Activated Sludge Reactor Calculations Given Value Unit
The document provides calculations for an activated sludge reactor treating wastewater with an influent BOD5 of 0.13 kg/m3, including determining a reactor volume of 892.1568 m3, a recirculation ratio of 0.4233, and an organic loading of 0.7577 kg BOD5/m3-day. Secondary clarifier calculations are also shown for 3 tanks each with a volume of 14521.7333 ft3, a depth of 11.1408 ft, and a width of 18.0518 ft to handle the total flow of 1955206.175 gal/day with an overflow rate of 500 gal
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
165 views2 pages
Activated Sludge Reactor Calculations Given Value Unit
The document provides calculations for an activated sludge reactor treating wastewater with an influent BOD5 of 0.13 kg/m3, including determining a reactor volume of 892.1568 m3, a recirculation ratio of 0.4233, and an organic loading of 0.7577 kg BOD5/m3-day. Secondary clarifier calculations are also shown for 3 tanks each with a volume of 14521.7333 ft3, a depth of 11.1408 ft, and a width of 18.0518 ft to handle the total flow of 1955206.175 gal/day with an overflow rate of 500 gal
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2
ACTIVATED SLUDGE REACTOR CALCULATIONS
GIVEN VALUE UNIT
influent BOD5, So 0.13 kg/m3 Effluent BOD5, S 0.005 kg/m3 Flowrate, Qo 5200 m3/day Y 0.5 kg/kg kd 0.05 /day MLSS, X 3 kg/m3 Recycle, Xr 10 kg/m3 Mean Cell Residence Time, Z 14 day PARAMETERS REACTOR VOLUME, Vr 892.1568627451 m3 VOLUME OF EXCESS SOLIDS, Qw 19.1176470588 m3/day MASS OF EXCESS SOLIDS 191.1764705882 kg/day Qr 2201.260504202 kg/day RECIRCULATION RATIO, R 0.4233193277 OPERATING CONDITIONS AERATION TIME, t 4.1176470588 hr ORGANIC LOADING, OL 0.7577142857 kg BOD5/m3-day F/M 0.2525714286 kg BOD5/ kg MLSS day BOD REMOVAL EFFICIENCY 96.1538461538 % SECONDARY CLARIFIER TANK CALCULATIONS
PARAMETERS VALUE UNIT
TOTAL FLOW, Q 1955206.175 gal/day FLOW IN ONE TANK (n=3 tanks), Qc 651735.3916667 gal/day OVERFLOW RATE 500 gal/day-ft2 SURFACE AREA, A 1303.470783333 ft2 DETENTION TIME-Automatic sludge removal 4 hr VOLUME, V 14521.73332591 ft3 DEPTH, d 11.1408199643 ft WIDTH, w 18.0518058884 ft LENGTH, l 72.2072235537 ft CROSS-SECTIONAL AREA, Ax 201.1119194343 ft2 FLOW THROUGH VELOCITY, Vf 0.3007332659 ft/min WEIR LENGTH, Lw 43.4490261111 ft