Throttle Bushing
Throttle Bushing
Orifice
and
Throttle Bushing
Orifices
Mechanical seal recirculation through an orifice helps deter solids buildup and provides cooling to minimize flashing of
product in the seal chamber. Orifices are sized to provide adequate flush flow under specific operating conditions relative to
the seal size and fluid properties.
Standard Sizes
Part NPT Conn. Inch Millimeter Part NPT Conn. Inch Millimeter
Number Male Female D H D H Number Male Female D H D H
4R2829 .500 .500 1.188 none* 30 none* 667929 .250 .250 0.750 0.125 19 3.2
4R2106 .500 .500 1.188 0.040 30 1.0 662312 .500 .500 1.188 0.125 30 3.2
663660 .500 .500 1.188 0.056 30 1.4 4R0698 1.000 1.000 1.500 0.125 38 3.2
664836 .500 .500 1.188 0.063 30 1.6 667222 .500 .500 1.188 0.129 30 3.3
664887 .500 .500 1.188 0.073 30 1.9 665334 .500 .500 1.188 0.156 30 4.0
614620 .250 .375 0.875 0.086 22 2.2 4R1467 .500 .500 1.188 0.172 30 4.4
620822 .375 .375 1.000 0.086 25 2.2 667547 .500 .500 1.188 0.188 30 4.8
621584 .500 .500 1.188 0.086 30 2.2 4R0688 1.000 1.000 1.500 0.188 38 4.8
614619 .250 .375 0.875 0.098 22 2.5 4R1899 .500 .500 1.188 0.209 30 5.3
620821 .375 .375 1.000 0.098 25 2.5 665333 .500 .500 1.188 0.250 30 6.4
622330 .500 .500 1.188 0.098 30 2.5 671464 .375 .375 1.438 0.250 37 6.4
662813 .375 .375 1.438 0.098 37 2.5 4R0689 1.000 1.000 1.500 0.250 38 6.4
614618 .250 .375 0.875 0.113 22 2.9 4R0690 1.000 1.000 1.500 0.375 38 9.5
620820 .375 .375 1.000 0.113 25 2.9 4R0691 1.000 1.000 1.500 0.438 38 11.1
621577 .500 .500 1.188 0.113 30 2.9 4R0692 1.000 1.000 1.500 0.500 38 12.7
669706 .750 .750 1.438 0.113 37 2.9 4R0693 1.000 1.000 1.500 0.625 38 15.9
*drilled as needed
Throttle Bushings
Installed in the bottom of seal chambers, throttle bushings are used to control flow past mechanical seal faces and to lower or raise
the seal chamber pressure. Depending on the desired flow rates and equipment type, fixed or floating throttle bushings are available
for any radial clearance over the shaft. Unitized and split designs simplify installation and removal.
Note: For sizes and conditions not listed, contact your local Flowserve Representative.
The information and specifications presented in this product brochure are believed to be accurate, but are supplied for information purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a
warranty or guarantee, express or implied, with respect to the product. Although Flowserve Corporation can provide general application guidelines, it cannot provide specific information for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper
selection, installation, operation and maintenance of Flowserve products. Because Flowserve Corporation is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice.
Primary Worldwide Flow Solutions Division Locations Licensees, authorized agents, and affiliated companies located worldwide.
United States Canada Netherlands Argentina Australia
Kalamazoo, MI Edmonton, Alberta Scarborough, Ontario Roosendaal Villa Martelli Marayong NSW
Phone 616-381-2650 Phone 780-463-7958 Phone 416-292-2877 Phone 31-165-581400 Phone 54-11-4790-6800 Phone 61-2-8822-7100
Fax 616-381-8368 Fax 780-450-1241 Fax 416-292-5190 Fax 31-165-552622 Fax 54-11-4709-7072 Fax 61-2-9679-7511