0% found this document useful (0 votes)
186 views2 pages

Motor S51 Code Supplement PDF

The document provides information for generating a model code for a Series 51 variable motor. The model code consists of a series of options that specify characteristics like mounting flange type, displacement size, shaft configuration, control type, and more. Control options include two-position controls, pressure compensator controls, and proportional controls. Each control type has a corresponding set of allowable additional control options that further define the control characteristics.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
186 views2 pages

Motor S51 Code Supplement PDF

The document provides information for generating a model code for a Series 51 variable motor. The model code consists of a series of options that specify characteristics like mounting flange type, displacement size, shaft configuration, control type, and more. Control options include two-position controls, pressure compensator controls, and proportional controls. Each control type has a corresponding set of allowable additional control options that further define the control characteristics.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

saue

Series 51 Model Code Supplement

Model Code
A specific model can be designated by generating a modular Model Code. The Model Code must be designated
in the sequence shown here. LEGEND:
● = Standard
❍ = Optional
- = Not Available
R Frame G L F M N J S T W Y P K V Z
5 1 A A

Frame Size and Flange PRODUCT


080C

110C
080V

110V

160V

250V

51 = Series 51 Variable Motor

R: MOUNTING FLANGE & ROTATION


● - ● - ● ● V = SAE Flange, Bidirectional
- ● - ● - - C = Cartridge Flange, Bidirectional

D: DISPLACEMENT
● ● - - - - 080 = 80.7 cm3/rev (4.92 in3/rev)
- - ● ● - - 110 = 109.9 cm3/rev (6.71 in3/rev)
- - - - ● - 160 = 160.9 cm3/rev (9.82 in3/rev)
- - - - - ● 250 = 250.0 cm3/rev (15.26 in3/rev)

G: END CAP PORTING (SAE J518c Code 62/61) Code 61 w Split Flange
❍ ❍ ❍ ❍ ❍ ❍ A = Axial Ports, Loop Flushing, Code 62
❍ ❍ ❍ ❍ ❍ - B = Axial Ports, Loop Flushing, Code 61
● ● ● ● ● ● R = Side Ports, Loop Flushing, Code 62
❍ ❍ ❍ ❍ ❍ - S = Side Ports, Loop Flushing, Code 61

L: SHAFT CONFIGURATION
● - - - - - S1 = 14T, 12/24P Spline
❍ - - - - - C7 = 23T, 16/32P Spline
- - ❍ - ❍ - C8 = 27T, 16/32P Spline
- - ● - ● - F1 = 13T, 8/16P Spline
- - - - - ● F2 = 15T, 8/16P Spline
- ● - - - - D2 = W35 x 2 x 16 x 9g per ISO 5480
- ❍ - ● - - D3 = W40 x 2 x 18 x 9g per ISO 5480
- - - ❍ - - D4 = W45 x 2 x 21 x 9g per ISO 5480

F: MAXIMUM DISPLACEMENT
● ● ● ● ● ● N = 100%
❍ ❍ ❍ ❍ ❍ ❍ Consult Factory for Acceptable Settings Less Than 100%

W: SPECIAL HARDWARE FEATURES


● ● ● ● ● ● NNN = None
❍ - - - - - FAB = Slotted Flange
❍ ❍ ❍ ❍ ❍ ❍ ACA = Speed Sensor

Y: MINIMUM DISPLACEMENT SETTING


Specify in 1 cm3/rev Increments as follows:
● ● - - - - 016 to 054 cm3/rev
- - ● ● - - 022 to 074 cm3/rev
- - - - ● - 032 to 115 cm3/rev
- - - - - ● 050 to 168 cm3/rev

P: NOT USED
● ● ● ● ● ● AA = Default

K: CHARGE PRESSURE SETTING


● ● ● ● ● ● 2 Digits in Full Bar Increments (Typically 2 bar less than pump setting)
Example: 22 = 22 bar (320 psi); Acceptable Range: 10 to 30 bar (=145 to 435 psi)
❍ ❍ ❍ ❍ ❍ ❍ 99 = Charge Relief Valve Defeated

A-1
saue
Series 51 Model Code Supplement

Model Code: Control Options


There are three types of controls available with Series 51 Variable Motors: two-position controls, pressure
compensator controls, and proportional controls. Choose codes from the appropriate tables below.

For acceptable control options to follow a given M control type, choose subsequent options that fall within the solid
horizontal lines above and below the row of the given M selection. See example below table.

R Frame G L F M N J S T W Y P K V Z
5 1

TWO-POSITION CONTROLS
M:CONTROL TYPE N: SERVO SUPPLY* T: ORIFICE J: THRESHOLD RANGE S: RAMP V: START POINT Z: PCOR SETTING
HZ: Hydraulic 2-Pos Control , > 45 psid→Min ∠ B1: Std G0: Std A: 2~5 bar N: None 03: Std 00: None
E1: EH 2-Pos Control, 12V, On=Min ∠ A5: Std K7: Slow
E2: EH 2-Pos Control, 24V, On=Min ∠
F1: EH 2-Pos Control, 12V, On=Max ∠
F2: EH 2-Pos Control, 24V, On=Max ∠

PRESSURE COMPENSATOR (PC) CONTROLS


M:CONTROL TYPE N: PC PORT & BPD* T: ORIFICE J: THRESHOLD RANGE S: RAMP V: START POINT Z: PC SETTING
TA: Pressure Compensator (PC) Control C0: Ports A & B, w BPD G0: Std L: 110~370 bar N: None 00: Std A1~A9: 110~190 bar
TH: PC Control, Hyd OR to Max ∠ C2: Ports A & B, w/o BPD K7: Slow B0~B9: 200~290 bar
T1: PC Control, Elect OR to Max ∠, 12V R5: Port A, w/o BPD C0~C7: 300~370 bar
T2: PC Control, Elect OR to Max ∠, 24V L5: Port B, w/o BPD

PROPORTIONAL CONTROLS
M: CONTROL TYPE N: PCOR PORT & BPD* -- →T: ORIFICE J: THRESHOLD RANGE S: RAMP V: START POINT Z: PCOR SETTING
HZ: Hydraulic Prop Control (1-line) B1: N/A ------------------------- →G5 A: 2~5 bar E: 7 bar 2 Digit in 1 bar 00: N/A
JA: Hydraulic Automotive Control (250cc N/A) NN: N/A ------------------------- →K3 B: 5~12 bar H: 14 bar Increments 11~37: 110~370 bar
HS: Hydraulic Prop Control (1-line) A1: Ports A & B, w BPD ----- →G7 C: 12~50 bar G: 21 bar Must fall in J:
K1: Hyd Prop Control, 12V Electric Max ∠ OR A2: Ports A & B, w/o BPD -- →G6 range
K2: Hyd Prop Control, 24V Electric Max ∠ OR R2: Port A, w/o BPD --------- →G8 e.g.: 06 = 6 bar
HP: Hydraulic Prop (2-line), Shuttle Valve L2: Port B, w/o BPD --------- →G9 G: 3~5 bar D: 7 bar
H: 5~8 bar
L1: EH Prop Control, 12V B1: N/A ------------------------- →G5 W:440 mA B: 850 mA D4: 440 mA 00: N/A
L2: EH Prop Control, 24V V: 220 mA A: 425 mA B2: 220 mA
EP: EH Prop, Packard Conn, Ext PCP supply A1: Ports A & B, w BPD ----- →G7 J: 15~50 mA U: 50 mA 2 Digit in 5 mA 11~37: 110~370 bar
EQ: EH Prop, MS Conn, Ext PCP supply A2: Ports A & B, w/o BPD -- →G6 K: 50~85 mA Y: 70 mA Increments 00: N/A for N: = A5
ER: EH Prop, Packard Conn, Int PCP supply R2: Port A, w/o BPD --------- →G8 Z: 95 mA e.g.: 30 = 30 mA
ES: EH Prop, MS Conn, Int PCP supply L2: Port B, w/o BPD --------- →G9
A5: None ------------------------ →G5
For Proportional Controls
each N option has one
corresponding T option.

*Internal servo pressure supply is standard, consult factory for external servo supply options
ABBREVIATIONS:
Control model code example EH = Electrohydraulic
Elec = Electric
For M: = K1, the following choices are available: Hyd = Hydraulic
Prop = Proportional
N: = A1, A2, R2, or L2 BPD = Brake Pressure Defeat
T: = G7, G6, G8, or G9 (corresponds to N:); PC = Pressure Compensator
OR = Override
J: = A, B, or C; PCOR= Pressure Compensator Override
S: = E, H, or G; Pos = Position
Std = Standard
V: = 2 digit in bars (within J: range); Int = Internal
Z: = 2 digit in bars (11, 12, 13,..., or 37) Ext = External
PCP = Pilot Control Pressure
MS = Military Specification (Connector)

A-2 BLN-10042 Supplement • March 1997