Questions On DC Generator
Questions On DC Generator
sanfoundry.com
DC Machines Assessment
Questions - Sanfoundry
by Manish
6-8 minutes
Answer: d
Explanation: The relationship between various parameters
has to be presented graphically because of the magnetic
saturation effect. Four characteristics of importance are the
following: 1) No load characteristics 2) Load characteristics
3) External characteristics 4) Armature characteristics.
1 of 7 3/19/18, 7:22 AM
DC Machines Assessment Questions - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
a) Magnetization characteristics
b) Non-magnetization characteristics
c) Anti-magnetization characteristics
d) Cannot be determined
View Answer
Answer: a
Explanation: With Ia = 0 (no load) at constant n, it is the
presentation of Vt (=Ea) vs If. This is the most important
characteristic as it reveals the nature of the magnetization
of the machine. It is easy to determine as the generator is
on no load and so only low rated prime mover will serve the
purpose. It is commonly called the open–
circuit/magnetization characteristic.
Answer: b
Explanation: Open circuit characteristics is also called as
no-load characteristics or magnetization characteristics. No
load clearly states that armature current will equal to 0.
Thus, OCC is drawn at Ea vs If, Ia=0.
2 of 7 3/19/18, 7:22 AM
DC Machines Assessment Questions - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
a) Load characteristics
b) No-load characteristics
c) External characteristics
d) Armature characteristics
View Answer
Answer: a
Explanation: Since we have Ia value which is equal to rated
i.e. non-zero, it is indeed not a no-load characteristic. Axes
given are Vt and If, hence it is not an armature
characteristic. Thus, it’s called as load characteristic or
magnetization characteristic on load.
Answer: b
Explanation: As the machine would have been previously
subjected to magnetization, a small residual voltage would
be present with field unexcited. As will be seen practically,
this is necessary for generator to self-excite. So, graph will
start from just above the origin on Voc axis.
3 of 7 3/19/18, 7:22 AM
DC Machines Assessment Questions - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
Answer: b
Explanation: In conducting the OCC test, If must be raised
gradually only in the forward direction otherwise the curve
would exhibit local hysteresis loops. In OCC at If =0 there
exists small residual voltage shown by non-zero Voc.
Answer: b
Explanation: The extension of the liner portion of the
magnetization curve, is known as the air-gap line as it
represents mainly the magnetic behaviour of the machine’s
air-gap, the iron being unsaturated in this region consumes
negligible ampere-turns; in any case the effect of iron is
also linear here.
Answer: c
Explanation: For a less speed than the rated one, residual
voltage appearing at terminal call Voc will also be less than
4 of 7 3/19/18, 7:22 AM
DC Machines Assessment Questions - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
Answer: a
Explanation: Under load conditions Ea cannot be
determined from the OCC for If in the saturation region
because of the demagnetizing effect of armature reaction.
We must therefore determine experimentally the equivalent
demagnetizing ampere-turns ATd due to armature reaction
under actual load conditions.
Answer: c
Explanation: Since on load operation of a DC machine, we’ll
get terminal voltage less than the terminal voltage obtained
in OCC, graph will start from below OCC. On load, the
effect of armature reaction will draw load characteristics
parallel to the OCC below it, causing no intersection.
5 of 7 3/19/18, 7:22 AM
DC Machines Assessment Questions - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
Answer: c
Explanation: Load characteristics with at Ra =0 will lie
below the load characteristics drawn at Ra not equal to 0.
To the load characteristic we add IaRa drop to get Ea
induced emf with load. Thus, it will lie above.
Answer: c
Explanation: As a speed on which OCC is taken decreases,
the residual voltage appearing on Voc axis also decrease
and OCC starts from below, compare to first one. Thus, N1
is less comparatively, as its OCC lies below than the OCC
drawn at other speed.
6 of 7 3/19/18, 7:22 AM
DC Machines Assessment Questions - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
magnetization characteristics?
a) Ea α If
b) Ea α φ
c) If α φ
d) Cannot be determined
View Answer
Answer: b
Explanation: As the generated voltage in the armature in
the case of DC generator is proportional to terminal voltage,
which also proportional to magnetic flux, as seen by
residual voltage appearing at 0 field current. No-load and
load characteristics are called as magnetization curves.
7 of 7 3/19/18, 7:22 AM
DC Machines Problems - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
sanfoundry.com
DC Machines Problems -
Sanfoundry
by Manish
4-5 minutes
Answer: b
Explanation: It is the presentation of Ia vs If with Vt held
constant (at rated value) and generator run at constant n
and load varied. It reveals the armature reaction effect on
the flux/pole. It is also called regulation characteristic.
1 of 5 3/19/18, 7:22 AM
DC Machines Problems - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
d) Load
View Answer
Answer: c
Explanation: External characteristic is a load characteristic.
In this, variation of terminal voltage across armature current
is drawn keeping speed and field current constant. Load is
generally kept variable.
Answer: a
Explanation: Armature characteristic is drawn across Ia vs
If. This characteristic is on load characteristic, drawn when
terminal voltage and speed of the generator is kept
constant. Armature characteristic is regulation
characteristic.
Answer: c
2 of 5 3/19/18, 7:22 AM
DC Machines Problems - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
Answer: b
Explanation: It is seen from the characteristic that at low
values of Ia, the increase in If is very small to provide for
increasing Ia *Ra drop. At large values of Ia there is a sharp
increase in If to compensate for voltage drop caused by
armature reaction.
Answer: c
Explanation: The difference in the observed value and rated
value of voltage can be obtained from the y-axis that is,
from Voc. This difference is equal to Vd + Ia *Ra. Thus, by
3 of 5 3/19/18, 7:22 AM
DC Machines Problems - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
Answer: b
Explanation: According to proportionality constant obtained
by analysis of OCC, various value of armature current can
be obtained. From ΔIf values we can compute number of
turns in series of armature in cumulative compound
machine.
Answer: b
Explanation: The load characteristic of a dc generator at a
particular speed is the relationship between its terminal
voltage and load current (line current) and is also termed as
the external characteristic. The internal characteristic is the
plot between the generated emf and load current.
4 of 5 3/19/18, 7:22 AM
DC Machines Problems - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
____________
a) Parabola opening in +x direction
b) Parabola opening in -x direction
c) Parabola opening in +y direction
d) Parabola opening in -y direction
View Answer
Answer: b
Explanation: All parabolas for separately excited DC
generator, shunt generator, compound generator are
parabolas which are opening in -x directions, only centres of
all parabolas lie at different places depending on the type of
generator.
5 of 5 3/19/18, 7:22 AM
Self Excited Generator Characteristics Question... about:reader?url=https://www.sanfoundry.com/...
sanfoundry.com
Answer: b
Explanation: Rather than arranging a separate dc source
for excitation purposes, practical generators are always
excited from their own armature terminals, this method of
excitation being known as self-excitation. A self-excited
generator with such connection known as a shunt
generator.
1 of 7 3/19/18, 7:22 AM
Self Excited Generator Characteristics Question... about:reader?url=https://www.sanfoundry.com/...
_____________
a) IL – If
b) IL + IL
c) – IL – IL
d) – IL + IL
View Answer
Answer: b
Explanation: For a self-excited DC shunt generator field
winding is connected in parallel with armature winding so
that, armature current splits into load current and field
current. Load current will be given out as the machine is
working as a generator.
Answer: b
Explanation: Field is connected such that this current
increases the field mmf and therefore the induced emf, the
machine will continuously build up. For the field circuit V = If
*Rf, which is a straight-line relationship, called the Rf -line,
in V-If plot.
2 of 7 3/19/18, 7:22 AM
Self Excited Generator Characteristics Question... about:reader?url=https://www.sanfoundry.com/...
Answer: c
Explanation: When OCC is plotted against terminal voltage
and field current where, field resistance line is also drawn,
an intersection point will arise when OCC almost becomes
constant due to saturation effect. So, corresponding value
field current and no-load voltage can be observed from x
and y axis resp.
Answer: b
Explanation: When field resistance is decreased, it will
increase field current by Ohm’s law. Thus, field resistance
line will lie below the older line of field resistance.
Eventually, it’ll intersect OCC afterwards causing increase
in no-load voltage.
3 of 7 3/19/18, 7:22 AM
Self Excited Generator Characteristics Question... about:reader?url=https://www.sanfoundry.com/...
Answer: c
Explanation: We get no-load voltage when magnetization
curve intersects with field resistance line. If that intersection
is not occurring, we’ll not get no load voltage. Thus, when
both lines coincide we get undefined value of no-load
voltage.
Answer: b
Explanation: The no-load voltage is undefined for a field
resistance whose line coincides with the linear portion of the
magnetization curve. With field resistance even slightly
more than this value, the machine does not excite to any
appreciable value.
4 of 7 3/19/18, 7:22 AM
Self Excited Generator Characteristics Question... about:reader?url=https://www.sanfoundry.com/...
Answer: c
Explanation: When field resistance value increases the line
of field resistance shifts towards more +ve slope, proving
that field current decreases. This line will now intersect
OCC at lower regions indicating lower values of terminal
voltage.
Answer: a
Explanation: For Field resistance kept constant, field
resistance line will intersect OCC at different points as
speed variation may shift OCC up or down. When speed is
increased OCC shifts up indicating that no-load voltage will
also rise up.
5 of 7 3/19/18, 7:22 AM
Self Excited Generator Characteristics Question... about:reader?url=https://www.sanfoundry.com/...
View Answer
Answer: b
Explanation: The field connection to the armature is such
that the induced emf due to the residual magnetism tends
to destroy the residual magnetism, is called negative
feedback. In the absence of residual magnetism machine
will fail to self-excite.
Answer: d
Explanation: In case a and b, machine will tend to destroy
the residual magnetism present in a core, which will not
excite machine. When field resistance value is more than
critical value as seen from OCC, machine will not excite to
appropriate value.
Answer: a
Explanation: By changing the polarity of field connections to
6 of 7 3/19/18, 7:22 AM
Self Excited Generator Characteristics Question... about:reader?url=https://www.sanfoundry.com/...
Answer: d
Explanation: Negative feedback can be remedied simply by
reversing the field connection to the armature or reversing
the direction of rotation. For large dc generators with
permanent connections and a fixed direction of rotation, the
problem is overcome by temporarily exciting the field from a
battery source.
7 of 7 3/19/18, 7:22 AM
DC Machines Test - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
sanfoundry.com
Answer: b
Explanation: The operation considered here assumes that
the armature is driven at constant speed (by means of
prime mover) and the field excitation (If) is adjusted to give
rated voltage at no-load and is then held constant at this
value throughout the operation considered.
1 of 7 3/19/18, 7:22 AM
DC Machines Test - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
c) Internal factors
d) Armature reaction
View Answer
Answer: d
Explanation: In spite of fixed excitation, Ea drops off with
load owing to the demagnetizing effect of the armature
reaction. As the voltage drop is caused by magnetic
saturation effect, it increases with load non-linearity.
Answer: a
Explanation: Internal characteristic is drawn across
armature generated voltage, it doesn’t account the
presence of armature resistance. External characteristic
takes into account the presence of armature resistance as it
is drawn across terminal voltage.
2 of 7 3/19/18, 7:22 AM
DC Machines Test - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
d) Can’t say
View Answer
Answer: a
Explanation: The terminal voltage drops off much more
rapidly with load in a shunt generator than in a separately-
excited generator because of fall in field current with
terminal voltage. The external characteristic is a double-
valued curve with a certain IL (max).
Answer: d
Explanation: All the graphs when drawn across voltage and
load current, start from the same point but with increase in
values of load current all machines show different elevation
according to the values of series field resisitor.
Answer: c
3 of 7 3/19/18, 7:22 AM
DC Machines Test - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
Answer: b
Explanation: When fixed resistance is added in parallel with
series field resistance we get only one other compounding
level. So, by adding variable resistance in parallel with
series field we can get various other compounding levels.
Answer: d
4 of 7 3/19/18, 7:22 AM
DC Machines Test - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
Answer: a
Explanation: In series DC generator series resistor RSE is
added with armature circuit, thus total drop in terminal
voltage from generated armature voltage is equal to Ia *(Ra
+ RSE). While drawing internal characteristics presence of
armature resistance and series resistance is not taken into
account.
Answer: b
Explanation: For all other DC generators other than series
5 of 7 3/19/18, 7:22 AM
DC Machines Test - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
Answer: c
Explanation: Summation of armature resistance, series field
resistance, load resistance must be less than the critical
resistance. As seen in self-excited DC generator
characteristics if this value is greater than critical resistance,
voltage build-up will not be possible.
Answer: b
Explanation: Here, DC series motor fails to excite as
6 of 7 3/19/18, 7:22 AM
DC Machines Test - Sanfoundry about:reader?url=https://www.sanfoundry.com/...
7 of 7 3/19/18, 7:22 AM
Graphical Representation of External Characteri... about:reader?url=https://www.sanfoundry.com/...
sanfoundry.com
Graphical Representation of
External Characteristics
Questions and Answers
by Manish
4-5 minutes
Answer: a
Explanation: Intersection of OCC with field resistance line
gives the no-load point. All the value so obtained from x and
y axis respectively gives the terminal voltage and field
current of a DC generator at no-load.
1 of 5 3/19/18, 7:22 AM
Graphical Representation of External Characteri... about:reader?url=https://www.sanfoundry.com/...
c) 3rd quadrant
d) 4th quadrant
View Answer
Answer: a
Explanation: Rf line is a straight line passing through the
origin and having constant slope, so rising always in a
positive direction. OCC starts from some positive value on
Y axis and increases till maximum point, afterwards it starts
becoming constant, where generally it intersects with Rf
line.
Answer: c
Explanation: For representing the voltage drop in armature
resistance, we add product IaRa vertically with Rf line at
minimum 2 points and draw line parallel to Rf to get line
with V + IaRa = constant.
2 of 5 3/19/18, 7:22 AM
Graphical Representation of External Characteri... about:reader?url=https://www.sanfoundry.com/...
Answer: c
Explanation: OCC when starts from some residual voltage
on y axis, goes on increasing till some maximum value and
then starts reducing slightly. The bulk is formed where
maximum distance between OCC and v+ IaRa line is taken,
to get effective frop in armature.
Answer: d
Explanation: The demagnetization caused by armature
reaction can be quantified by equivalent field current Ifd
which can be taken as proportional to the armature current
Ia. So, by shifting the origin towards -ve x axis by Ifd we can
show armature reaction graphically.
Answer: c
Explanation: When external characteristics are plotted on
3 of 5 3/19/18, 7:22 AM
Graphical Representation of External Characteri... about:reader?url=https://www.sanfoundry.com/...
Answer: c
Explanation: Speed is directly proportional to the back emf
of a machine. So, Ea = 225 V at 1000 rpm
Ea (950 rpm) = 225 x 950 / 1000, this will give speed of
given DC machine at 950 rpm. Upon calculations we get,
Ea = 213.7 V= 214 V approx.
4 of 5 3/19/18, 7:22 AM
Graphical Representation of External Characteri... about:reader?url=https://www.sanfoundry.com/...
View Answer
Answer: a
Explanation: From the excitation balance equation, If +
[Nse/Nf] Ia – Ifd =If (net).
5 + 505(Nse /1000) – 0.95 = If (net).
Calculating for Nse by substituting If (net), we get Nse = 6.8
that is 7 turns.
5 of 5 3/19/18, 7:22 AM
DC Generator Parallel Operation Questions and... about:reader?url=https://www.sanfoundry.com/...
sanfoundry.com
Answer: c
Explanation: For connecting two DC generators in parallel
we equal voltage ratings. As the generator voltage is easily
adjustable in a range, so the condition stated above is not a
must. But, it is desirable condition.
1 of 5 3/19/18, 7:23 AM
DC Generator Parallel Operation Questions and... about:reader?url=https://www.sanfoundry.com/...
Answer: d
Explanation: Same voltage rating, same percentage voltage
regulation, same percentage speed regulation are the
desirable conditions for connecting two generators in
parallel, though these conditions are not a must.
Explanation: a
Answer: We connect two generators in parallel for supplying
large DC load. It is desirable to use more than one
generator in parallel. This arrangement provides the
security that if one generator gives way, the other(s) can
feed part load.
2 of 5 3/19/18, 7:23 AM
DC Generator Parallel Operation Questions and... about:reader?url=https://www.sanfoundry.com/...
Answer: b
Explanation: Two generators are connected in parallel such
that, summation of current carried by both generators is
equal to load current. In such cases we need to see
external characteristics on loaded condition.
Answer: c
Explanation: The load sharing by these generators is
determined by addition of external characteristics of both of
generators. Thus, at no load generators will have common
point, on y- axis so parallel characteristic will start from
same point and will lie above of both.
3 of 5 3/19/18, 7:23 AM
DC Generator Parallel Operation Questions and... about:reader?url=https://www.sanfoundry.com/...
View Answer
Answer: d
Explanation: If load current in G1 increases, load current in
G2 decreases. Series excitation and internal voltage in G1
increases and for G2, these quantities decrease. Finally, all
load shifts, which may turn to run G2 as a motor. All this
leads to heavy overloading of G1.
Answer: a
Explanation: A low-resistance equalizer connection is made
directly between the two armatures before the series fields.
Any emf variations of the armatures causes equalizing
circulating current which do not affect the current through
the series windings. Thereby the parallel operation is
stabilized.
4 of 5 3/19/18, 7:23 AM
DC Generator Parallel Operation Questions and... about:reader?url=https://www.sanfoundry.com/...
Answer: a
Explanation: When two DC series motor are connected in
parallel then the resultant speed is increase the normal
speed. If the voltage across each motor is assumed to be
V, then current through each motor in parallel connection
will be I/2. So, speed α (voltage/current) α (V/Ia/2). Hence
the resultant speed is more than normal speed.
5 of 5 3/19/18, 7:23 AM