Issued January 2018 • Index No. ED/4.

33

Bobcat 3 Phase Gas Engine-Driven


Welder/AC Generator

Applications Processes Output Range


Generator power for: Stick (SMAW) Stick/TIG 40 – 225 A MIG/flux-cored (CV) 19 – 28 V
Farm or home backup MIG (GMAW)
Generator Power Output Rated at 104°F (40°C)
Quick Pivot irrigation systems
Pumps
Flux-cored (FCAW)
DC TIG (GTAW) 3-Phase: 11,000 watts peak, 10,000 watts continuous
1-Phase: 11,000 watts peak, 9,500 watts continuous
Specs Conveyors Non-critical AC TIG (GTAW)
Air plasma cutting and gouging
Welding: Net Weight 495 lb. (225 kg)
Farm equipment repair with optional Spectrum models
General maintenance
Fabrication

For farm and ranch owners in need of single- and three-phase power.
Designed to run 480-volt three-phase pivot irrigation systems or to
provide backup power for home, farm and ranch.

Quieter S and
f better sound compared
Designed for reliability. From Appleton, to previous model. Significant improve-
Wis. USA, our welder/generators are the ments in sound level and quality offer
most rugged, durable and long-lasting in the better jobsite communication, which
industry. We manufacture them to exceed provides a safer, more efficient working
requirements for extreme working conditions environment for you and your crew.
and they are hard-working from the core: Bobcat welder/generators have rotated
• Copper windings and iron generator the engine toward the front to create
components for a quality-built machine more efficient airflow, resulting in signi-
• Lugged — not soldered — heavy internal ficantly quieter operation. Now you can
leads for better field durability start your job earlier in the day and end
• Superior cooling technology for it later, as well as work around hospitals,
maximum performance and engine life businesses, and residential areas.
• Super-tough armor to protect the
welder/generator from accidental impact
• Protective armor doors to cover the weld
studs and receptacles as required by
OSHA and CSA for jobsite safety
• Lift hook integrated into the center frame,
which bolts to the machine’s base for
greater durability Easier maintenance compared to previous model. With
its intuitive design, the daily maintenance of our Bobcat Smaller and lighter design compared
Long runtimes. Large 12-gallon fuel welder/generators is faster and easier. With front panel to previous model. Bobcat welder/
capacity means many hours of run time maintenance displays, you know when your equipment generators take up less space on trucks
before refueling. needs to be serviced. And servicing is simple because of: and trailers — leaving more room on
Versatile AC and DC weld output. • Oil checks that can be performed from the top by the your truck for other equipment and
Provides quality welds on all types of front panel tools. Plus, they’re easier to move safely
metals. DC is smooth and easy to run while • Toolless panels that allow for quick access around jobsites — even with weld cables
AC stick is used when arc blow occurs. • Single-side fuel fill and oil drain/filter and running gear attached.

Welder/generator is warranted for three years, parts and labor.


Engine is warranted separately by the engine manufacturer.

Miller Electric Mfg. LLC Equipment Sales US and Canada MillerWelds.com


An ITW Welding Company Phone: 866-931-9730
1635 West Spencer Street FAX: 800-637-2315
P.O. Box 1079 International Phone: 920-735-4554
Appleton, WI 54912-1079 USA International FAX: 920-735-4125
The Bobcat Advantage ™

Reversed generator flow


Exclusive engine and generator packaging design operates cooler and
more efficiently. The engine is rotated towards the front to create more
efficient airflow. More efficient airflow and exclusive engine location
are significant contributors to reduced sound level and size reduction.
Hot air recirculation is eliminated when machine is mounted in tight
spots, and internal parts are kept cool for optimal performance.

The Bobcat Generator Power Advantage ™


Accu-Rated — not inflated generator power Typical equipment power usage
Our Accu-Rated™ 11,000 watts of usable peak power is delivered for a minimum Bobcat welder/generators will easily start and run
of 30 seconds. Accu-Rated means peak power is usable for maximum generator the following equipment:
loads such as plasma cutting, Millermatic® MIG welders and motor starting.
Accu-Rated peak power beats the competition’s very short-duration peak or surge Starting Running
Equipment Watts Watts
power. Use your peak power, it’s more than a number.
Barn Cleaner (5 hp) 11,600 3,000
Silo Unloader (5 hp) 12,200 4,300
Bobcat Portable Conveyor (1/2 hp) 3,400 1,000
Milker (5 hp) 10,500 2,800
Hand Drill (1/2 inch) 600 600
Circular Saw (8-1/4 inch) 1,400 1,400
Air Compressor (1-1/2 hp) 8,200 2,200
Flood Lights (Vapor) 1,250 1,000
Competitor
Smooth power — not spike power Refrigerator/Freezer 2,200 700
Revolutionary ten-degree skewed-rotor design Sump Pump 1,300 800
optimizes generator performance for smoother Millermatic® 212 Auto-Set™ 6,500 6,500
power — not spiked power found with other brands. MIG Welder (230 V)
Better power — better performance. Waveform Comparison Spectrum® 625 X-TREME™ 6,900 6,900
(30 A, 230 V, 1/2-inch cut)
Generator Power Curve
300 150 To select a generator that has enough power output
264 132 in watts, add the watts for the items you want to
250 125
216 108
simultaneously run. Tools and appliances with induction
200 100 motors may require three to seven times the listed wattage
AC Power Volts

150 75 when starting. All data listed is approximate — check


your tool/appliance for specific wattage requirements.
100 50
50 25

0 0
0 20 40 60 80 100 120 140 160 180 200 220
AC Power Amps at 120 V

0 10 20 30 40 50 60 70 80 90 100 110
AC Power Amps at 240 V
Tools and motors are designed to operate within 10 percent of 120/240 V. The power
generator of the Bobcat provides strong power while keeping the voltage within 10 percent of
120/240 V. This increases tool/motor performance and life.

2
Specifications (Subject to change without notice.)
Rated Output Sound Levels
Welding Amp/Volt at 100% Duty Cycle at Max. Load/ Net
Mode Process Ranges (at 104°F/40°C)* Generator Power at 150 Amps Dimensions Weight**
CC/AC Stick/TIG 40 – 225 A 200 A at 25 V Single-phase Three-phase 73.5 dB/72 dB H: 28 in. (711 mm) 495 lb.
Peak: 11,000 watts Peak: 11,000 watts H: 32.75 in. (832 mm) (225 kg)
CC/DC Stick/TIG 40 – 210 A 210 A at 25 V Continuous: 9,500 watts Continuous: 10,000 watts (to top of exhaust)
120/240 V, 84/42 A 480 V, 13 A W: 20 in. (508 mm)
CV/DC MIG/FCAW 19 – 28 V 200 A at 20 V
D: 40.5 in. (1,029 mm)

*Rated at sea level. **Net weight without fuel. Certified by Canadian Standards Association to both the Canadian and U.S. Standards.

Engine Specifications (Engines warranted separately by the engine manufacturer.)


Engine Brand Weld Idle Fuel Oil Standard
and Warranty Horsepower (HP) Type Speed Speed Capacity Capacity Shutdowns
Kohler CH730, 23.5 hp at 3,600 rpm Twin-cylinder, four-cycle overhead 3,600 2,300 12 gal. 1.5 qt. Low oil
3-year warranty valve, industrial air-cooled, gasoline* rpm rpm (45 L) (1.4 L) pressure
*Fuel stabilizer is recommended for gas engines that are used infrequently.

Performance Data Mounting Specifications


Fuel Consumption
2.00 G 4 Holes
1-Phase
Fuel Consumption Data

Front Panel
1.75 Generator DC Weld/ • 12-gallon fuel capacity.
Power
1.50
3-Phase
Generator • On a typical job using 1/8-inch A B
U.S. Gal./hour

1.25
Power 7018 electrodes (125 A,
20% duty cycle) expect about C
1.00
3,750 rpm 20 hours of operation.
0.75
• Welding at 150 A, 40% duty
0.50 cycle uses approximately D
0.25
Idle 2,200 rpm
3/4 gallon per hour — E
about 16 hours of operation. F
0
0 25 50 75 100 125 150 175 200 225 250 • Under a continuous load of A. 20 in. (508 mm) E. 22.3 in. (566 mm)
Weld Amps at 100% Duty Cycle 4,000 watts of generator B. 16.5 in. (419 mm) F. 40.32 in. (1,024 mm)
power, the Bobcat would
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 C. 1.75 in. (44.5 mm) G. .406 in. (10.3 mm)
run for about 14 hours of
Power KVA at 100% Duty Cycle D. 5.12 in. (130 mm) diameter
operation.

Function and Benefit Guide


1. Maintenance display provides fuel level, engine hours and oil change
interval information.
1
2. Weld process selector switch makes choosing between stick, wire
and TIG processes easy. Switch also automatically changes polarity
2 with process selection to make sure the machine is easy to set with
3 little effort or knowledge.
4 3. Coarse range control. Three stick/TIG and one wire range are available
for output control. Stick/TIG ranges are designed to electrode diameters
(3/32, 1/8, and 5/32 inch) making these models very easy to set.
4. Fine adjust control makes it easy to fine tune amperage within a
coarse range. Set control above 7 for best power while welding and to
5 10 for generator-only use.
6 5. Engine control switch is used to start the engine and then select
between auto idle and high speed lock positions.
7 6. Engine choke control is used for easy engine starting.
7. 120/240 V receptacle with circuit breaker.
(For matching plug, order 119172.)
8 8. 480 V receptacle with circuit breaker.
(For matching plug, order 165963.)
9 9. 120 V GFCI receptacles with circuit breakers.

3
Genuine Miller Accessories (For additional options and accessories, see Bobcat literature ED/4.4)
®

GFCI Receptacles 300975 Field ™


Multi-Terrain Running Gear
Kit contains two GFCI 120 V duplex receptacles. Never Flat Tires 300913 w/inner tubes
Electric Fuel Pump 300976 Field Available on Bobcat and 300914 w/Never Flat tires
Recommended for gas engine operations at Trailblazer running gear. Includes two heavy-duty
altitudes above 5,000 feet. Improves engine • Eliminate costly jobsite 15-inch tires, two 8-inch
starting and high-output performance. downtime rubber swivel casters and a
• Maintain constant tire pressure and will heavy-duty handle. Recommended for all surfaces
Spark Arrestor 300924 Field not develop flats and applications.
Mandatory when operating on California grass- • Protect against punctures
lands, brush or forest-covered land, and all Protective Cage with Cable Holders 300921
• Preserve maneuverability, even when Rugged cage with cable holders protects your
national forests. For other areas, check your weighed down with heavy welding cable
state and local laws. investment. Can be used with running gear, gas
cylinder mounting assembly, or with trailer.
Full KVA Adapter Cord 300517 Field
Off-Road Running Gear Protective Covers
NEMA 14-50P to NEMA 6-50R. Adapts engine
300909 w/inner tubes 300919 For models without protective cage or
drive 120/240 V plug to common Millermatic®
300910 w/Never Flat tires running gear (shown)
and Spectrum® 240 V plug.
Includes four heavy-duty 300920 For models with protective cage and/or
Full KVA Plug 119172 Field 15-inch tires and a running gear
120/240 V, 50 A plug (NEMA 14-50P) to fit full rugged handle to provide Heavy-duty, water-resistant and mildew-resistant
KVA receptacle. maximum maneuverability. covers protect and maintain finish of the welder.
Full KVA 3-Phase Plug 165963 Field Off-Road Running Gear HWY-Mid Frame Trailer 301438
480 V, 30 A plug (NEMA L16-30P) to fit with Protective Cage and A 1,424-pound (646 kg) capacity highway trailer.
3-phase receptacle. Never Flat Tires 300912 Includes jack stand, fenders, lights, and dual
Engine Tune-Up Kit 230015 Field Running gear and rugged hitch with 2-inch (50 mm) ball hitch and 3-inch
Includes spark plugs and engine filters. cage with cable holders (76 mm) lunette eye. Shipped unassembled.
Order from Miller Service Parts. protects your investment
Cable Tree 043826
and is easy to move
SuitCase® X-TREME™ Wire Feeders Provides an area to conveniently wrap weld
around the jobsite.
See literature M/6.42. cables and extension cords.
Dynasty® 210 Series TIG Welders 2-In-1 Document/Fire Extinguisher Holder
See literature AD/4.81. 301236
Spectrum® Plasma Cutters Stores documents and holds a five-pound fire
See literature PC/9.2, PC/9.6 and PC/9.8. extinguisher.

Ordering Information
Equipment and Options Stock No. Description Qty. Price
Bobcat™ 3 Phase 907505 Kohler engine with GFCI receptacles
GFCI Receptacles 300975 Field
Electric Fuel Pump 300976 Field. Recommended for gas engine operations at altitudes above 5,000 feet
Spark Arrestor 300924 Field
Full KVA Adapter Cord 300517 Field
Full KVA Plug 119172 Field
Full KVA 3-Phase Plug 165963 Field
Engine Tune-Up Kits 230015 Field. For Kohler CH 730. Order from Miller Service Parts
MIG/Flux-cored/TIG Welding See above
Plasma Cutting See above
Accessories
Off-Road Running Gear See above
Multi-Terrain Running Gear See above
Protective Cage w/Cable Holders 300921
Protective Covers See above
HWY-Mid Frame Trailer and Accessories See above

Date: Total Quoted Price:

Distributed by:

© 2018 Miller Electric Mfg. LLC

You might also like