Blending Calculation

This document calculates the filling times for two blended gasoline tanks: - For RON 80, the filling time for light naphtha and reformate is 21.8 days using proposed pumps, but existing higher capacity pumps could reduce this. - For RON 95, the filling time for reformate and light naphtha is 8.2 days, and existing pumps are proposed to be used for blending.

Uploaded by

syamsudin2006
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views

Blending Calculation

This document calculates the filling times for two blended gasoline tanks: - For RON 80, the filling time for light naphtha and reformate is 21.8 days using proposed pumps, but existing higher capacity pumps could reduce this. - For RON 95, the filling time for reformate and light naphtha is 8.2 days, and existing pumps are proposed to be used for blending.

Uploaded by

syamsudin2006
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

FILLING TIME CALCULATION

A. Blended Gasoline RON 80
Blended Gasoline RON 80 Tank Capacity = 6000 m3
Light Naphtha Fraction = 52%
Reformate Fraction = 48%
Portion volume of Light Naptha = 3125 m3
Portion volume of Reformate = 2875 m3
Proposed LN blending pumps are  = 6.0 m3/hr min.= 4.7 m3/hr
Proposed reformate blending pumps are  = 5.5 m3/hr min.= 4.7 m3/hr
Result:
Filling time for Light Naphta = 21.8 days
Filling time for Reformate = 21.8 days
IKL propose:
The existing truck loading pumps P‐539 A/B (capacity 32 m3/hr) can be utilised as LN blending pumps
The existing truck loading pumps P‐537 A/B (capacity  32 m3/hr) can be utilised as reformate blending pumps
RO installed at discharge pump

B. Blended Gasoline RON 95
Blended Gasoline RON 95 Tank Capacity = 6000 m3
Reformate Fraction = 87%
Light Naphtha Fraction = 13%
Portion volume of Reformate = 5217 m3
Portion volume of Light Naptha = 783 m3
Proposed reformate blending pumps are  = 26.5 m3/hr min.= 4.7 m3/hr
Proposed LN blending pumps are  = 4.0 m3/hr min.= 3.3 m3/hr
Result:
Filling time for Reformate = 8.2 days
Filling time for Light Naphta = 8.2 days
IKL propose:
The existing MS RCFP pumps P‐511 A/B (capacity 20 m3/hr) can be utilised as LN blending pumps
The existing truck loading pumps P‐537 A/B (capacity 32 m3/hr) can be utilised as reformate blending pumps
RO installed at discharge pump