0% found this document useful (0 votes)
93 views1 page

General Purpose Aluminium Motors: Technical Data For Totally Enclosed Squirrel Cage Three Phase Motors

1. The document provides technical specifications for general purpose aluminum motors including output power, motor type, speed, efficiency, power factor, current, moment of inertia, weight, and sound pressure level. 2. The motors can operate at speeds of 1500 rpm and voltages of 380V or 415V 50Hz. Data is provided for various motor sizes ranging from 1.1kW to 90kW. 3. The document also includes recalculation factors for current at different rated voltages from 220V to 690V.

Uploaded by

Ardian20
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views1 page

General Purpose Aluminium Motors: Technical Data For Totally Enclosed Squirrel Cage Three Phase Motors

1. The document provides technical specifications for general purpose aluminum motors including output power, motor type, speed, efficiency, power factor, current, moment of inertia, weight, and sound pressure level. 2. The motors can operate at speeds of 1500 rpm and voltages of 380V or 415V 50Hz. Data is provided for various motor sizes ranging from 1.1kW to 90kW. 3. The document also includes recalculation factors for current at different rated voltages from 220V to 690V.

Uploaded by

Ardian20
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

General purpose aluminium motors

Technical data for totally enclosed squirrel


cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Moment of Sound
Effi- Power Current Effi- Power Current inertia pressure
Output Motor type Speed ciency factor IN Speed ciency factor IN J = ¼ GD2 Weight level LP
kW r/min % cos ϕ A r/min % cos ϕ A kgm2 kg dB(A)

1500 r/min = 4 poles 380 V 50 Hz 415 V 50 Hz Basic design


1.1 M3AA 90 L 1410 83.6 0.82 2.5 1430 84.4 0.78 2.4 0.0043 16 50
1.5 M3AA 100 LA 1430 85.4 0.84 3.2 1450 86.1 0.79 3.1 0.0069 21 54
2.2 M3AA 100 LC 1440 86.8 0.80 4.8 1460 86.9 0.74 4.8 0.009 25 54
3 M3AA 112 MA 1455 87.4 0.81 6.5 1455 87.8 0.80 6.1 0.018 34 56

2
4 M3AA 112 M 1455 88.0 0.77 9 1455 89.0 0.77 8.2 0.018 34 56
5.5 M3AA 132 S 1460 89.2 0.84 11 1460 89.4 0.84 10.3 0.038 48 59
7.5 M3AA 132 M 1450 90.1 0.87 14.7 1450 90.2 0.87 13.5 0.048 59 59
11 M3AA 160 M 1460 91.1 0.84 22 1470 91.6 0.82 20.5 0.091 94 62
15 M3AA 160 L 1450 91.8 0.84 30 1460 91.9 0.82 28 0.102 103 62
18.5 M3AA 180 M 1465 91.7 0.85 36 1470 92.2 0.83 34 0.161 124 62
22 M3AA 180 L 1465 92.7 0.86 42 1475 93.3 0.84 38 0.225 161 63
30 M3AA 200 MLB 1470 93.1 0.85 58 1475 93.5 0.84 54 0.34 205 63
37 M3AA 225 SMA 1475 93.4 0.84 72 1480 93.7 0.81 68 0.37 215 66
45 M3AA 225 SMB 1475 94.0 0.85 86 1480 94.2 0.81 82 0.42 230 66
55 M3AA 250 SMA 1475 94.3 0.86 103 1480 94.7 0.84 96 0.72 275 67
75 M3AA 280 SMA 1475 94.3 0.87 139 1480 94.8 0.86 128 0.88 380 67
90 M3AA 280 SMB 1470 95.0 0.89 164 1475 95.1 0.87 153 0.95 405 67

1500 r/min = 4 poles 380 V 50 Hz 415 V 50 Hz High-output design


1.85 1)
M3AA 90 L 1380 78.8 0.83 4.4 1400 79.5 0.76 4.35 0.0043 16 50
2.2 1)
M3AA 90 LB 1380 78.4 0.85 5.1 1400 80.8 0.80 4.9 0.0048 17 50
4 1)
M3AA 100 LC 1410 80.0 0.82 8.8 1420 82.0 0.75 8.7 0.009 25 60
5.5 1)
M3AA 112 MB 1415 84.5 0.85 11.7 1430 85.5 0.79 11.4 0.018 34 56
9.2 1)
M3AA 132 MBA 1445 88.0 0.87 18.4 1445 88.3 0.87 16.8 0.048 59 59
11 1)
M3AA 132 MB 1445 88.2 0.87 22 1455 88.9 0.83 21 0.048 59 59
18.5 1)
M3AA 160 LB 1440 89.8 0.85 37 1450 90.8 0.83 34 0.102 103 63
30 1)
M3AA 180 LB 1465 92.2 0.85 58 1470 92.7 0.82 55 0.225 161 63
37 M3AA 200 MLB 1475 93.3 0.85 71 1475 93.3 0.82 67 0.34 205 63
48 1)
M3AA 200 MLC 2)
0.38 270 63
55 M3AA 225 SMC 1475 94.5 0.84 105 1480 94.6 0.82 99 0.49 265 66
73 1)
M3AA 225 SMD 2)
0.56 290 66
75 M3AA 250 SMB 1475 94.3 0.87 139 1480 94.8 0.86 128 0.88 335 67
95 1)
M3AA 250 SMC 2)
0.95 360 67

Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz.
Rated voltage at 50 Hz and motor wound for Recalculation factor Rated voltage at 50 Hz and motor wound for Recalculation factor
220 V 1.82 500 V 0.80
230 V 1.74 660 V 0.61
415 V 0.96 690 V 0.58

ABB LV Motors / Cat. BU / General purpose motors / Aluminium GB 09-2003 /Corr. 2003-10-20 31