35KNm
Als
From SP-16,
Mux1/fck×b×D2 = 0.13
Similarly,
60
As per clause 39.6,IS 456-2000
Puz = 0.45×fck×Ac+0.75×fy×Asc
But , Ag = Ac+Asc
3
450×450 = Ac+ × 450 × 450
100
Ac =196425mm2
Asc =6075mm2
Then,
Pu/Puz αn
≤ 0.2 1
≥ 0.8 2
By interpolation,
αn = 1.508
The resistance of a member subjected to axial force and biaxial bending moment
shall be obtained on the basis of assumption given in 39.1 and 39.2 with the neutral
axis so chosen to satisfy the equilibrium of load moments above two axes.
Alternatively such members may be design by the following equation:
61
[Mux/Mux1]αn+[Muz/Muz1]αn≤ 1.0
Load combination Pu Mux Muz Col. P p/fck pu/fck Mu/fck Mux αn C<
Size ( ×b×D ×b×D =Muz Pu /P 1
2
% uz
)
1.5DL+1.5LL 1842.03 7.725 3.19 450 3 0.12 0.36 0.135 307. 0.4 1.4 0.1
54 4 <
Ok
1.2DL+1.2LL+1.2EQX 2069.14 8.535 336.96 450 3 0.12 0.4 0.125 284. 0.5 1.1 0.9
765 5 5<
Ok
1.2DL+1.2LL+1.2EQX 1465.22 263.761 2.519 450 3 0.12 0.289 0.135 307. 0.35 1.2 0.8
54 5 7<
Ok
1.2DL+1.2LL-1.2EQX 878.109 3.825 332.13 450 3 0.12 0.173 0.155 353. 0.71 1.0 0.9
105 1 9<
Ok
1.2DL+1.2LL-1.2EQX 1482.03 251.4 2.311 450 3 0.12 0.293 0.142 323. 0.36 1.2 0.7
493 6 <
Ok
1.5DL+1.5EQX 1935.48 9.017 423.52 450 3 0.12 0.38 0.130 296. 0.47 1.4 Ok
156 5
1.5DL+1.5EQX 1180.58 328.049 5.471 450 3 0.12 0.23 0.150 341. 0.28 1.1 Ok
718 3
1.5DL-1.5EQX 446.692 3.13 412.83 450 3 0.12 0.08 0.150 341. 0.1 0.8 Ok
5 718 3
1.5DL-1.5EQX 1201.59 315.902 5.21 450 3 0.12 0.237 0.150 341. 0.25 1.1 0.9
718 5 6<
Ok
0.9DL+1.5EQX 1459.04 6.588 421.38 450 3 0.12 0.288 0.145 330. 0.35 1.2 Ok
328 5
0.9DL+1.5EQZ 704.s143 325.62 3.335 450 3 0.12 0.139 0.150 341. 0.17 0.9 Ok
62
718 5
0.9DL-1.5EQX 29.471 0.7 414.97 450 3 0.12 0.005 0.150 341. 0.00 0.6 Ok
1 718 7 7
0.9DL-1.5EQZ 725.15 318.332 725.15 450 3 0.12 0.15 0.155 341. 0.17 0.9 Ok
718 5
Here,from the above observations / calculations, the critical load for the column is
the load combination no.6,i.e
Use 12-25mm dia. bars giving total area equal to 63.81 cm2>60.75cm2
=16×25 = 400mm
3. ≥ 300mm
63