General Purpose Aluminium Motors: Technical Data For Totally Enclosed Squirrel Cage Three Phase Motors
General Purpose Aluminium Motors: Technical Data For Totally Enclosed Squirrel Cage Three Phase Motors
2
4 M3AA 112 M 1455 88.0 0.77 9 1455 89.0 0.77 8.2 0.018 34 56
5.5 M3AA 132 S 1460 89.2 0.84 11 1460 89.4 0.84 10.3 0.038 48 59
7.5 M3AA 132 M 1450 90.1 0.87 14.7 1450 90.2 0.87 13.5 0.048 59 59
11 M3AA 160 M 1460 91.1 0.84 22 1470 91.6 0.82 20.5 0.091 94 62
15 M3AA 160 L 1450 91.8 0.84 30 1460 91.9 0.82 28 0.102 103 62
18.5 M3AA 180 M 1465 91.7 0.85 36 1470 92.2 0.83 34 0.161 124 62
22 M3AA 180 L 1465 92.7 0.86 42 1475 93.3 0.84 38 0.225 161 63
30 M3AA 200 MLB 1470 93.1 0.85 58 1475 93.5 0.84 54 0.34 205 63
37 M3AA 225 SMA 1475 93.4 0.84 72 1480 93.7 0.81 68 0.37 215 66
45 M3AA 225 SMB 1475 94.0 0.85 86 1480 94.2 0.81 82 0.42 230 66
55 M3AA 250 SMA 1475 94.3 0.86 103 1480 94.7 0.84 96 0.72 275 67
75 M3AA 280 SMA 1475 94.3 0.87 139 1480 94.8 0.86 128 0.88 380 67
90 M3AA 280 SMB 1470 95.0 0.89 164 1475 95.1 0.87 153 0.95 405 67
Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz.
Rated voltage at 50 Hz and motor wound for Recalculation factor Rated voltage at 50 Hz and motor wound for Recalculation factor
220 V 1.82 500 V 0.80
230 V 1.74 660 V 0.61
415 V 0.96 690 V 0.58
ABB LV Motors / Cat. BU / General purpose motors / Aluminium GB 09-2003 /Corr. 2003-10-20 31