Downloaded From Manuals Search Engine
Downloaded From Manuals Search Engine
1. SAFETY INFORMATION…………………………….1
2. DESCRIPTION……………………..…………………3
3. OPERATING INSTRUCTION………………………..6
3.1 MEASURING VOLTAGE……………………….6
3.2 MEASURING CURRENT………………………6
3.3 MEASURING RESISTANCE…………………..7
3.4 MEASURING FREQUENCY……………………7
3.5 MEASURING CAPACITANCE…………………8
3.6 CONTINUITY TEST…..………………………...8
3.7 DOIDE TEST……………………………………..8
3.9 TRANSISTOR TEST…………………………….9
4. SPECIFICATIONS…………………………………….9
5. ACCESSORIES………………………………………13
6. BATTERY & FUSE REPLACEMENT………………14
1.1 PRELIMINARY
※ When using this meter, the user must observe all
normal safety rules concerning:
— Protection against the dangers of electrical current.
— Protection of the meter against misuse.
※ Full compliance with safety standards can be
guaranteed only if used with test leads supplied. If
necessary, they must be replaced with the same model or
same electronic ratings. Measuring leads must be in
good condition.
-1-
1.3 SYMBOLS
Important safety information, refer to the operating
manual.
Earth ground
1.4 MAINTENANCE
※ Before opening the meter, always disconnect test
leads from all sources of electric current.
※ For continue protection against fire, replace fuse
only with the specified voltage and current ratings: F1:
2A/250V F2: 10A/250V
※ If any faults or abnormalities are observed, the
meter can not be used any more and it has to be
-2-
2. DESCRIPTION
This meter is an autoranging professional instrument
with 3 3/4 digit LCD display, capable of performing
functions:
- DC voltage measurement
- AC voltage measurement
- DC current measurement
- AC current measurement
- Resistance measurement
- Capacitance measurement
- Frequency measurement
- Diode test
- Transistor test
- Audible continuity test
Names of components
1-4. buttons
5. Rotary switch
6. A input jack
7. mA input jack
8. V/Ω/Hz input jack
9. COM input jack
10. Transistor input jack
-3-
-4-
-5-
3. OPERATING INSTRUCTION
-7-
-8-
4. SPECIFICATIONS
Accuracy is specified for a period of one year after
calibration and at 18°C to 28°C (64°F to 82°F) with
relative humidity to 80%.
Accuracy specifications are given as:
± % of reading ± number of least significant digits.
4.1 GENERAL
MAXIMUM VOLTAGE BETWEEN TERMINALS AND
EARTH GROUND: 1000V DC or 700 rms AC (sine)
FUSE PROTECTION: µA, mA: F 500mA/250V
A: F 10A/250V
-9-
4.2 AC VOLTAGE
Range Resolution Accuracy
400mV 0.1mV --
4V 1mV
± 0.5 % of rdg ± 0.2% of full
40V 10mV
scale ± 2 digit
400V 100mV
750V 1V ± 0.8 % of rdg ± 2 digits
Input Impedance: 10MΩ.
Frequency Range: 40Hz to 400Hz
Response: Average, calibrated in rms of sine wave
4.3 DC VOLTAGE
- 10 -
4.4 DC CURRENT
Range Resolution Accuracy
400µA 0.1µA ± 0.8 % of rdg ± 2 digits
4mA 1µA ± 0.8 % of rdg ± 2 digits
40mA 10µA ± 0.8 % of rdg ± 2 digits
400mA 0.1mA ± 1.2% of rdg ± 2 digits
10A 10mA ± 2.0 % of rdg ± 5 digits
Overload protection: F 500mA fuse for µA and mA
ranges, F 10 A fuse for A range.
4.5 AC CURRENT
Range Resolution Accuracy
± (0.8~8.0)% of rdg
400µA 0.1µA
± 3 digits
4mA 1µA ± 0.8% of rdg ± 3 digits
40mA 10µA ± 0.8% of rdg ± 3 digits
400mA 0.1mA ± 1.2% of rdg ± 3 digits
10A 10mA ± 2.0 % of rdg ± 5 digits
- 11 -
4.6 RESISTANCE
Range Resolution Accuracy
400Ω 0. 1Ω ± 0.8% of rdg ± 3 digits
4KΩ 1Ω ± 0.8% of rdg ± 1 digits
40KΩ 10Ω ± 0.8% of rdg ± 1 digits
400KΩ 100Ω ± 0.8% of rdg ± 1 digits
2MΩ 1KΩ ± 0.8% of rdg ± 1 digits
40MΩ 10KΩ ± 1.2% of rdg ± 2 digits
Max. open circuit voltage: 3.2V
4.7 CAPACITANCE
Range Resolution Accuracy
4nF 1pF
40nF 10pF
400nF 100pF
± 3.0% ± 20
4µF 1nF
40µF 10nF
200µF 100nF
4.8 FREQUENCY
Range Resolution Accuracy
100kHz 1Hz ±2%±5
- 12 -
4.11 TRANSISTOR
Function Range Base current Vce
hFE 1 to 1000 25µA 3.0V
5. ACCESSORIES
- 13 -
- 14 -
WARNING
Before attempting to open the case, be sure that test
leads have been disconnected from measurement
circuits to avoid electric shock hazard.
For protection against fire, replace fuse only with
specified ratings:
F1: 200mA/250V (quick acting)
F2: F20A/250V
- 15 -