0% found this document useful (0 votes)
113 views17 pages

Electric Heaters, Reactor and Flashdrum

The document provides design specifications for equipment used in an ethanol production process, including: 1. An ethanol heater with a power rating of 221.76 kW and 3 heating elements. 2. An air heater with a power rating of 240.42 kW, 3 heating elements, and a 450m long duct with a width of 0.45m. 3. An oxidation reactor with a bed diameter of 0.693374m, bed length of 9.975m, and an internal pressure of 58.84psi.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
113 views17 pages

Electric Heaters, Reactor and Flashdrum

The document provides design specifications for equipment used in an ethanol production process, including: 1. An ethanol heater with a power rating of 221.76 kW and 3 heating elements. 2. An air heater with a power rating of 240.42 kW, 3 heating elements, and a 450m long duct with a width of 0.45m. 3. An oxidation reactor with a bed diameter of 0.693374m, bed length of 9.975m, and an internal pressure of 58.84psi.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 17

Equipment: Ethanol heater

Equipment Code: EH-01

Type: Screw Plug Immersion Heater

Data and Assumptions:

1. Heat requirement is 4790193.921 kJ (From Energy Balance)


2. Heat efficiency is 75%
Design Requirements:

1. Power rating
2. Watt Density
3. Number of Elements
4. Sheath Material
5. Screw Plug Material
6. Immersed length
Design Calculation:

Solving for Total Power Rating:

4790193.921 kJ 1 hour 1
Power rating= × ×
8 hour 3600 sec 0.75
Power rating= 221.76 kW

Solving for Number of Elements:

Using 100 KW Power rating per heater:

221.76 kW
Elements =
100 kW/Heater
Elements = 2.2 or 3 Elements

To compute for the design of the electric heater’s cubic vessel with 10% volumetric allowance,

Mass of Feed: 6212.064197 kg

Density of Feed: 785.7193513 kg/m3


6212.064197
Theorical Volume: = 7.91 𝑚3
785.7193513

Actual Volume: 7.91 𝑚3 × 1.25 = 9.85 𝑚3


𝑉 = 𝑆3

9.85 = 𝑆 3

𝑆 = 3.138 𝑚 ≅ 3.2 𝑚

Specification Summary:

Equipment EH-01
Total Power Rating 221.76 kW
Number of Elements 3
Voltage 600 V
Screw Plug Size 3 in
Pressure rating 300 psig
Screw Plug Material Carbon Steel
Immersed Length 130 in
Sheath Material Incoloy Steel
Watt Density 75 watts per square inch
Cubic Vessel’s Edge 3.2 m
Equipment: Air heater

Equipment Code: EH-02

Type: Screw Plug Immersion Heater

Data and Assumptions:

1. Heat duty is 5193027.619 kJ (From Energy Balance)


2. Heat Efficiency 75%
Design Requirements:

1. Power rating
2. Watt Density
3. Number of Elements
4. Sheath Material
5. Screw Plug Material
6. Immersed length

Design Calculation:

Solving for Total Power Rating:

5193027.619 kJ 1 hour 1
Power rating= × ×
8 hour 3600 sec 0.75
Power rating= 240.42 kW

Solving for Number of Heaters in Series:

Using 100 KW Power rating per heater:

240.42 kW
Number of Elements=
100 KW/Heater
Elements= 2.4042 or 3 heaters in series

To compute for the Air duct design:

Air velocity (𝜐) = 1.5 m/s

Mass of air = 24200.04139 kg/shift


Volume of air:

P= 4 atm

T= 513 K
19118.0327 5082.008692
( 28
+ 32
)×0.08205×513 𝐾
V=
4

V= 8856.079 m3

8856.079 m3
Q=
8×3600 𝑠

Q = 0.3075 m3/s

Solving for Duct Cross-sectional Area:

𝑄
A=
𝜐

0.3075 m3/s
A=
1.5 𝑚/𝑠

Solving for Duct Width:

A= 0.205 𝑚2 W

𝑊2 = 𝐴

𝑊 2 = 0.205 𝑚2

𝑾 = 0.452 m

Solving for Duct Length:

For 5 minutes residence time,

𝑚 60 𝑠
L = 1.5 × × 5 𝑚𝑖𝑛𝑠
𝑠 1 𝑚𝑖𝑛
𝑳 = 450 m
Specification Summary:

Equipment EH-02
Total Power Rating 240.42 kW
Number of Elements 3
Voltage 600 V
Screw Plug Size 3 in
Pressure rating 300 psig
Screw Plug Material Carbon Steel
Immersed Length 130 in
Sheath Material Incoloy Steel
Watt Density 75 watts per square inch
Air velocity in duct 1.5 m/s
Duct Width 0.45 m
Duct Length 450 m
Equipment: Oxidation Reactor

Equipment Code: OR-01

Type: Vertical tubular reactor

Data and Assumptions:

1. Adiabatic operation
2. Flat velocity profile
3. No axial dispersion
4. No radial dispersion
5. Pseudo-homogeneous assumption
6. Bed void fraction (ε) is 0.375
7. Space time is 8 hours

Design Requirements:

1. Bed Diameter
2. Bed Length
3. Reactor Length
4. Shell Thickness
5. Head Thickness

Reactor composition:

Components Input Output


Ethanol 6087.822913 60.87822913
Water 124.2412839 2482.610943
Nitrogen 19118.0327 19118.0327
Oxygen 5082.008692 1146.361406
Acetaldehyde - 706.7771826
Acetic Acid - 6897.445129
Total 30412.10559 30412.10559

Operating temperature = 513 K

Operating Pressure = 4 atm

Activity= 200 g ethanol/l-catalyst-hr


Thermal Properties of Feed:

Density (ρ) = 3.101336866 kg/m3

Viscosity (μ) = 0.00002455293 Pa-s

Bed void fraction (ε) = 0.375 for close random packing, monodispersed, (Dullien, 1992)

Solving for Actual Bed Diameter( Db) by Ergun Equation:

μν (1-ε)2 ρν2 (1-ε)


∆P=150 { × [ ]} +175 { × [ 3 ]}
D2 ε3 D ε

Initially assume ∆P’ and D,

Pressure drop (∆P’) = 3480 Pa/m (average pressure drop in Packed-bed)

Bed Diameter (D) = 4.11 m (Maximum diameter of Packed-bed reactors)

0.00002455293 ν (1-0.375 )2 3.101336866 ν2 (1-0.375 )


3480=150 { × [ ]} +175 { ×[ ]}
4.112 0.375 3 4.11 0.375 3

3480 = 1.615 × 10−3 ν + 1565.0614 ν2

v= 1.49117 m/s

Solving for Reactor Diameter:

Volumetric flowrate, Vv;

Average molecular wt. = 32.63


30412.10559
( ) × 0.08205 × 513 K
32.63
Volume =
4 atm
Volume = 9807.659 m3

9807.659 m3 1 hour
Vv = × =0.340504 m3/sec
8 hour 3600 sec
Bed Area, A

0.340504 m3/sec
A= = 0.22837 m2
1.49117 m/s
Bed Diameter, D

4×0.22837 m2
D=√ = 0.5392 m (1.769 ft.)
3.1416

Use Step 8 on Table 7.1 Chemical Process Engineering Design and Economics by Silla, D is less
than 30 in (0.762 m), round off the diameter to 2.2748 ft (0.693374 m).

Solving for Actual Bed Area, Ab;


2
3.1416 × 0.6933742 m
Ab= = 0.377595 m2
4
Solving for Actual Superficial Velocity, νs;

0.340504 m3/sec
νs = = 0.90177 m/s
0.377595 m2

Solving for Bed length (Lb);

Vc
Lb=
Ab
Where:

Vc = Volume of Catalyst

Ab = Actual Bed Area

Solving for the volume of the catalyst;

6026.944 kg EtOH 1 L Catalyst 1m3


Vc = × ×
8 hours 0.200 kg/h HAc 1000L

Vc = 3.76684 m3
3.76684 m3
Lb= = 9.975 m
0.377595 m2

Solving for internal pressure;

PAbs =ρgh+Patm

PAbs =(3.101336866 × 9.81× 10.0403) + 405300 Pa

PAbs =405605.4340 Pa = 58.84 psi

For allowable working stress:

S=Su×Fm×Fa×Fr×Fs

Where:

S= allowable working stress


Su= Ultimate tensile strength
Fm= Material Factor
Fa= Radiograph factor
Fr= Stress relieving factor
Fs= Allowable factor for safety

Su = 55000 psi

S=55000×1.0×1.0×0.25

S=13750 psi

Solving for Shell thickness:

PD
ts = +C
2Se-P

Where:

ts = shell thickness
P = working pressure
D = diameter
S = allowable stress
e = efficiency
C = corrosion allowance; (min C = 1/16)

(58.84)(21.228) 1
ts = +
2(13750)(1.0)-58.84 16

ts =0.108 in

Head is Toroispherical since operating pressure is less than 150 psig.

Solving for Toroispherical Head thickness:

1.104PD
th = + C
2eS-0.2P
1.104 × 58.84×21.228 1
th = +
2(13750)(1.0)-0.2× 58.84 16

th = 0.11266 in

For depth of toroispherical head

d = .25D

d=.25(21.228) = 5.307 in

d= 0.1348 m

Solving for Reactor Length (Lr);

Lr = Lb + d

Lr = 9.975 m + 0.1348 m

Lr = 10.1098 m
Specification Summary:

Equipment Oxidation Reactor


Materials of Construction Carbon steel (S42; Graded A)
Temperature 513 K
Mass 30608.74947 kg/shift
Pressure: 4.5 atm
Bed Length: 10 m
Bed Diameter: 0.7 m
Nominal Shell Thickness: 3/16 in.
Nominal Head Thickness: 3/16 in.
Corrosion Allowance: 1/16
Depth of Head 0.17333976 m

Specification Illustration:
Equipment: Flash Drum

Equipment Code: FD-01

Type: Vertical Gas-Liquid separator with Mesh Eliminator and Vortex Breaker

Data and Assumptions:

1. 99.9999% separation for gas and liquid phase


2. 2 batch/shift
3. Surge time is 10 minutes
Design Requirements:

1. Separator Diameter
2. Separator Height
3. Liquid Height
4. Mist Eliminator Thickness
Operating Parameters:

Operating temperature = 313 K

Operating Pressure = 1.00 atm

Solving for superficial velocity (ν);

Physical properties:

Density of Vapor, ρv = 1.098519665 kg/m3

Density of Liquid, ρL= 1016.99552 kg/m3

From Table 6.9, Chemical Process Engineering Design and Economics by Silla;

ρL-ρv
ν =kv√
ρv

kv = 0.107 m/s (With mist eliminator)

1016.99552 − 1.098519665
ν = 0.107 m/s √
1.098519665

ν = 3.25 m/s
Solving for Cross-sectional Area (A);

Volumetric Flowrate, Vv
2481.369637 20264.39411
( 1016.99552 + 1.098519665) 1 hour
Vv= ×
2 3600 seconds
Vv= 2.5624 m3/s

Solving for Cross- sectional area of Separator (As)

2.5624 m3/s
As=
3.25 m/s
As= 0.78884 m2

Solving for Separator Diameter (Ds)

4 × 0.78884 m2
Ds= √ = 1.0019 m
3.1416

Use Step 8 on Table 7.1 Chemical Process Engineering Design and Economics by Silla, D is
greater than 30 in (0.762 m), round off the diameter to 4 ft (1.2192 m).

Liquid phase surge time (ts) = 5 min

3.1416 × 1.21922
Actual Cross-sectional Area= = 1.167 m2
4

Solving for Liquid height in Separator (Ls);

2481.369637 kg 1 m3
Liquid Volume (Lv) = ×
3600 sec 1016.99552 kg

Liquid Volume (Lv) = 0.000677 m3/s


m3 60 sec
0.000677 s
× 10 min × 1 min
Liquid Height (HL) =
1.167 m2
Liquid Height (HL) = 0.34846 m

From Chemical Process Engineering Design and Economics by Silla

Settling Length (HS) = 1.5D

Settling Length (HS) = 1.5 × 1.005 m = 1.5075 m

Mist eliminator thickness (MT) = 0.152 mφ

Vapor Space (VS) = 0.305 m

For depth of toroispherical head

d = .25D

d=.25(1.005 m)

d= 0.25125 m

Solving for Total Separator Height (H):

H = HL + HS + MT + VS + d

H = 0.34846 m + 1.5075 m +0.152 m +0.305 m + 0.25125 m

H = 2.564 m

Solving for internal pressure;

PAbs =ρgh+Patm

PAbs =(560.71 × 9.81× 2.564) + 202650 Pa

PAbs =216753.47 Pa = 31.45 psi

φ Typical height for mist eliminator according to Silla is 6 in or 0.152 m


For allowable working stress:

S=Su×Fm×Fa×Fr×Fs

Where:

S= allowable working stress


Su= Ultimate tensile strength
Fm= Material Factor
Fa= Radiograph factor
Fr= Stress relieving factor
Fs= Allowable factor for safety

Su = 55000 psi

S=55000×1.0×1.0×0.25

S=13750 psi

Solving for Shell thickness:

PD
ts = +C
2Se-P

Where:

ts = shell thickness
P = working pressure
D = diameter
S = allowable stress
e = efficiency
C = corrosion allowance; (min C = 1/16)

(31.45 )(72) 1
ts = +
2(13750)(1.0)-31.45 16

ts =0.1449 in
Head is Toroispherical since operating pressure is less than 150 psig.

Solving for Toroispherical Head thickness:

1.104PD
th = + C
2eS-0.2P
1.104 × 31.45×72 1
th = +
2(13750)(1.0)-0.2× 31.45 16

th = 0.1534 in
Design Specification:

Equipment Code FD-01


Materials of Construction Carbon steel (S42; Graded A)
Temperature 313.15 K
Mass 30608.74947 kg/shift
Pressure: 1 atm
Height: 2.6 m
Diameter: 1.2192 m or 6 ft
Shell Thickness: 0.1449 in
Head Thickness: 0.1534 in
Nominal Shell Thickness: 3/16 in.
Nominal Head Thickness: 3/16 in.
Liquid Height 0.35 m
Mist eliminator Thickness 0.152 m or 6 in