0% found this document useful (0 votes)
928 views3 pages

CHINT NDK Transformer

This document provides information about NDK Control Transformers, including: - They are low voltage transformers ranging from 25VA to 5000VA capacity. - They operate within temperature ranges of -5°C to +40°C and altitudes up to 2000m. - They have multiple voltage output options and are suitable for control power supply and lighting applications. - Technical specifications and dimensions are provided for each model.

Uploaded by

tqhunghn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
928 views3 pages

CHINT NDK Transformer

This document provides information about NDK Control Transformers, including: - They are low voltage transformers ranging from 25VA to 5000VA capacity. - They operate within temperature ranges of -5°C to +40°C and altitudes up to 2000m. - They have multiple voltage output options and are suitable for control power supply and lighting applications. - Technical specifications and dimensions are provided for each model.

Uploaded by

tqhunghn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Low Voltage VT & AVR & CT & PT

Transformer
2. Type designation
NDK-□

Rated output capacity (VA): 25VA~5000VA

Control

Single-phase

Corporation character

NDK Control Transformer 3. Operation conditions


1. General 3.1 Temperature: -5℃~+40℃, the average value within
1.1 Frequency: AC 50Hz/60Hz; 1 month should not exceed +30℃ and not exceed
1.2 Application: for control power supply of apparatus, +20℃ within 1 year;
partial illumination and indicator light of machine tool 3.2 Altitude: ≤2000m;
3.3 Relative humidity: ≤95%
and other mechanic equipments.
1.3 Standard: IEC/EN 61558, Q/ZT258.

4. Features
The transformer is characterized by excellent performances,
reliable operation, compact design, safe wiring, and wide
application, etc.

K-01 > >>


Low Voltage VT & AVR & CT & PT
Transformer
5. Technical data

Capacity Rated Rated Frequency


Model (VA) input voltage(V) output voltage(V) (Hz)

NDK-25 25
NDK-50 50
NDK-100 100
NDK-150 150
NDK-200 200
NDK-250 250
NDK-300 300
6, 12, 24,
NDK-400 400
230, 400 36, 110, 127, 50/60
NDK-500 500
230, 400
NDK-700 700
NDK-1000 1000
NDK-1500 1500
NDK-2000 2000
NDK-3000 3000
NDK-4000 4000
NDK-5000 5000

Note: Customized products are available.

6. Overall and mounting dimensions


NDK-25~1000
Emax

F
K

A C

Bmax Dmax

NDK-1500~5000

Dmax

K
Emax

F
10
20

A C
Bmax

> >> K-02


Low Voltage VT & AVR & CT & PT
Transformer
Mounting dimensions Mounting holes Overall dimensions
Model (A×C) (mm) (K×J) (mm) (B×D×E) (mm)

NDK-25 62.5×50 5×8 80×80×82


NDK-50 70×58 6×10 85×83×84
NDK-100 85×64 6×10 103×87×99
NDK-150 85×72 6×10 103×93×99
NDK-200 85×83 6×10 103×105×99
NDK-250 100×80 8×11 130×120×150
NDK-300 100×84 8×11 130×125×150
NDK-400 110×114 8×11 148×155×153
NDK-500 110×114 8×11 148×155×153
NDK-700 125×99 8×11 173×158×174
NDK-1000 125×123 8×11 173×186×174
NDK-1500 160×120 10×20 265×195×265
NDK-2000 160×130 10×20 265×205×275
NDK-3000 160×140 10×20 265×220×305
NDK-4000 190×180 10×20 315×260×305
NDK-5000 190×180 10×20 315×260×305

7. Wiring

7.1 NDK-100, capacity: 100VA, input 400V 230V, 7.2 NDK-100, capacity: 100VA, input 400V, output 36V;
output 36V 24V 12V 6V capacity 60VA 12V; capacity 40VA

0 230V 400V 0 400V


Primary
Primary

Iron core Iron core

Secondary
Secondary
36V 24V 12V 6V 0 36V 60VA 0 12V 40VA 0

7.3 NDK-100, capacity: 100VA, input 400V, output 36V 12V 7.4 NDK-100, capacity: 100VA, input 400V, output 36V

0 400V 0 400V
Primary Primary

Iron core Iron core

Secondary Secondary

36V 12V 0 36V 0