This document provides design calculations for a reinforced concrete beam according to BS8110, including details of the beam geometry and materials, calculations for flexure and shear capacity, and checks that reinforcement spacing requirements are satisfied though the provided shear reinforcement is insufficient. Reinforcement and material specifications are given for a rectangular concrete beam undergoing flexure and shear loading.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
186 views
BS8110 RC Beam Design
This document provides design calculations for a reinforced concrete beam according to BS8110, including details of the beam geometry and materials, calculations for flexure and shear capacity, and checks that reinforcement spacing requirements are satisfied though the provided shear reinforcement is insufficient. Reinforcement and material specifications are given for a rectangular concrete beam undergoing flexure and shear loading.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
Project Job Ref.
Section Sheet no./rev.
1 Calc. by Date Chk'd by Date App'd by Date D 7/5/2018
RC BEAM DESIGN (BS8110)
TEDDS calculation version 2.1.12
Flanged section details
Section width; b = 400 mm Section depth; h = 700 mm Maximum flange width; bf = 1000 mm Flange depth; hf = 250 mm Concrete details Concrete strength class; C40/50 Characteristic compressive cube strength; fcu = 50 N/mm2 Modulus of elasticity of concrete; Ec = 20kN/mm2 + 200 ´ fcu = 30000 N/mm2 Maximum aggregate size; hagg = 20 mm Reinforcement details Characteristic yield strength of reinforcement; fy = 500 N/mm2 Characteristic yield strength of shear reinforcement; fyv = 500 N/mm2 Nominal cover to reinforcement Nominal cover to top reinforcement; cnom_t = 35 mm Nominal cover to bottom reinforcement; cnom_b = 35 mm Nominal cover to side reinforcement; cnom_s = 35 mm
2 x 12f bars 250 700
450
2 x 13f shear legs at 300 c/c
4 x 32f bars
300 400 300
Flanged section in flexure - Positive moment
Design bending moment; M = 500 kNm Distance between points of zero moment; L0 = 6800 mm Effective flange width; beff = min(0.2 ´ l0 + b, bf) = 1000 mm Depth to tension reinforcement; d = h - cnom_b - fv - fbot / 2 = 636 mm Percentage redistribution; mr = 0 % Redistribution ratio; bb = min(1 - mr, 1) = 1.000 K = M / (beff ´ d2 ´ fcu) = 0.025 K' = 0.156 = 0.156 K' > K - No compression reinforcement is required Lever arm; z = min(d ´ (0.5 + (0.25 - K / 0.9)0.5), 0.95 ´ d) = 604 mm Depth of neutral axis; x = (d - z) / 0.45 = 71 mm Area of tension reinforcement required; As,req = M / (0.87 ´ fy ´ z) = 1902 mm2 Tension reinforcement provided; 4 ´ 32f bars Project Job Ref.
Section Sheet no./rev.
2 Calc. by Date Chk'd by Date App'd by Date D 7/5/2018
Area of tension reinforcement provided; As,prov = 3217 mm2
Minimum area of reinforcement; As,min = 0.0013 ´ b ´ h = 364 mm2 Maximum area of reinforcement; As,max = 0.04 ´ b ´ d = 10176 mm2 PASS - Area of reinforcement provided is greater than area of reinforcement required Rectangular section in shear Design shear force ; V = 600 kN Design shear stress; v = V / (b ´ d) = 2.358 N/mm2 Design concrete shear stress; vc = 0.79 ´ min(3,[100 ´ As,prov / (b ´ d)]1/3) ´ max(1, (400 /d)1/4) ´ (min(fcu, 40) / 25)1/3 / gm vc = 0.799 N/mm2 Allowable design shear stress; vmax = min(0.8 N/mm2 ´ (fcu/1 N/mm2)0.5, 5 N/mm2) = 5.000 N/mm2 PASS - Design shear stress is less than maximum allowable Value of v from Table 3.7; (vc + 0.4 N/mm2) < v < vmax Design shear resistance required; vs = max(v - vc, 0.4 N/mm2) = 1.559 N/mm2 Area of shear reinforcement required; Asv,req = vs ´ b / (0.87 ´ fyv) = 1434 mm2/m Shear reinforcement provided; 2 ´ 13f legs at 300 c/c Area of shear reinforcement provided; Asv,prov = 885 mm2/m FAIL - Area of shear reinforcement provided is less than the minimum required Maximum longitudinal spacing; svl,max = 0.75 ´ d = 477 mm PASS - Longitudinal spacing of shear reinforcement provided is less than maximum Spacing of reinforcement (cl 3.12.11) Actual distance between bars in tension; s = (b - 2 ´ (cnom_s + fv + fbot/2)) /(Nbot - 1) - fbot = 59 mm
Minimum distance between bars in tension (cl 3.12.11.1)
Minimum distance between bars in tension; smin = hagg + 5 mm = 25 mm PASS - Satisfies the minimum spacing criteria Maximum distance between bars in tension (cl 3.12.11.2) Design service stress; fs = (2 ´ fy ´ As,req) / (3 ´ As,prov ´ bb) = 197.1 N/mm2 Maximum distance between bars in tension; smax = min(47000 N/mm / fs, 300 mm) = 238 mm PASS - Satisfies the maximum spacing criteria