0% found this document useful (0 votes)
310 views

Compressor: Process Data Sheet

This document provides process data for two centrifugal compressors, K-101 and K-102. K-101 compresses hydrocarbon gas from 2 to 35 barg and has 3 stages. K-102 compresses gas from 34 to 250 barg over 2 stages for the Monetisation of Associated Gas from an offshore flare. Both compressors will operate continuously with gas turbine drivers using treated fuel gas and superheated inlet gas.

Uploaded by

Eddie Tai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
310 views

Compressor: Process Data Sheet

This document provides process data for two centrifugal compressors, K-101 and K-102. K-101 compresses hydrocarbon gas from 2 to 35 barg and has 3 stages. K-102 compresses gas from 34 to 250 barg over 2 stages for the Monetisation of Associated Gas from an offshore flare. Both compressors will operate continuously with gas turbine drivers using treated fuel gas and superheated inlet gas.

Uploaded by

Eddie Tai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Process Data Sheet Position No.

Page 1

Compressor of 2
Location TBA Project Title Document No. Issue
Company Transwater Subproject Title
Plant No. Plant ERP No. Status
Unit No. Unit
Building No. Position K-101 Flow Diagram
1 Type / Seal type Centrifugal 1

✘ In operation Identical to Position No.


2 0

Backup equi.
3 Process Data / Operating Conditions
4 Operating points Design Minimum Normal Maximum start up condition
5 Fluid / medium HC Gas HC Gas HC Gas
6 Mass flow kg/h - 4655 13960
7 Standard volume flow Nm³/h - - - -
8 Volume flow m³/h - - - -
9 MMSCFD - 5 15
10 Temperature °C - 40 40 40
Suction side
11 Pressure barg - 2 2 2
12 Molecular Weight - 18.69 18.69 18.69
13 Cp/Cv - 1.277 1.277 1.277
14 Compressibility (Z1) - 0.9889 0.9889 0.9889
15 Density kg/m³ - 0.7928 0.7928 0.7928
16 Discharge Maximum temperature °C - VTA VTA VTA
17 side Pressure (3) barg - 35 35 35
18 maximum allowed gas working temperature °C 150 150 150
19 Dew point at suction conditions °C - - -
20 Relative humidity (H2O) % - - -
21 operating mode ✘ continuous
1

intermittent
0

h/a
22 Product properties (e.g. flammable, corrosive etc.) Flammable and corrosive inlet gas due to CO2 and H2S
23 Solids / polymerization possible / liquid -
24 Notes
25 1) 3 Stages Centrifugal Compressor
26 2) Maximum interstage temperature discharge is 150 °C
27 3) Final discharge pressure is 35 Barg
28 4) Use Gas Turbine Driver ( treated fuel gas) and (superheated gas)
29 5) Interstage cooler and scrubber by others
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Engineering Dept./- Comp. Design Check Approval
Created Modified Date Name Date Name Date
MSA 2017-08-01

F 19-0101, en, SI, Edition 2008-02 1.1.19


Process Data Sheet Position No. Page 2

Compressor of 2
Location TBA Project Title Monetisation of AG from offshore flare Document No. Issue
Company Transwater Subproject Title
Plant No. Plant ERP No. Status
Unit No. Unit
Building No. Position K-102 Flow Diagram
1 Type / Seal type Centrifugal 1

✘ In operation Identical to Position No.


2 0

Backup equi.
3 Process Data / Operating Conditions
4 Operating points Design Minimum Normal Maximum start up condition
5 Fluid / medium HC Gas HC Gas HC Gas
6 Mass flow kg/h - 12230
7 Standard volume flow Nm³/h - - - -
8 Volume flow m³/h - - - -
9 MMSCFD - 3.37 13.13
10 Temperature °C - 45 45 45
Suction side
11 Pressure barg - 34 34 34
12 Molecular Weight - 18.70
13 Cp/Cv - 1.374
14 Compressibility (Z1) - 0.01273
15 Density kg/m³ - 0.793
16 Discharge Maximum temperature °C - VTA VTA VTA
17 side Pressure (3) barg - 250 250 250
18 maximum allowed gas working temperature °C 150 150 150
19 Dew point at suction conditions °C
20 Relative humidity (H2O) 5) %
21 operating mode ✘ continuous
1

intermittent
0

h/a
22 Product properties (e.g. flammable, corrosive etc.) Flammable and corrosive inlet gas due to CO2
23 Solids / polymerization possible / liquid -
24 Notes
25 1) 2 Stages Centrifugal Compressor
26 2) Maximum interstage temperature discharge is 150 °C
27 3) Final discharge pressure is 250 Barg
28 4) Use Gas Turbine Driver (treated fuel gas) and (superheated gas)
29 5) Interstage cooler and scrubber by others
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Engineering Dept./- Comp. Design Check Approval
Created Modified Date Name Date Name Date
MSA 2017-08-01

F 19-0101, en, SI, Edition 2008-02 1.1.19

You might also like