The JDM11-6H electronic counter can be used as a component for control circuit counting. It has a 6-digit LED display, a wide counting range, stable performance, and easy installation. It can count up to 999999 and accepts input signals from contacts, sensors, or voltage levels. It has no-power memory to retain data for 10 years without power.

Uploaded by

Scarduelli
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views2 pages

JDM11-6H en

The JDM11-6H electronic counter can be used as a component for control circuit counting. It has a 6-digit LED display, a wide counting range, stable performance, and easy installation. It can count up to 999999 and accepts input signals from contacts, sensors, or voltage levels. It has no-power memory to retain data for 10 years without power.

Uploaded by

Scarduelli
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

JDM11-6H electronic counter manual

JDMU-6H electronic counter can be used as a control circuit's count component, Its rated voltage is less than
or equal to 220VAC or 36VDC, with a 6 digit 0.36 inch LED digital tube display. Adopt high-performance count
chip, with an advantage of wide count range, stable and reliable performance, easy installation, etc.
Compliance: GB14048.5, JB/T8794-2010.
▇ Model number legend
JDM 11 - 6H - □ □ - □
Electronic Design Counter digit: Input signal Supply voltage Input voltage (Just voltage input have)
counter code 6H-6 digital display C: Contact 220V: 220VAC 220V: 220VAC
SN: Sensor (NPN) 110V: 110VAC 110V: 110VAC
SP: Sensor (PNP) 24V: 24VAC/DC 24V: 24VAC/DC
V: Voltage (level) 12V: 12VAC/DC 12V: 12VAC/DC

▇ Main technical pamameters


1. Supply voltage: according to case label
2. Power consumption: 3VA max
3. Counting range: 1-999999

om
4. Counting speed: 10 cps (count pulse width≤50ms)
5. Input signal: contact, level, NPN sensor, PNP sensor, can be selected
6. Counting error: ≤1
7. Reset time: ≥0.5s
8. Power reset: ≥1s
9. Reset mode: press the panel pushbutton .c
ai
10. Not have output control
11. No-power memory: 10 years min
l
12. Net weight: about 70g
ng

13. Perforation dimensions: 51x26mm max


14. Mounting type: Panel
15. Operating temperature: -5 to 45 ℃
.fi

▇ External dimensions (Unit: mm)


w

3
JDM11-6H
COUNTS
w

40.5 26
w

RESET

92
56.5
▇ Perforation dimensions (Unit: mm)
2-Φ3.5

26 31

18
▇ Wiring diagram

1 2 3 4 1 2 3 4 1 2 3 4 5

BU BK BN
Contact Power Voltage level Power Sensor Power

Contact input Level input Sensor input

▇ Use description
1. the counter has No-power memory function: when the counter is working, the power is off, the data can be
remained for 10 years; When the power is on next time, the counting will be continued.
2. Panel reset: If you need the counter is counted from 0, can press the panel reset pushbutton, it will be reset.
3. The count pulse width is greater than or equal to 50ms.
4. When the input signal is passive contact, the count speed is low.
5. When the input signal is voltage: connect ① to negative, ② to positive. The input voltage should be
4-30VDC.

om
6. When the input signal is sensor: the sensor should be DC6-36V
7. The count signal input line should be as short as possible, and avoid to put it together with other lines (such
as power lines) in one tube or twisting, use the double shielded cable if necessary.